Lightning Protection Inspection
Protect buildings from lightning strikes with our NFPA 780 inspection checklist. Covers air terminals, conductors, grounding, and surge protection devices.
Overview
This lightning protection system inspection checklist ensures compliance with NFPA 780 standards. Regular inspection of air terminals, down conductors, bonding, and grounding maintains effective lightning protection for commercial buildings.
Key Benefits
Streamlined Operations
Standardize your service workflows with professional templates that ensure consistency across all jobs and technicians.
Faster Job Completion
Pre-built checklists and forms help technicians complete jobs more efficiently, reducing time on-site and increasing daily job capacity.
Improved Compliance
Built-in safety checks and compliance requirements help you meet industry standards and reduce liability risks.
Better Customer Experience
Professional documentation and clear communication templates enhance customer trust and satisfaction.
Reduced Errors
Structured templates minimize missed steps and ensure all critical information is captured accurately every time.
Easy Customization
Adapt templates to your specific business needs with customizable fields, branding options, and workflow modifications.
Complete Checklist
- Inspect lightning rod condition
- Verify proper spacing (20 feet max)
- Check mounting security
- Verify minimum rod height
- Inspect for corrosion or damage
- Check roof penetration seals
- Verify proper rod materials
- Inspect terminal connections
- Check for proper grounding
- Verify zone of protection
- Inspect conductor routing
- Verify proper conductor size
- Check conductor connections
- Inspect for physical damage
- Verify proper spacing
- Check conductor supports
- Inspect at roof-to-wall transitions
- Verify minimum number of paths
- Check for proper bends
- Inspect conductor splices
- Test ground resistance (25 ohms max)
- Inspect ground rods or plates
- Verify proper ground depth
- Check ground rod connections
- Test continuity to ground
- Inspect ground ring if present
- Verify proper conductor size
- Check grounding electrode spacing
- Inspect bonding to building steel
- Test earth resistance
- Verify bonding of metal bodies
- Check HVAC equipment bonding
- Inspect metal roof bonding
- Verify piping system bonds
- Check structural steel bonding
- Inspect metal ductwork bonds
- Verify antenna bonding
- Check metal fencing bonds
- Inspect bonding jumpers
- Verify proper bonding conductors
- Inspect SPD condition
- Test SPD operation indicators
- Verify proper SPD installation
- Check SPD grounding connections
- Test SPD protection level
- Verify proper SPD sizing
- Inspect service entrance SPD
- Check panel-level SPDs
- Inspect point-of-use SPDs
- Document SPD test results
- Review original installation plans
- Verify NFPA 780 compliance
- Document any modifications
- Check local code requirements
- Photograph system components
- Update as-built drawings
- Document test results
- Note deficiencies found
- Recommend repairs or upgrades
- Issue inspection certificate