Fire Sprinkler System Inspection
Maintain fire protection compliance with our NFPA 25 fire sprinkler system inspection checklist. Covers wet, dry, pre-action, and deluge systems.
Overview
This fire sprinkler system inspection checklist ensures compliance with NFPA 25 standards for commercial fire protection systems. Regular inspections verify system readiness, prevent malfunctions, and maintain insurance and code compliance for life safety.
Key Benefits
Streamlined Operations
Standardize your service workflows with professional templates that ensure consistency across all jobs and technicians.
Faster Job Completion
Pre-built checklists and forms help technicians complete jobs more efficiently, reducing time on-site and increasing daily job capacity.
Improved Compliance
Built-in safety checks and compliance requirements help you meet industry standards and reduce liability risks.
Better Customer Experience
Professional documentation and clear communication templates enhance customer trust and satisfaction.
Reduced Errors
Structured templates minimize missed steps and ensure all critical information is captured accurately every time.
Easy Customization
Adapt templates to your specific business needs with customizable fields, branding options, and workflow modifications.
Complete Checklist
- Verify all control valves are open
- Check valve position indicators
- Inspect valve accessibility
- Test tamper switches operation
- Check valve stem packing for leaks
- Verify proper valve identification
- Inspect gate and butterfly valves
- Check valve supervisory signals
- Test OS&Y valve operation
- Record gauge pressure readings
- Inspect sprinkler heads for damage
- Check for proper clearance around heads
- Verify correct head orientation
- Check for corrosion or loading
- Verify proper head spacing
- Check for painting or foreign material
- Inspect for signs of leakage
- Verify correct temperature ratings
- Check head replacement dates
- Inspect decorative covers if present
- Inspect exposed piping for damage
- Check pipe hangers and supports
- Verify proper pipe pitch in dry systems
- Check for signs of leakage
- Inspect pipe connections
- Verify proper drainage provisions
- Check for corrosion on pipe exterior
- Inspect seismic bracing if required
- Verify auxiliary drains
- Check for improper modifications
- Test water flow alarm operation
- Check alarm bell or horn audibility
- Test pressure switches
- Verify proper alarm signaling
- Check alarm device batteries
- Test supervisory signals
- Verify alarm transmission to monitoring
- Check retarding chamber if present
- Test air pressure switches
- Verify alarm reset operation
- Check fire pump controller status
- Verify power supply to pump
- Test pump starting automatically
- Check pump discharge pressure
- Inspect pump packing glands
- Verify proper pump rotation
- Test pump jockey operation
- Check diesel fuel level if applicable
- Inspect pump suction conditions
- Review pump operation logs
- Test antifreeze solution concentration
- Check for signs of leakage in loops
- Verify proper antifreeze level
- Inspect dry pipe valve
- Test air compressor operation
- Check air pressure in dry system
- Inspect low air pressure alarms
- Test quick-opening device
- Check accelerator or exhauster
- Verify proper drainage of dry system