Guide for solar panel cleaning companies · checked 19 November 2026
Software for solar panel cleaning companies: module rules, roof safety, water logs and proof of gain
A solar cleaner sells a few percent of someone else's energy back to them, and can lose the customer a 25-year module warranty with the wrong brush or water that is too cold. This guide covers how a cleaning visit really runs, what each module maker allows, the roof, electrical and wash-water rules, what public cleaning contracts ask for, honest numbers on when cleaning pays, and the software cleaners use, with a source on every figure.
See your own jobs set up this way
A 30-minute call. We show you solar panel cleaning companies workflows running in Fieldproxy, built around how you work.
Short answer
Most solar panel cleaning companies run on a general home-service or exterior-cleaning app: Housecall Pro, ServiceM8, Markate or QuoteIQ for scheduling and invoicing, often with ResponsiBid for quoting. Crews that clean utility plants usually work inside the plant operator's maintenance system instead. What those apps do not hold is the part that is specific to this trade: the module maker's water, pressure and temperature limits per site, the pre-clean crack check, the water purity reading, the roof access plan, and before and after production data. Fieldproxy is one option. Best for processes that don't fit a template, set up for you: each array is a record with its module model and that maker's cleaning limits, the phone form will not let a clean start outside them, and the customer gets a condition report with photos, defects found and the output change.
0.051% a day
Average soiling loss across 186 California rooftop sites in 2010; only 26% of sites lost more than 0.1% a day
10°C
Largest gap LONGi allows between wash water and module temperature. First Solar allows 20°C, Trina minus 5 to plus 10°C
source: LONGi, PV Module Operation and Maintenance Manual V2.0 (2024, PDF)
4 ft
Height at which OSHA general industry rules require fall protection for maintenance work on a roof, skylights included
source: 29 CFR 1910.28, duty to have fall protection and falling object protection
5,676 panels
City of Livermore arrays cleaned once a year; the 2026 award for maintenance, cleaning and reporting starts at $56,400 a year
How a job runs
One solar panel cleaning job, from first call to paid
The order the work really happens in, and what has to be written down at each step so nothing is argued about later.
- 1
Qualify the site and decide whether cleaning will pay
Ask what is on the roof or in the field: panel count, module make and model, tilt, mounting (pitched roof, flat roof, carport, ground mount, tracker), monitoring portal and the last clean date. Then ask what is landing on it: farm dust, a quarry, pollen, birds, diesel soot, sea salt. NREL lists exactly these as the reasons a site needs a cleaning regimen; without one of them, rain may do the job and an honest cleaner says so.
- 2
Count panels and price
Homes are priced per panel or per visit with a minimum. Commercial roofs are priced per panel or per kW with a mobilization charge, and NREL describes large-site pricing as a fixed mobilization fee plus a rate per area. Count from aerial imagery, then confirm on site. Note water supply (tap on site or hauled), access (ladder, lift, internal stair, roof hatch), and whether the work has to be done at night for a retailer.
- 3
Look up the module maker's cleaning rules
Before the first visit, pull the installation manual for the module on site and write down its limits: water pressure, water chemistry, the allowed gap between water and module temperature, brush type, detergents, time of day. They are not the same. LONGi caps pressure at 0.7 MPa, Trina and Canadian Solar recommend no more than 4 MPa, and REC bans pressure washers outright. First Solar forbids wet scrubbing on its anti-reflective coated modules.
- 4
Plan access, fall protection and the electrical boundary
For each roof decide how the crew gets up, where the edge and skylights are, and what protects them: guardrail, travel restraint, personal fall arrest, or cleaning from the ground with a water-fed pole. Mark where the inverter and disconnects are. Rapid shutdown lowers voltage on conductors leaving the array; the modules themselves stay live while the sun is on them.
- 5
Schedule around sun, heat and rain
Makers ask for cleaning in the early morning, at dusk, at night or on an overcast day. LONGi recommends irradiance at or below 200 W/m2. Plan routes so the first array is wet at first light, keep heat rules in mind for afternoon work, and check the forecast: a cleaning the day before real rain is money the customer did not need to spend.
- 6
Inspect before any water touches the array
Walk the array and photograph it dirty. Look for cracked glass, burn marks, exposed or chewed cable, loose connectors, bird nesting under the modules and standing water. Makers are clear that a module with broken glass or exposed wiring must not be wet cleaned because it is a shock hazard. Tag those modules, skip them and report them.
- 7
Clean to the maker's limits
Test the water with a TDS meter and record it. Measure module surface and water temperature. Rinse loose dust first so the brush is not dragging grit across the glass, then brush with a soft, non-conductive brush on a water-fed pole or a brush machine, and rinse. Never stand on a module. Spot treat bird droppings and lichen as the manual allows.
- 8
Contain the wash water
Plain rinse water that soaks into landscaping or gravel is generally fine. Water carrying detergent, biocide or heavy grime that runs to a storm drain is a discharge many cities prohibit. On large sites record litres or gallons used, because county permits and O&M contracts often carry a water budget.
- 9
Document the result
Photograph the array clean from the same positions. Record production or inverter power before and after under similar irradiance, or the soiling station reading on plants that have one. List every defect found with a photo and a location (row, string, module position). That defect list is often worth more to the owner than the wash.
- 10
Report, invoice and set the next visit
Send the condition report, invoice against the contract (per panel, per kW, per visit or a fixed annual price), and set the next cleaning from the contract cycle or from the soiling rate you just measured. Public contracts commonly ask for one or two cleans a year in a named window, with a written report after each.
What to record
The fields every solar panel cleaning job should capture
Per site and array
- Owner, site contact, address, gate or roof access instructions, hours the roof may be worked
- Array list: location on the building or field, panel count, kW DC, tilt, mounting type, year installed
- Module make and model per array, glass type and whether it has an anti-reflective coating
- Module maker limits: maximum water pressure, water pH and hardness or TDS range, allowed water to module temperature gap, brush and detergent rules, load limit, time of day
- Inverter make, monitoring portal and login holder, soiling station or reference cell if fitted
- Water source on site (tap location, pressure, measured TDS) or hauled water requirement
- Soiling sources nearby: fields, unpaved roads, quarry, flight path, birds, trees, coast
Access and safety plan
- Roof height, slope (low slope means 4 in 12 or less under OSHA), edge distance of each array
- Skylights, hatches and fragile surfaces, with photos and how each is protected
- Fall protection method per array: guardrail, travel restraint, personal fall arrest and anchor used, or ground-based pole
- Ladder set-up point, lift type and size if needed, fire access pathways that can be walked
- Location of DC disconnects, rapid shutdown switch and inverter, and who is called before isolation
- Overhead power lines within reach of a pole
Each cleaning visit
- Date, start and finish time, crew, weather, ambient temperature and heat index
- Pre-clean inspection: modules skipped as cracked or with exposed cable, tagged and photographed
- Water TDS in ppm at the brush, water temperature, module surface temperature, the difference
- Method used: water-fed pole, rotating brush, tractor brush, robot, dry clean; brush type; any detergent with product name and dilution
- Panels cleaned and panels skipped with reason, water used, where wash water went
- Before and after photos from fixed positions; before and after inverter power or daily production with irradiance noted
Findings to report
- Cracked or shattered glass, snail trails, burn marks or browning, delamination
- Hot spot suspected (stubborn droppings, shading object, or thermal image if taken)
- Loose, hanging or chewed cable, open connectors, damaged conduit
- Bird nesting or rodent activity under the array, missing critter guard
- Lichen, moss or mould on glass or frames; vegetation shading the array
- Loose clamps or racking, displaced ballast blocks, roof membrane damage near mounts
Rules and standards
The rules that shape the work, with their sources
| Rule | What it means on the job |
|---|---|
| Module maker limits: LONGi | Water to module temperature difference no more than 10°C and no cleaning below 5°C ambient. Pressure on the module surface no more than 0.7 MPa. Non-municipal water must be pH 6 to 8, TDS 1,000 mg/L or less and hardness up to 450 mg/L. Soft sponges, cloths or soft brushes with nylon bristles 0.06 to 0.1 mm thick. Clean in the early morning, at dusk, at night or on a rainy day, with irradiance of 200 W/m2 or less recommended. Do not clean modules with broken glass or exposed cables, and do not stand on modules. source: LONGi, PV Module Operation and Maintenance Manual V2.0 (2024, PDF) |
| Module maker limits: First Solar thin film | No more than 35 bar (500 psi) at the nozzle; water no more than 20°C warmer or colder than the module; total dissolved solids under 1,500 mg/L, with reverse osmosis water giving the best result. Hard water must be squeegeed off. On anti-reflective coated modules, wet contact cleaning (water plus scrubbing) is prohibited and dry cleaning with soft cloths is allowed up to six times a year. It recommends no more than 90 lb on a module, evenly spread. Wet spray without contact is still allowed on coated modules. Motorized tools need First Solar's review, and damage from cleaning is not covered by warranty. source: First Solar, FS-Series PV Module Cleaning Guidelines PD-5-804 Rev 3.4 |
| Module maker limits: Trina, Canadian Solar, Jinko | Trina: water pH 6 to 8, hardness 600 mg/L or less, pressure 4 MPa (40 bar) recommended maximum, water within minus 5 to plus 10°C of the module, no cleaning in wind above Beaufort 4. Canadian Solar: 4 MPa recommended maximum, rotating brushes need its approval first, never rub dry dirt. Jinko: neutral water pH 6.5 to 8, hose or backpack pressure below 675 kPa, never clean a module with broken glass. All three forbid stepping on modules. source: Trina Solar, Vertex Series User Manual UM-M-0002 Ver. PP7 (Aug 2026, PDF) |
| Module maker limits: REC and Qcells | REC: de-ionized water is ideal, a garden hose at domestic pressure is fine, and pressure washers, steam cleaners and high-pressure hoses are not permitted and invalidate the warranty. Clean in the early morning before panels heat up. Qcells gives no pressure number: clean only cooled modules, do not scratch off dirt, and isopropyl alcohol may be used selectively on stubborn stains. Qcells states that cleaning damage is not covered by warranty. source: REC, Quick guide to cleaning (Nov 2020, distributor copy, PDF) |
| 29 CFR 1910.28, fall protection for maintenance | OSHA's solar guidance applies the 6 ft construction trigger to installing panels and the general industry rule, protection at 4 ft, to maintenance, which is where cleaning sits. Skylights 4 ft or more above a lower level are holes and need a cover, guardrail, travel restraint or personal fall arrest. On a low-slope roof: under 6 ft from the edge needs a guardrail, net, travel restraint or fall arrest; 6 ft to under 15 ft allows a designated area only for infrequent and temporary work; at 15 ft or more, infrequent and temporary work needs no fall protection, and a work rule must stop workers going within 15 ft of the edge without it. source: 29 CFR 1910.28, duty to have fall protection and falling object protection |
| 29 CFR 1910.23 and 1910.140, ladders and harnesses | Portable ladder side rails must extend at least 3 ft above the upper landing. Personal fall arrest anchorages must support 5,000 lb per employee, free fall is limited to 6 ft, body belts are prohibited for fall arrest, and the system is inspected before initial use each workshift. source: 29 CFR 1910.140, personal fall protection systems |
| Cal/OSHA Title 8, section 3212 | In California, any employee approaching within 6 ft of a skylight must be protected by a screen, guardrail, cover, net or personal fall protection. Guardrails are required where there is a routine need, more than four times a year, to come within 6 ft of the roof edge. source: California Code of Regulations, Title 8, section 3212 (roof openings and skylights) |
| Energized array | A PV module produces DC whenever light reaches it; LONGi notes strings run from hundreds of volts up to 1,500 V. Rapid shutdown under NEC 690.12, as summarised in an installer guide, drops conductors outside the array boundary to 30 V or less within 30 seconds and limits those inside to 80 V unless a listed hazard control system is used. It does not make the modules themselves dead in daylight. source: GreenLancer, NEC 690.12 solar rapid shutdown requirements, installer guide (2026) |
| IWCA Solar Safety Guidelines | The window cleaning trade body says cleaning panels without accessing the roof is the safest method. It asks crews to inspect for breaks, cracks and water intrusion and mark those panels as not to be cleaned or touched, and to use equipment and PPE rated to at least 1,500 V DC. Its Certified Solar Panel Cleaning Operator route needs a course and exam, at least 75 logged hours and 50 solar sites, and re-certification every 2 years. source: International Window Cleaning Association, Solar Safety Guidelines (PDF, Dec 2023) |
| NREL and DOE cleaning scope language | NREL's O&M guide says to follow the module maker and not to use high-pressure water, brushes, solvents, abrasives or harsh detergents. The DOE's federal O&M RFP template bans high-pressure water, hard-bristled brushes, solvents and abrasives, requires biodegradable cleaners, and offers two schedules: fixed calendar months, or an evidence-based cycle triggered when a measured soiling ratio falls to a set threshold. source: US Department of Energy, O&M RFP template for PV systems (June 2021, .docx) |
| Wash water to storm drains | San Diego's municipal code makes it illegal to discharge polluted wash water from pressure washing or hosing outdoor surfaces to the storm drain system, with penalties up to $10,000 per day per incident, and it applies to contractors. Wash water may go to landscaping if it soaks in. Portland bans pressure washing water from the stormwater system and requires a Mobile Washer Discharge Authorization to send it to sewer. Neither names solar panels; both cover exterior surface washing. source: City of San Diego Think Blue, Pressure Washing fact sheet (PDF) |
| Fire access pathways on the roof | The 2024 IRC, as excerpted by Larimer County, Colorado, requires at least two 36 inch wide pathways from the lowest roof edge to the ridge on separate roof planes, and a ridge setback of 18 inches where the array covers 33% or less of the roof plan area and 36 inches above that. These clear strips are where a cleaner can stand on a pitched residential roof. source: Larimer County, CO, Residential Solar Array Roof Layout, 2024 IRC R329.6 (Jan 2026, PDF) |
| Heat (California Title 8, section 3395) | Shade must be present when the temperature exceeds 80°F and drinking water supplied at one quart per employee per hour. A dark module on a roof in afternoon sun is also the wrong time to clean under every maker's manual, so the heat rule and the manual point to the same early start. source: California Code of Regulations, Title 8, section 3395 (heat illness prevention in outdoor places of employment) |
| Drones | A cleaning drone flown commercially in the US falls under FAA Part 107, which covers unmanned aircraft weighing less than 55 lb on takeoff including everything on board or attached. A drone vendor's own guidance is that the pilot needs a Remote Pilot Certificate and that the payload, hose and any water or chemical in the system count toward the 55 lb. source: 14 CFR 107.3, definitions (small unmanned aircraft) |
Rules vary by state, council and contract. Checked 19 November 2026; confirm against the source for your area before relying on it.
Numbers
Solar panel cleaning numbers, with where each one comes from
Soiling rates are from published studies. Contract figures are from named public documents. Equipment rates are vendor claims and prices from forum posts are one contractor's word. Per-panel sums marked as arithmetic are ours, worked from the document's own totals.
| Measure | Figure | Basis |
|---|---|---|
| Soiling rate, California rooftops | 0.051% a day average; 26% of sites over 0.1% a day | Mejia and Kleissl, 186 sites, 2010 data |
| Loss after a rainless summer | 7.4% after 145 days without rain or washing | Same study, UC San Diego release |
| Value of one mid-summer wash | About $20 of electricity on a typical 5 kW home system | UC San Diego release, 2013 |
| Soiling rate, 11 US sites | 0.02 to 0.05% a day, about 0.04% average | Sandia PVPMC poster, 2025 |
| Soiling rate by cause | 0.36% a day heavy agriculture; up to 0.5% a day large bird populations; about 1.5% a day dust storms in India | NREL O&M guide |
| Rain needed to clean | About 1 mm in the desert Southwest, 5 to 13 mm elsewhere; resets often partial | Sandia PVPMC poster, 2025 |
| Southeast US pollen and mould | Some systems soiled up to 10% and did not recover with rain; cleaning gained 5 to 12% | NREL poster, 2023 |
| Mesa, Arizona simulation | 1.91% annual loss uncleaned; 1.52% with one clean, 1.32% with two, 1.20% with three | Naeem 2014, as reported by NREL |
| Cleaning cost per area | $0.25 per m2 large systems to $1 per m2 single homes; about 1 litre of water per m2 | Naeem 2014, as reported by NREL |
| Cleaning in an O&M budget | $0.80 to $1.30 per kW a year | EPRI 2015, as reported by NREL |
| UK home price | £4 to £15 a panel; most pay £100 to £150; 30 to 45 minutes for most homes | MyJobQuote, Oct 2026 |
| US home price | Around $150 to $350, no system size stated | EnergySage, Aug 2025 |
| US contractor prices | $7 a panel residential; a 4,000 panel commercial job estimated at about 44 hours | Forum posts, 2022 |
| City contract, 5,676 panels | $56,400 in year 1 rising to $63,208 in year 5; about $9.94 a panel a year for maintenance, cleaning and reporting together | City of Livermore award, 2026; per-panel figure is arithmetic |
| State contract | 6,444 panels cleaned and inspected twice a year, C-46 solar licence required | California Military Department, 2025 |
| Indian utility O&M | At least 2 cleaning cycles a month; Rs.1,000 a day if the schedule slips more than 48 hours | SECI 300 MW Ramagiri agreement |
| Water per module, permit filings | 0.5 gallon a module a wash, two washes a year (20 MW); 2 to 3 acre-feet a year for quarterly washing (96 MW) | Cochise County, AZ and Santa Fe County, NM |
| Brush wear over 25 years | Monthly cleaning is about 300 brush cycles, weekly about 1,300, daily about 9,000; one polymer coating lasted 50 to 200 cycles with dust present | NREL abrasion study, 2021 |
| Pure water target | TDS 10 ppm or less for glass; under 40 ppm for opaque surfaces like solar panels | Equipment supplier guidance |
| DI filter yield | One 6 litre resin pack: up to 710 litres, about 100 m2 an hour | Vendor claim, Unger |
| Tractor brush | Up to 10,000 m2 an hour | Vendor claim, SunBrush mobil |
| Bridge robot | Up to 20 MW a day with one operator; 0.5 litre per m2 wet | Vendor claim, SolarCleano B1, trade press |
| Cleaning drone kit | $45,750 one-time | Lucid Bots price page |
source: Mejia and Kleissl, Soiling Losses for Solar Photovoltaic Systems in California, Solar Energy 2013 (manuscript, PDF)source: UC San Diego Today, Cleaning Solar Panels Often Not Worth the Cost (1 Aug 2013)source: Croft and Miller, Soiling inputs for the Kimber model from soiling measurements (PVPMC 2025 poster, Sandia, PDF)source: NREL, Best Practices for Operation and Maintenance of PV and Energy Storage Systems, 3rd ed. (NREL/TP-7A40-73822, Dec 2018, PDF)source: Muller et al., Pollen and Bio-Soiling in the Southeast U.S. (NREL/PO-5K00-85783, Mar 2023, PDF)source: MyJobQuote, Solar panel cleaning cost (UK, updated 12 Oct 2026)source: EnergySage, solar panel cleaning (updated 8 Aug 2025)source: Window Cleaning Resource community, Solar panel commercial (27 Jul 2022)source: City of Livermore, CA, City Council staff report item 6.2, solar maintenance and cleaning agreements (9 Feb 2026, PDF)source: California Military Department, Solar Panel Cleaning and Inspection solicitation (HigherGov listing, 29 Jan 2025)source: Solar Energy Corporation of India, 300 MW Ramagiri tender, Annexure H O&M agreement (PDF)source: Cochise County, AZ, Docket SU 22-12 memorandum, Silicon Ranch 20 MW solar (25 May 2022, PDF)source: Santa Fe County, NM, Case 24-5200 staff final report, Rancho Viejo Solar (PDF)source: Newkirk, Miller et al., Artificial linear brush abrasion of coatings for PV module first-surfaces (2021, DOE manuscript)source: abc Window Cleaning Supply, when to change the filters on a water-fed cartsource: Unger, HydroPower Ultra Filter S product page (UK)source: SunBrush mobil, product pagessource: TaiyangNews, HAALA Energy introduces robotic cleaning to utility PV (SolarCleano B1, 26 Aug 2026)source: Lucid Bots, Sherpa drone pricing
Where it breaks
Where spreadsheets and generic software fall over
One cleaning method for every roof. The crew uses the same pressure and the same brush on a Jinko array (675 kPa limit), a REC array (no pressure washer at all) and a First Solar coated array (no wet scrubbing), because the job card only says 'clean 212 panels'.
Store the module model on the array and the maker's limits beside it, and show those limits at the top of the job on the phone. Block the job from starting if the array has no module model recorded.
No record of water quality or temperature. A year later the owner finds scale or a cracked module and the maker asks how it was cleaned. The cleaner has an invoice and nothing else.
Make TDS, water temperature and module temperature required readings on every visit, with the time, and keep them on the array's history for the life of the contract.
A generic field service app has one job address. A school district has 14 campuses, each with roof arrays and carports of different module makes, counts and access rules, and the app flattens that to 14 lines.
Model client, site and array as three levels, with panel count, module, access plan and price per array, so one contract cycle generates the right jobs with the right checklists.
Roof safety lives in the foreman's head. A new technician is sent to a warehouse roof with unguarded skylights 5 ft from the array and no one told him, or told him which anchor to use.
Hold the access and fall protection plan on the site with photos of edges, skylights and anchors, and require the lead to confirm it on arrival before the checklist opens.
The customer asks 'did it make any difference?' and the answer is a pair of photos. Photos show clean glass, not kilowatt hours, and a wash the day before rain looks like a waste.
Capture inverter power or daily production before and after with the weather noted, state the result plainly even when it is small, and use the measured soiling rate to set the next visit instead of a fixed calendar.
Defects seen on the roof never reach the owner. The technician notices a cracked module and a chewed cable, skips the module, mentions it to nobody, and the owner's O&M provider finds it at the next annual inspection.
Log each defect as its own record with a photo and position, include all of them in the visit report, and offer the repair or a referral as a follow-up job.
Checklist
The solar panel cleaning operations checklist
Print it, or hand it to whoever runs the office side.
- Every array has its module make and model recorded before the first clean
- Module maker limits for pressure, water chemistry, temperature gap and brush type stored per array
- Access and fall protection plan per roof, with skylights and edges photographed
- Fall protection training and equipment inspection dates on file for every roof technician
- Start times set for early morning, dusk or night; no cleaning of hot modules
- Forecast checked: no paid clean the day before meaningful rain
- Pre-clean walk done; cracked modules and exposed cables tagged, skipped and photographed
- TDS, water temperature and module temperature recorded at every visit
- Loose dust rinsed before brushing; soft non-conductive brush only; nobody stands on a module
- Detergent or biocide used only if the maker allows it, with product and dilution recorded
- Wash water kept out of storm drains; water volume logged on large sites
- Before and after photos from the same positions
- Before and after production or inverter power recorded with weather
- Defect list with positions sent to the owner within a day
- Next clean set from the contract window or the measured soiling rate
Software options
What software solar panel cleaning companies actually use
Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.
QuoteIQ
Small and growing exterior cleaning and solar cleaning crews
A field service CRM that markets directly to solar panel cleaners, with quoting, scheduling and invoicing and satellite roof measurement on its higher plans. Published tiers run from $29.99 to $699 a month. Its own pages differ on whether the measurement tool returns a panel count, so confirm how you would count panels.
ResponsiBid
Window and exterior cleaners adding solar as a service line
A quoting and sales follow-up tool for exterior cleaning that sits in front of a scheduling app and links to Jobber and Housecall Pro. Startup plan free, Scaling $179 a month, Pro $229 a month. It prices jobs; it does not run the visit.
Housecall Pro
Residential cleaners with a few crews
General home-service scheduling, invoicing and payments. Published monthly prices are $79 for one user, $189 for five and $329 for eight. Good at booking and reminders; it has no concept of an array, a module model or a production reading.
ServiceM8
Owner-operators and small teams who want to pay by job volume
Job management priced by jobs per month rather than by user: free for 30 jobs, then $29, $79, $149 and $349 a month for up to 50, 150, 500 and 1,500 or more jobs. Forms and photos per job are flexible; multi-level client, site and array structures are not what it was built for.
Markate
Solo operators
CRM and operations for small exterior cleaning businesses at $49.95 a month for an owner-operator, with team members added at $5 each. A low-cost way to quote, schedule and invoice residential cleans.
60Hertz
Crews cleaning for plant owners and O&M providers
A maintenance system built for solar, storage and wind operations with a field inspection app. On utility sites the cleaning contractor is often given work orders in the operator's system like this one rather than choosing its own. Pricing is not published.
Published prices, compared:source: QuoteIQ, solar panel cleaning field service software (pricing tiers)source: ResponsiBid, pricingsource: Housecall Pro, pricingsource: ServiceM8, pricing (US)source: Markate, pricingsource: 60Hertz Energy, maintenance software for solar, storage and wind
Questions to ask any vendor
- Can I hold client, site and array as separate levels, with a different module model, panel count and price on each array?
- Where do the module maker's pressure, water and temperature limits live, and does the technician see them on the job?
- Can I make TDS, water temperature and module temperature required fields, and stop a job if they are out of range?
- Can each roof carry its own access and fall protection plan with photos that the crew must confirm on arrival?
- Can the visit report include before and after production figures and a defect list with positions, on my own template?
- Can recurring cleans be generated from a contract window, such as March to May, or from a soiling threshold, not only a fixed interval?
Bring one real solar panel cleaning job. We show it running in Fieldproxy.
Get DemoHow Fieldproxy is set up for this
Solar panel cleaning on Fieldproxy: built around how you already work
A Fieldproxy setup for a solar cleaning company is built around the array, not the address. Each array carries its module model, that maker's cleaning limits, its access plan and its price; each visit carries the water readings, the skipped modules, the photos and the production change; and each contract carries its cleaning windows and report format. It is built to match how your crews already quote, wash and report, and you are live within a day: your first crew runs real jobs in Fieldproxy the day after the call.
Module 1
Client, site and array register
A cleaner's unit of work is the array, and one client can have hundreds of them across roofs, carports and fields with different modules on each.
- Three linked records: Client (owner or O&M provider), Site (address, contact, access hours, gate and roof access notes), Array (location on site, panel count, kW DC, tilt, mounting type, year installed)
- Array fields: module make and model, anti-reflective coating (yes, no, unknown), inverter make, monitoring portal, soiling station fitted (yes or no)
- Soiling sources as tick boxes on the site: agriculture, unpaved road, quarry or construction, pollen, birds, diesel or flight path, coast
- Water on site: tap location, measured TDS at the tap, hauled water needed (yes or no)
- Statuses for an array: Surveyed, Active, On hold, Decommissioned
- A block: an array cannot be put on a cleaning job until its module make and model are filled
Module 2
Module rule sheets
The limits come from the module maker, they differ by a factor of nearly six on pressure alone, and breaking them can cost the owner the warranty.
- One rule sheet per module family: maximum pressure, pH range, hardness or TDS limit, allowed water to module temperature gap, minimum ambient temperature, brush type, detergents allowed and banned, load limit, time of day, manual version and link
- Examples to seed it: LONGi 0.7 MPa and 10°C; First Solar 35 bar, 20°C, no wet scrubbing on coated modules; Trina 4 MPa and minus 5 to plus 10°C; Jinko below 675 kPa; REC no pressure washer
- The array's rule sheet is shown at the top of every job on the phone
- A flag on rule sheets that need the maker's written approval for rotating brushes or robots (Canadian Solar, First Solar), with the approval letter attached to the client
- Review date on each sheet so manuals are re-checked, e.g. yearly
Module 3
Survey, panel count and quote
Price depends on the count, the access and the water, and a wrong count on a 4,000 panel roof is the whole margin.
- Enquiry form: panel count if known, building type, last clean, what is soiling it, monitoring access
- Survey job with photos: counted panels per array, roof height and slope, access route, water point, obstructions
- Quote lines per array: panels x rate, or kW x rate, plus mobilization, lift hire, hauled water, night work uplift, with a minimum charge for homes
- Options on the quote: one-off clean, twice a year, quarterly, with bird droppings spot visits priced separately
- A plain statement on the quote of expected benefit, e.g. the site's soiling sources and what a clean is likely to recover, so nobody is promised 20%
- Statuses: Enquiry, Survey booked, Quoted, Accepted, Declined, with the reason for a decline recorded
Module 4
Contracts and cleaning cycles
Public and commercial work is won as a multi-year contract with a stated number of cleans, a window and a report, and missing the window is a breach.
- Contract fields: term and renewal options, cleans per year, cleaning window (e.g. March to May), response time for call-outs, report required after each visit, insurance and licence requirements such as California C-46, price per year with escalation
- Cycle type per contract: fixed months, or evidence-based with a soiling ratio or production threshold as the trigger
- Jobs generated per array for each cycle, grouped into visits per site
- Penalty terms held on the contract where they exist, e.g. a daily amount if the schedule slips by more than 48 hours
- Not-to-exceed budget tracking for contracts that bundle on-call repairs with scheduled cleaning
- Renewal task raised e.g. 120 days before the term ends
Module 5
Scheduling around sun, heat, rain and equipment
The work has to happen when the glass is cool, and the trailer, the lift and the RO unit have to be in the same place as the crew.
- Job time windows: first light, dusk or night, set per site, with night-only flags for retail roofs
- Equipment as schedulable resources: RO/DI trailer, water tank, lift, brush machine, robot, drone with its certified pilot
- Crew skills and tickets: fall protection training date, lift operator card, IWCA solar certification, drone Remote Pilot Certificate
- Rain rule you set, e.g. a clean is held for review if 5 mm or more is forecast in the next 48 hours
- Heat rule you set, e.g. no roof work booked to start after 10 a.m. when the forecast heat index is above 90°F
- Route grouping so several homes or several campuses in one area are cleaned in one early run
Module 6
Roof access and safety plan
Cleaning is maintenance under OSHA, the trigger is 4 ft, and the hazards on a commercial roof are the edge and the skylights, not the panels.
- Plan per site: roof height and slope, distance of each array from the edge (under 6 ft, 6 to 15 ft, 15 ft or more), skylights and hatches with photos
- Protection method per array: guardrail present, travel restraint, personal fall arrest with the anchor identified, or ground-based pole only
- Ladder set-up point with the 3 ft extension noted, or lift position and ground conditions
- Electrical notes: disconnect and rapid shutdown locations, overhead lines within pole reach, the site contact to call before isolation
- Arrival check on the phone: lead confirms the plan, harness and lanyard inspected this shift, skylights located; the cleaning checklist stays locked until it is done
- Plan review date and a required re-survey after any roof works
Module 7
The cleaning visit on the phone
The evidence that the job was done to the maker's rules has to be captured while the brush is wet, by someone wearing gloves.
- Step 1, pre-clean walk: dirty photos from fixed positions, count of modules skipped, each skipped module tagged with reason (cracked glass, exposed cable, burn mark) and photo
- Step 2, readings: TDS in ppm at the brush, water temperature, module surface temperature; the form shows the gap against the array's limit and warns if it is over
- Step 3, method: pole, rotating brush, tractor brush, robot or dry clean; brush type; detergent or biocide with product and dilution, only selectable if the rule sheet allows it
- Step 4, clean and rinse, panels cleaned, water used, where the wash water went (soaked into landscape, captured, to sewer with authorization)
- Step 5, clean photos from the same positions and the after reading
- Works offline on roofs and remote plants and syncs later; voice notes accepted for findings
Module 8
Defects and follow-up work
The cleaner is the only person who looks at every module up close each year, and what they see is worth reporting and often worth quoting.
- Defect record per finding: type (cracked glass, hot spot suspected, cable damage, open connector, nesting, lichen, loose clamp, roof damage), array, row and module position, photo, severity
- Statuses: Reported, Owner notified, Quoted, Referred to O&M provider, Fixed, No action
- Follow-up job types: bird droppings spot clean, critter guard install, lichen treatment, vegetation trim, re-clean
- Defects carried forward so the next visit's checklist asks whether each open one is still present
- Skipped modules listed by position so the owner's electrician can find them
Module 9
Proof of gain and the condition report
Published studies say many cleans recover little, so the cleaner who measures and reports honestly keeps the contract.
- Production fields per visit: inverter power or daily kWh before and after, irradiance or weather note, source (portal reading, screenshot, soiling station)
- Monitoring data brought in from the owner's portal by import or the open API where they allow it
- Measured soiling rate per array from the gap between cleans, used to suggest the next clean date
- Condition report PDF on your template: site and arrays cleaned, readings, method, water used, photos, production change, defect list with positions, modules skipped
- Client portal: visit history, reports, open defects, next scheduled window, request form for a call-out
- Report due rule from the contract, e.g. within 5 working days of the visit
Module 10
Invoicing and owner reporting
Margin in this trade is panels per hour and litres per panel, and neither is visible without the visit data.
- Invoice per visit, per cycle or per month from the contract price, with extras (lift, hauled water, call-outs) as separate lines; synced to QuickBooks or Xero
- Productivity per job: panels per crew hour, water per panel, travel time, by method and by site type
- Contract compliance: cleans done inside the window, reports sent on time, call-outs inside response time
- Equipment log: RO membrane and DI resin changes against litres produced, brush head replacements, harness inspection dates
- Dashboard for the owner: quoted against won, revenue per crew day, repeat rate, defects reported and converted to work
The AI agents, set up for solar panel cleaning companies
| Agent | When | What it does | What you get |
|---|---|---|---|
| Document intelligence agent | A module installation manual, an RFP or a signed cleaning contract arrives as a PDF | Reads the cleaning section of the manual for pressure, water chemistry, temperature gap, brush and detergent rules, or reads the contract for cleans per year, window, report and insurance requirements. | A draft module rule sheet or contract record with those fields filled, the page each came from, and anything missing flagged for a person to check. |
| Vision agent | A technician uploads pre-clean photos, or photographs a module nameplate on the back of a panel | Reads make, model and rating from the label, and checks array photos for cracked glass, burn marks, heavy droppings and nesting. | Module fields filled on the array, and draft defect records with the photo attached for the technician to confirm or dismiss. |
| Watcher agent | A reading is saved on a visit, a contract window is two weeks from closing, or imported production data for an array drops against its clean baseline | Compares TDS, pressure and the water to module temperature gap with that array's rule sheet, checks which contracted arrays have no completed clean in the window, and compares the soiling drop with the threshold set for evidence-based contracts. | A stop warning on the job and a note to the supervisor, a list of arrays at risk of missing their window, or a proposed cleaning job for the array that crossed its threshold. |
| Dispatch agent | A cycle's jobs are released for scheduling, or a call-out is logged | Matches each site to a crew with the right tickets (fall protection, lift, drone pilot), the right equipment free (RO trailer, lift, brush machine) and a start time inside the site's cool-glass window. | Jobs assigned and sequenced into early-morning or night runs by area, with the equipment reserved. |
| Autopilot | A quote has had no reply for e.g. 5 days, a one-off customer's last clean is 10 months old, or a defect has sat at Owner notified for 14 days | Drafts the follow-up using the site's own facts: the panel count and price, the production change measured last time, or the photo and position of the open defect. | A drafted email or text waiting for a person to approve before it sends. |
| Scheduler agent | Every Friday afternoon, and on the first of each month | Gathers next week's sites with forecast rain and heat, crews and equipment booked, and for the month: cleans done inside contract windows, reports outstanding, panels per crew hour and open defects by client. | A weekly plan email to supervisors and a monthly contract summary to the owner, with one page per client that can be forwarded as is. |
Straight answers
Solar panel cleaning: FAQ
What software do solar panel cleaning companies use?
Most use a general home-service or exterior-cleaning app such as Housecall Pro, ServiceM8, Markate or QuoteIQ, often with ResponsiBid for quoting. Crews working on utility plants usually take work orders in the plant operator's maintenance system. None of the general apps hold module maker cleaning limits, water readings or before and after production as standard. Fieldproxy is an option for cleaners who want those built around their own process.
Is cleaning solar panels worth it?
It depends on what is landing on them. A UC San Diego study of 186 California sites found an average loss of 0.051% a day, and estimated that washing a typical 5 kW home system mid-summer gained about $20 of electricity. NREL reports far higher rates near heavy agriculture (0.36% a day) and large bird populations (up to 0.5% a day), and an NREL poster found mould-soiled systems in the US Southeast that gained 5 to 12% from cleaning. A site-specific check beats a rule of thumb.
How often should solar panels be cleaned?
There is no single interval. Public contracts in California commonly ask for one or two cleans a year; the City of Livermore cleans 5,676 panels annually and the California Military Department cleans 6,444 panels twice a year. An Indian utility O&M agreement requires at least two cleaning cycles a month. The US Department of Energy's contract template offers a fixed calendar or a cycle triggered when a measured soiling ratio falls to a threshold.
Can you pressure wash solar panels?
Check the module maker's manual, because they disagree. REC says pressure washers and high-pressure hoses are not permitted and invalidate the warranty. LONGi limits pressure on the module surface to 0.7 MPa and Jinko to below 675 kPa. Trina and Canadian Solar give a recommended maximum of 4 MPa, and First Solar allows up to 35 bar at the nozzle. NREL's guide says not to use high-pressure water at all.
What water should be used to clean solar panels?
Low-mineral water, so it dries without scale. REC calls de-ionized water ideal and First Solar says reverse osmosis water gives the best result, but neither requires it: LONGi accepts water with total dissolved solids up to 1,000 mg/L and First Solar up to 1,500 mg/L if hard water is squeegeed off. A window cleaning supplier's guidance for water-fed poles is a TDS reading under 40 ppm for solar panels and 10 or less for glass.
Why are solar panels cleaned early in the morning or at night?
Cold water on hot glass risks thermal shock, and every maker sets a limit. LONGi allows no more than 10°C between water and module, Trina minus 5 to plus 10°C, and First Solar 20°C. LONGi recommends cleaning when irradiance is 200 W/m2 or less. REC notes panels run around 20°C above ambient, which is why a mid-afternoon wash is the wrong time.
Does rain clean solar panels?
Often, but not always fully. A 2025 analysis of 11 US sites found about 1 mm of rain was enough for a cleaning event in the desert Southwest and 5 to 13 mm elsewhere, and many resets were partial. Canadian Solar says modules tilted at 15 degrees or more generally may not need cleaning. NREL found pollen and mould soiling in the Southeast that regular rain did not remove.
What fall protection do solar panel cleaners need?
In the US, OSHA applies its general industry rules to maintenance of solar arrays, so protection is required at 4 ft, including around skylights. On a low-slope roof, work within 6 ft of the edge needs a guardrail, net, travel restraint or personal fall arrest; from 6 to 15 ft a designated area is allowed only for infrequent and temporary work. The International Window Cleaning Association says cleaning from the ground without roof access is the safest method.
Can cleaning damage solar panels or void the warranty?
Yes. First Solar, Qcells, Trina and Canadian Solar all say damage from improper cleaning is not covered. Standing on a module, scrubbing dry dust, or using an abrasive brush can scratch glass and wear the anti-reflective coating. An NREL study found one polymer coating lasted only 50 to 200 brush cycles when dust was present, against roughly 300 cycles for 25 years of monthly cleaning.
Is it safe to clean a cracked solar panel?
No. LONGi, Jinko, Trina and REC all say not to wet clean a module with broken glass or exposed wiring because of the shock hazard, and First Solar notes the leakage current risk gets worse when the module is wet. Modules are live whenever light reaches them, with strings running up to 1,500 V. The practice is to tag the module, skip it and report it to the owner.
How much does solar panel cleaning cost?
For UK homes, MyJobQuote reports £4 to £15 a panel with most people paying £100 to £150. EnergySage puts US professional cleaning at around $150 to $350. NREL cites $0.25 per m2 for large systems up to $1 per m2 for single homes. As a public contract example, Livermore's 2026 award for annual maintenance, cleaning and reporting on 5,676 panels starts at $56,400 a year.
Do you need a licence or certification to clean solar panels?
There is no national US licence for cleaning alone, but contracts can add one: a California Military Department solicitation required a C-46 Solar Contractor licence or a licensed subcontractor. The International Window Cleaning Association runs a Certified Solar Panel Cleaning Operator route that needs 75 logged hours and 50 sites, and the Power Washers of North America lists solar cleaning and solar safety training.
Related guides
All sources on this page (43)
- source: Mejia and Kleissl, Soiling Losses for Solar Photovoltaic Systems in California, Solar Energy 2013 (manuscript, PDF)
- source: LONGi, PV Module Operation and Maintenance Manual V2.0 (2024, PDF)
- source: 29 CFR 1910.28, duty to have fall protection and falling object protection
- source: City of Livermore, CA, City Council staff report item 6.2, solar maintenance and cleaning agreements (9 Feb 2026, PDF)
- source: First Solar, FS-Series PV Module Cleaning Guidelines PD-5-804 Rev 3.4
- source: Trina Solar, Vertex Series User Manual UM-M-0002 Ver. PP7 (Aug 2026, PDF)
- source: REC, Quick guide to cleaning (Nov 2020, distributor copy, PDF)
- source: 29 CFR 1910.140, personal fall protection systems
- source: California Code of Regulations, Title 8, section 3212 (roof openings and skylights)
- source: GreenLancer, NEC 690.12 solar rapid shutdown requirements, installer guide (2026)
- source: International Window Cleaning Association, Solar Safety Guidelines (PDF, Dec 2023)
- source: US Department of Energy, O&M RFP template for PV systems (June 2021, .docx)
- source: City of San Diego Think Blue, Pressure Washing fact sheet (PDF)
- source: Larimer County, CO, Residential Solar Array Roof Layout, 2024 IRC R329.6 (Jan 2026, PDF)
- source: California Code of Regulations, Title 8, section 3395 (heat illness prevention in outdoor places of employment)
- source: 14 CFR 107.3, definitions (small unmanned aircraft)
- source: UC San Diego Today, Cleaning Solar Panels Often Not Worth the Cost (1 Aug 2013)
- source: Croft and Miller, Soiling inputs for the Kimber model from soiling measurements (PVPMC 2025 poster, Sandia, PDF)
- source: NREL, Best Practices for Operation and Maintenance of PV and Energy Storage Systems, 3rd ed. (NREL/TP-7A40-73822, Dec 2018, PDF)
- source: Muller et al., Pollen and Bio-Soiling in the Southeast U.S. (NREL/PO-5K00-85783, Mar 2023, PDF)
- source: MyJobQuote, Solar panel cleaning cost (UK, updated 12 Oct 2026)
- source: EnergySage, solar panel cleaning (updated 8 Aug 2025)
- source: Window Cleaning Resource community, Solar panel commercial (27 Jul 2022)
- source: California Military Department, Solar Panel Cleaning and Inspection solicitation (HigherGov listing, 29 Jan 2025)
- source: Solar Energy Corporation of India, 300 MW Ramagiri tender, Annexure H O&M agreement (PDF)
- source: Cochise County, AZ, Docket SU 22-12 memorandum, Silicon Ranch 20 MW solar (25 May 2022, PDF)
- source: Santa Fe County, NM, Case 24-5200 staff final report, Rancho Viejo Solar (PDF)
- source: Newkirk, Miller et al., Artificial linear brush abrasion of coatings for PV module first-surfaces (2021, DOE manuscript)
- source: abc Window Cleaning Supply, when to change the filters on a water-fed cart
- source: Unger, HydroPower Ultra Filter S product page (UK)
- source: SunBrush mobil, product pages
- source: TaiyangNews, HAALA Energy introduces robotic cleaning to utility PV (SolarCleano B1, 26 Aug 2026)
- source: Lucid Bots, Sherpa drone pricing
- source: QuoteIQ, solar panel cleaning field service software (pricing tiers)
- source: ResponsiBid, pricing
- source: Housecall Pro, pricing
- source: ServiceM8, pricing (US)
- source: Markate, pricing
- source: 60Hertz Energy, maintenance software for solar, storage and wind
Run solar panel cleaning work the way it actually runs.
A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.
Get a walkthroughOne price per company. Unlimited users.