Cooling tower water treatment, run on the logbook, the lab result and the 24-hour clock

A cooling tower water treatment company sells chemistry, but it gets paid for records: pH, conductivity and halogen three times a week, a dip slide every week, a Legionella culture every 31 days in New York City, and a documented response within 24 hours when a result comes back high. This guide covers ASHRAE 188 water management programs, NYC's 2026 rule change, NY State's action levels, startup and summertime disinfection, who may add biocide, what goes in the service report, and how the work differs in the UK and Canada.

See your own jobs set up this way

A 30-minute call. We show you cooling tower water treatment companies workflows running in Fieldproxy, built around how you work.

Book your demo

A video call with our team

Number of employees

Short answer

Cooling tower water treatment companies usually combine a controller's cloud platform for live readings and chemical feed (for example Advantage Controls' WebAdvantage), a service report tool built for water treaters (Aliquot from AquaPhoenix, or MyTechReports), and a lab portal for Legionella results, with spreadsheets filling the gaps between them. Facility teams sometimes keep the logbook in a CMMS such as Oxmaint. Fieldproxy is one option for the treater's own system: a register of towers and their plans, route visits with readings checked against each tower's limits, Legionella and dip slide results that open the right corrective action with its deadline, and service reports and certifications in the format the building and the health department expect.

31 days

Maximum gap between Legionella samples for operating cooling towers in New York City since 8 May 2026, up from 90 days

source: NYC Health press release, New cooling tower Legionella testing regulations take effect (8 May 2026)

10 CFU/mL

NYC Legionella result that requires documented corrective action; at 1,000 CFU/mL or more the tower is fully remediated within 48 hours and the city is told within 24

source: 24 RCNY Chapter 8, Cooling Towers (Tables 8-1 and 8-2, record retention)

3x a week

NYC minimum for pH, temperature, conductivity and biocide residual readings, with no more than two days in a row between them

source: NYC Health, Cooling Towers: Information for Owners and Operators (frequencies, roles, portal uploads)

Jul 1 to Aug 31

Window for NYC's required summertime hyperhalogenation, followed by a Legionella test 3 to 31 days later

source: NYC Health, Cooling Tower Registration and Maintenance (monthly sampling from 8 May 2026, hyperhalogenation)

How a job runs

One cooling tower water treatment job, from first call to paid

The order the work really happens in, and what has to be written down at each step so nothing is argued about later.

  1. 1

    Survey the system and write the plan

    Walk the system: towers and cells, basins, sumps, chillers, heat exchangers, bypass lines and dead legs, make-up source, controller and feed pumps, sample points. Write or update the water management program that ASHRAE 188 calls for (in New York, the Maintenance Program and Plan, certified each year by a Qualified Person), with control limits, sampling points, responsibilities and corrective actions for each tower.

  2. 2

    Clean, disinfect and start up

    In New York City, a tower shut down or untreated for 5 or more days is cleaned and disinfected within 15 days before it goes under heat load, with pH and halogen checked at two locations. A Qualified Person does a pre-startup inspection, water is circulated with treatment, and a Legionella sample is taken 3 to 14 days after startup. The startup date goes into the city portal within 5 days.

  3. 3

    Feed chemistry and control cycles

    Water is treated daily with oxidizing biocide and scale and corrosion chemistry by automated feed (NYC allows manual feed only if the plan proves it works). The controller bleeds off on a conductivity set point to hold the target cycles of concentration, which EPA defines as blowdown conductivity divided by make-up conductivity.

  4. 4

    Run routine monitoring

    Building staff or the treater's technician log pH, temperature, conductivity and free halogen or ORP from the plan's sample points at least three times a week, do a weekly visual check of the tower, and run a weekly dip slide or lab HPC. Every chemical addition is logged with product, purpose, time and amount, with the safety data sheet on file.

  5. 5

    Sample for Legionella

    Take the culture sample at least an hour after a biocide feed ends, from the points the plan names, and ship it to an accredited lab (ELAP-certified in New York). In NYC, the Qualified Person enters the sample date in the city portal within 5 days. Outside NYC in New York State, routine sampling follows the state rule and plan.

  6. 6

    Act on the result

    In NYC, 10 to under 100 CFU/mL means stronger or different biocide within 24 hours, a treatment review and a retest in 3 to 7 days. 100 to under 1,000 adds a visual inspection for cleaning. 1,000 or more means full remediation within 48 hours (hyperhalogenate, drain, clean, flush) and a report to the city within 24 hours. Each step is dated and recorded until a result comes back under 10.

  7. 7

    Inspect every 90 days

    The Qualified Person does a compliance inspection at least every 90 days while the tower runs, reviewing the logbook, chemical records, dip slides, Legionella results and open corrective actions, and noting deficiencies for the owner.

  8. 8

    Hyperhalogenate in summer and clean twice a year

    In NYC, every operating tower gets a summertime hyperhalogenation between July 1 and August 31 (Table 8-1 defines it as 5 to 10 ppm free halogen for at least 1 hour), a Legionella test 3 to 31 days later, and a declaration in the portal within 30 days. Towers are cleaned at least twice a year, including startup. The person applying biocide holds a 7G cooling tower pesticide applicator certification.

  9. 9

    Certify, invoice and keep the records

    The annual certification goes into the NYC portal (and NY State's) by November 1. Records of every reading, addition, inspection and corrective action are kept at least 3 years. Invoices cover the chemical program, service visits, lab fees, cleanings and disinfections, and emergency remediation.

What to record

The fields every cooling tower water treatment job should capture

Tower and plan

  • Building, owner, registration numbers (NYC portal and NY State registry where applicable)
  • System ID, towers and cells, open or closed circuit, volume, make-up source, chillers and heat exchangers served
  • Sample points named in the plan, dead legs and bypasses, partial operation modes and valve schedule
  • Control limits: pH range, conductivity set point and target cycles, free halogen or ORP target, inhibitor residual
  • Plan version, Qualified Person, certification date, operation period, startup and shutdown dates

Every visit and log entry

  • pH, temperature, conductivity, free halogen or ORP, from which sample point and at what time
  • Make-up and blowdown meter readings, cycles worked out
  • Chemical added: product, manufacturer, purpose, amount, date and time, who added it, applicator certification
  • Dip slide or HPC: start and end of incubation, result in CFU/mL, Table 8-2 level
  • Visual check: drift eliminators, fill, basin debris and biofilm, controller and pump status, photos

Legionella and corrective actions

  • Sample date and time, sample point, minutes since last biocide feed, lab and chain of custody
  • Result in CFU/mL, level under the local table, date received
  • Corrective action: what was done, when, by whom, dose and contact time, retest date and result
  • Notifications: city or health department report time for results at or above 1,000 CFU/mL
  • Cleaning and disinfection records: startup, summertime hyperhalogenation, twice-yearly cleaning, declarations

Rules and standards

The rules that shape the work, with their sources

RuleWhat it means on the job
ASHRAE Standard 188-2021Sets minimum legionellosis risk management requirements for building water systems, written in enforceable language so codes and regulators can adopt it. ASHRAE Guideline 12-2023 supplements it with practice guidance. Most water management programs for cooling towers are written to these two documents. source: ASHRAE, Standard 188-2021 fact sheet (Legionellosis: Risk Management for Building Water Systems)
NYC: 24 RCNY Chapter 8 monitoring frequenciesWeekly visual monitoring, water quality readings three times a week (no more than two days in a row between them), weekly bacteriological indicator, Legionella at startup and every 31 days, compliance inspection by a Qualified Person every 90 days, cleaning at least twice a year. source: NYC Health, Cooling Towers: Information for Owners and Operators (frequencies, roles, portal uploads)
NYC: Table 8-1 Legionella corrective actionsUnder 10 CFU/mL: maintain or adjust. 10 to under 100: disinfect within 24 hours, review, retest in 3 to 7 days. 100 to under 1,000: add a visual inspection for cleaning. 1,000 or more: disinfect within 24 hours, fully remediate within 48 hours, notify the city within 24 hours. Retest until under 10. source: 24 RCNY Chapter 8, Cooling Towers (Tables 8-1 and 8-2, record retention)
NYC: Table 8-2 dip slide and HPC actionsA weekly bacteriological indicator at or above 10,000 CFU/mL means checking disinfectant residual three times a day until target residual holds for 24 hours, and taking a Legionella sample if that is not achieved within three days. source: 24 RCNY Chapter 8, Cooling Towers (Tables 8-1 and 8-2, record retention)
NYC: portal deadlinesStartup and shutdown dates within 5 days, Legionella sample dates within 5 days of collection (by the Qualified Person, from an individual's email, not a company's), results of 1,000 CFU/mL or more within 24 hours, hyperhalogenation declaration within 30 days, annual certification by November 1. source: NYC Health, Cooling Towers: Information for Owners and Operators (frequencies, roles, portal uploads)
NYC: records kept 3 yearsOwners keep records of every maintenance task, inspection, deficiency, corrective action, water treatment, test result, cleaning and disinfection for at least 3 years. Failing to produce a required record on request counts as prima facie evidence it does not exist. source: 24 RCNY Chapter 8, Cooling Towers (Tables 8-1 and 8-2, record retention)
NY State: Subpart 4-1 and Appendix 4-AOutside NYC, results of 20 CFU/mL or more trigger online disinfection and a retest in 3 to 7 days; 1,000 or more triggers online decontamination (at least 5 ppm free halogen for an hour), notifications, and system decontamination if a retest stays at 1,000. Chlorine works at pH 7.0 to 7.6, bromine at 7.0 to 8.7. source: 10 NYCRR Subpart 4-1, Appendix 4-A: Interpretation of Legionella culture results from cooling towers
NY State: inspections, registry and certificationTowers are inspected before seasonal startup and every 90 days in use, the state registry is updated every 90 days while operating, the local health department is told within 24 hours of a result over 1,000 CFU/mL, and certification is due by November 1. source: NY State Department of Health, Protection Against Legionella: Cooling Tower Requirements
Who may add biocide in New YorkAnyone applying biocide or disinfecting a cooling tower in New York needs a commercial pesticide applicator certification in category 7G (cooling towers) from the NYS DEC, and only DEC-registered biocides may be used. source: NYS DEC, Pesticide applicator certification (commercial categories including 7G cooling towers)
CMS S&C 17-30 for healthcare buildingsCMS's 2017 memo, Requirement to Reduce Legionella Risk in Healthcare Facility Water Systems, is what pushed hospitals, critical access hospitals and nursing homes into formal water management programs. CMS now lists the memo as expired, so a hospital contract should follow the facility's current survey guidance and its own program, which usually still cover the cooling towers. source: CMS, Survey and Certification Letter 17-30: Legionella water management for hospitals, CAHs and nursing homes
UK: HSE L8 and HSG274 Part 1HSE expects routine Legionella testing of open systems such as cooling towers at least quarterly, sampled to BS 7592 with the biocide neutralised where possible and tested by a UKAS-accredited lab. source: HSE (UK), Testing and monitoring your water system for legionella
Canada: city and provincial registriesHamilton, Ontario was the first Canadian city to require cooling tower registration after outbreaks in 2006 and 2008, Quebec followed after a 2012 Quebec City outbreak with monthly analysis by an accredited lab, and Vancouver requires an operating permit for every cooling tower and evaporative condenser. source: NCCEH, Cooling tower registries and building water management plans (Hamilton, Quebec, Vancouver)
Quebec: monthly accredited lab analysisQuebec's 2014 cooling tower maintenance rules under the Safety Code made the hardest obligation for owners the monthly analysis of samples by a laboratory accredited by the province's Centre d'expertise en analyse environnementale, alongside the provincial cooling tower registry. source: Lavery, Quebec's new cooling tower maintenance regulation (monthly accredited lab analysis)
Cycles of concentration and blowdownEPA WaterSense defines cycles of concentration as blowdown conductivity divided by make-up conductivity, and water leaves a tower by evaporation, blowdown, drift, and leaks and overflows. A conductivity controller bleeding on a set point is how the target cycles in the plan are held, and make-up and blowdown meters check it. source: US EPA WaterSense at Work, Section 6.3 Cooling Towers (cycles of concentration, blowdown)

Rules vary by state, council and contract. Checked 26 November 2026; confirm against the source for your area before relying on it.

Numbers

NYC cooling tower frequencies and limits, in one table

New York City has the most detailed rules in the US, so many treaters elsewhere use them as the reference schedule. Figures from 24 RCNY Chapter 8 and the NYC Health Department's owner guidance, current from 8 May 2026, with NY State, CDC and UK figures for comparison.

Task or limitNYC requirementFor comparison
Legionella cultureEvery 31 days while operating (since 8 May 2026)NYC was every 90 days; UK HSE at least quarterly
Startup Legionella3 to 14 days after startupTower cleaned and disinfected within 15 days before heat load
Water quality readings3 times a week, max 2 days betweenpH, temperature, conductivity, biocide residual
Dip slide or HPCWeekly; 10,000 CFU/mL or more triggers actionTable 8-2
Visual monitoringWeeklyBy a Responsible Person under the Qualified Person
Compliance inspectionEvery 90 days by a Qualified PersonNY State: before startup and every 90 days
CleaningAt least twice a year, including startupCDC: offline clean and disinfect at least yearly
HyperhalogenationJul 1 to Aug 31; 5 to 10 ppm free halogen, at least 1 hLegionella retest 3 to 31 days later
Legionella action level10 CFU/mLNY State outside NYC: 20 CFU/mL
Report a high result1,000 CFU/mL or more, within 24 hSame threshold and clock in NY State
Full remediationWithin 48 h of a 1,000+ resultCDC emergency disinfection: at least 20 ppm free available oxidant
Records keptAt least 3 yearsAnnual certification by November 1
Registered systemsAbout 5,000 systems at about 4,000 buildingsNYC Health figures

source: 24 RCNY Chapter 8, Cooling Towers (Tables 8-1 and 8-2, record retention)source: NYC Health, Cooling Towers: Information for Owners and Operators (frequencies, roles, portal uploads)source: NYC Health, Cooling Tower Registration and Maintenance (monthly sampling from 8 May 2026, hyperhalogenation)source: NYC Health press release, New cooling tower Legionella testing regulations take effect (8 May 2026)source: NY State Department of Health, Protection Against Legionella: Cooling Tower Requirementssource: CDC, Controlling Legionella in Cooling Towers (control toolkit module)source: HSE (UK), Testing and monitoring your water system for legionella

Where it breaks

Where spreadsheets and generic software fall over

The schedule still says 90 days. NYC changed Legionella sampling to every 31 days on 8 May 2026 and many service calendars were never updated.

Hold the sampling interval on each tower as a rule tied to its jurisdiction, so a change in the law is one edit, and flag any NYC tower with no sample in 31 days while its operation period is open.

A high Legionella result arrives by lab email on a Friday night and nobody starts the 24-hour clock.

Results come into the tower record from the lab, are graded against the local table automatically, and open a corrective action with its deadlines (24 h disinfect, 48 h remediation, 24 h notice, retest in 3 to 7 days) assigned to a named person.

Building staff log readings on a paper sheet in the mechanical room and the treater sees them a week later, if at all.

Give the Responsible Person a phone checklist for the three-times-a-week readings with the tower's limits built in, so an out-of-range pH or residual alerts the treater the same day, and missing readings show before an inspector finds the gap.

Chemical addition records do not meet the rule: no product purpose, no time, no amount, no SDS.

Make every addition a structured entry (product from the tower's approved list, purpose, amount, time, applicator with 7G number), with the SDS attached to the product, so the record exists the moment the chemical goes in.

Partial operation and standby cells: an extra chiller or cell comes online after weeks stagnant and is never treated first.

Track cells and components separately with their own startup dates, and block marking a component online until its pre-start disinfection or treatment adjustment is recorded, as NYC expects for components brought online later.

Records live in the treater's laptop, the controller cloud, the lab portal and a binder, and the owner cannot produce them when the inspector asks.

Keep one record per tower holding the plan, readings, controller exports, lab reports, corrective actions and declarations, with an owner-facing view and a one-click 3-year export.

Checklist

The cooling tower water treatment operations checklist

Print it, or hand it to whoever runs the office side.

  • Every tower has a current water management program or MPP, with its plan version and certifying Qualified Person
  • Sampling interval set per jurisdiction (NYC 31 days since 8 May 2026)
  • Startup and shutdown dates logged and reported within 5 days where required
  • pH, temperature, conductivity and halogen or ORP logged 3 times a week with no 3-day gaps
  • Weekly dip slide or HPC with incubation times recorded
  • Legionella samples taken at least 1 hour after biocide feed, from plan sample points
  • Results graded against the right table (NYC 10/100/1,000, NY State 20/100/1,000)
  • Corrective actions dated, with retests until the result clears
  • Results of 1,000 CFU/mL or more reported within 24 hours
  • Summertime hyperhalogenation done Jul 1 to Aug 31 with retest and declaration
  • Cleaning at least twice a year recorded with photos
  • Every chemical addition recorded with product, purpose, amount, time and SDS
  • Biocide applied only by a 7G certified applicator in New York
  • Annual certification filed by November 1, records kept 3 years

Software options

What software cooling tower water treatment companies actually use

Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.

Aliquot (AquaPhoenix Scientific)

Water treatment companies that want service reports, field data and site history in a tool made for the water industry.

Cloud platform with offline mobile capture for cooling towers, boilers and other water systems, bringing field data, service reports, scheduling and site history together.

source: Aliquot (AquaPhoenix Scientific)

MyTechReports (Advantage Controls)

Treaters who mainly need a service report SaaS built by water treatment people.

Cloud service reporting from Advantage Controls, which also sells WebAdvantage remote monitoring for its controllers.

source: MyTechReports (Advantage Controls)

Controller cloud platforms (e.g. WebAdvantage)

Every treater with networked controllers; usually used alongside a reporting tool.

Live conductivity, pH, ORP, feed and alarm data from the controller with remote access. Strong on readings, not built to run visits, lab results, corrective actions or certifications.

source: Controller cloud platforms (e.g. WebAdvantage)

Oxmaint

Facility maintenance teams that keep the cooling tower logbook in their own CMMS while a contractor does the chemistry.

CMMS with cooling tower chemistry log templates and limit-breach tracking; general facilities software, not a water treater's business system.

source: Oxmaint

Fieldproxy

Water treatment companies and consultants that want towers, plans, route visits, lab results, corrective actions and owner reports in one system set up around their jurisdictions.

Set up for you around your plans and service report format; controller and lab data come in through the open API or file import.

source: Fieldproxy

Published prices, compared:source: AquaPhoenix Scientific, Aliquot: reporting software for the water industrysource: Advantage Controls, Digital platforms (WebAdvantage remote monitoring, MyTechReports)source: Oxmaint, Free cooling tower chemistry log template and CMMS playbook

Questions to ask any vendor

  • Can each tower carry its own control limits and its jurisdiction's sampling interval, and flag a missed 31-day sample?
  • When a Legionella result arrives, does it grade it against the local table and open a corrective action with 24 and 48 hour deadlines?
  • Can building staff log readings three times a week on a phone, against the tower's limits, without a full app login?
  • Does every chemical addition record product, purpose, amount, time, applicator and SDS?
  • Can it track towers, cells and components separately for startup, partial operation and shutdown?
  • Can the owner pull 3 years of records for one tower in one export when the inspector asks?

Bring one real cooling tower water treatment job. We show it running in Fieldproxy.

Get Demo

How Fieldproxy is set up for this

Cooling tower water treatment on Fieldproxy: built around how you already work

A Fieldproxy setup for a cooling tower water treatment company is built around the tower and its plan: each tower holds its limits, sample points and the rules of its city or state, every reading and lab result is checked against them, and anything out of range opens the corrective action the local table requires, with its clock running.

Module 1

Building, system and tower register

Rules, limits and records attach to a system and its towers and cells, not to the customer account.

  • Record: Building (owner, property manager, NYC and NY State registration numbers, jurisdiction: NYC, NY State, Quebec, Vancouver, UK, other)
  • Child record: System (system ID, open or closed circuit, volume, make-up source, operation period, startup and shutdown dates)
  • Child records: Tower and cell, chiller, heat exchanger, controller, feed pump, sample point (name, location, as listed in the plan)
  • Roles per system: Qualified Person, Responsible Person(s), applicator with 7G number and expiry, lab
How this works

Module 2

Water management plan and control limits

Every reading and result is judged against the tower's own plan, and the plan itself has to be current and certified.

  • Plan record: version, ASHRAE 188 edition, Qualified Person, certification date, next certification due (e.g. before startup)
  • Control limits per system: pH range, conductivity set point and target cycles, free halogen or ORP target, inhibitor residual, temperature
  • Jurisdiction rule set: Legionella interval (NYC 31 days), action table (NYC Table 8-1 or NY State Appendix 4-A), dip slide action level, notification clock
  • Rule: a system cannot be marked in operation until the plan is certified and startup cleaning and disinfection are recorded
How this works

Module 3

Recurring visit and sampling schedule

Readings, dip slides, Legionella samples, 90-day inspections, cleanings and hyperhalogenation all run on different clocks.

  • Generated per system from its rule set and operation period: readings 3x weekly, dip slide weekly, Legionella every 31 days (NYC), compliance inspection every 90 days, cleaning twice yearly
  • Seasonal jobs: startup (clean and disinfect within 15 days before heat load, Legionella 3 to 14 days after), summertime hyperhalogenation Jul 1 to Aug 31 with retest 3 to 31 days later
  • Next due computed from the last completed task, not the last scheduled one
  • Routes built by area for technicians covering many buildings
How this works

Module 4

Technician and building staff app

Readings taken by building staff between visits count as much as the technician's.

  • Reading form per sample point: pH, temperature, conductivity, free halogen or ORP, make-up and blowdown meter, time; limits shown, out-of-range highlighted
  • Weekly visual checklist: drift eliminators, fill, basin, biofilm, controller alarms, pumps, with photos
  • Dip slide entry with incubation start and end and result
  • Chemical addition entry: product from the approved list, purpose, amount, time, applicator; SDS linked
  • Offline in mechanical rooms and on roofs, synced when back in signal
How this works

Module 5

Legionella samples, lab results and chain of custody

The sample is only valid if it was taken at the right point and time and the result reaches the right person fast.

  • Sample record: system, sample point, time, minutes since last biocide feed (block if under 60), lab, chain of custody number
  • Lab result imported or entered: CFU/mL, serogroup if reported, date received; graded automatically against the system's table
  • NYC: sample date reporting task due 5 days after collection, assigned to the Qualified Person
How this works

Module 6

Corrective action workflow

The local table already says what to do and by when; the system makes sure it happens and is written down.

  • Opened automatically from a Legionella or dip slide result at or above the action level
  • Steps by level (NYC example): disinfect within 24 h, review treatment, visual inspection at 100+, full remediation within 48 h and city notice within 24 h at 1,000+, retest in 3 to 7 days
  • Each step records time, person, biocide, dose (e.g. 5 to 10 ppm free halogen), contact time and pH
  • Status: Open, Disinfected, Remediation done, Retest pending, Cleared (result under the level-1 threshold), Escalated
How this works

Module 7

Chemical program, inventory and pricing

The chemical program is most of the revenue, and every drum has to be traceable to a tower and a record.

  • Product catalog with registration status (e.g. DEC-registered biocides for New York), SDS, unit, price
  • Drums and totes by site, usage per system from addition records and controller feed data
  • Proposals for new accounts: program, monthly service fee, lab fees, cleanings, remediation rates
How this works

Module 8

Service reports, declarations and owner portal

The building owner is legally responsible and needs to see, and be able to produce, every record.

  • Service report per visit from your template: readings vs limits, chemicals added, dip slide, observations, photos, recommendations
  • Declarations and certifications: hyperhalogenation declaration (due 30 days after), annual certification (due Nov 1), startup and shutdown notices
  • Owner portal per building: current status by system, open corrective actions, last Legionella result, 3-year record export
How this works

Module 9

Compliance dashboard and invoicing

A treater with hundreds of towers needs to see which ones are drifting out of compliance before an inspector does.

  • Board: towers with missed readings, samples due in 7 days, open corrective actions by age, plans due for certification, 7G certifications expiring
  • Invoices for monthly program, visits, lab fees, cleanings and remediation; synced to QuickBooks or Xero
How this works

The AI agents, set up for cooling tower water treatment companies

AgentWhenWhat it doesWhat you get
Watcher agentA reading falls outside the tower's limits, a Monday-Wednesday-Friday reading is missing, or an operating NYC tower reaches day 25 (e.g.) with no Legionella sampleChecks the reading against the system's plan limits and the jurisdiction's schedule, and looks for an open corrective action on the same systemAn alert to the treater and the building's Responsible Person, or a sampling job created with its due date
Document intelligence agentA lab emails a Legionella or HPC report as a PDFReads the system, sample point, date and CFU/mL, matches it to the open sample record and grades it against the local tableThe result on the tower record and, at or above the action level, a corrective action with its 24 h, 48 h and retest deadlines
Vision agentA technician photographs a dip slide, a controller screen or a meterReads the dip slide density against the kit chart, or the conductivity, pH and ORP shown on the controllerFilled reading fields on the visit, flagged if outside the tower's limits
Scheduler agentEvery Monday at 7:00 (e.g.) and on October 1 for certification seasonPulls samples due this week, open corrective actions, missed readings, plans due for certification and towers missing their summertime hyperhalogenationAn emailed briefing per technician and a certification readiness list per building
Text agentA building engineer texts asking about a tower, for example the last Legionella result or when the tech is comingLooks up the system's latest result, open actions and next scheduled visitA reply with the real dates and results from the tower record
AutopilotA building has not signed off a service report, or the owner has not filed the annual certification or hyperhalogenation declaration with two weeks (e.g.) to goDrafts the reminder with the system ID, due date and the documents ready to fileA follow-up email a person approves before it sends

Straight answers

Cooling tower water treatment: FAQ

What software do cooling tower water treatment companies use?

Usually a controller cloud platform for live readings and feed (such as Advantage Controls' WebAdvantage), a water treatment service report tool such as Aliquot from AquaPhoenix or MyTechReports, a lab portal for Legionella results, and spreadsheets in between. Facility teams sometimes keep the logbook in a CMMS such as Oxmaint. Fieldproxy is one option for the treater's own system, built around towers, plans, lab results and corrective actions.

How often must cooling towers be tested for Legionella in New York City?

At least every 31 days while the tower is operating, since 8 May 2026 (it was every 90 days). Also within 3 to 14 days of startup, 3 to 31 days after the summertime hyperhalogenation, and when corrective actions require it. The sample date must be entered in the city portal within 5 days.

What happens if a cooling tower Legionella result is 1,000 CFU/mL or more in NYC?

Under Table 8-1, biocide is increased within 24 hours, the tower is fully remediated within 48 hours (hyperhalogenate, drain, clean and flush), the treatment program is reviewed, the water is retested in 3 to 7 days, and the result is reported to the Health Department within 24 hours of receiving it.

What are NY State's Legionella action levels for cooling towers outside NYC?

Under Appendix 4-A, under 20 CFU/mL means maintain the program; 20 or more means online disinfection and a retest in 3 to 7 days; 1,000 or more means online decontamination at 5 ppm free halogen for at least an hour, notifications, and system decontamination if a retest stays at 1,000 or more.

What is summertime hyperhalogenation?

A one-time high-level halogen treatment NYC requires in every operating cooling tower between July 1 and August 31, dosing 5 to 10 ppm free halogen for at least an hour at a suitable pH, followed by a Legionella test 3 to 31 days later and a declaration in the portal within 30 days.

How often must cooling tower water chemistry be checked?

In NYC, pH, temperature, conductivity and biocide residual at least three times a week with no more than two days in a row between readings, plus a weekly dip slide or HPC and a weekly visual check. Elsewhere the water management program sets the frequency; CDC advises adjusting it to how stable the readings are.

Who can add biocide to a cooling tower in New York?

A commercial pesticide applicator or technician certified in category 7G (cooling towers) by the NYS Department of Environmental Conservation, using DEC-registered biocides. This applies to routine treatment and to disinfection.

What is ASHRAE 188 and do cooling towers need it?

ASHRAE 188 sets minimum requirements for legionellosis risk management in building water systems, including a water management program. It is voluntary unless adopted; New York State requires cooling tower Maintenance Program and Plans to be developed in accordance with it.

How long must cooling tower records be kept?

In NYC at least 3 years, covering maintenance, inspections, deficiencies, corrective actions, water treatment, test results, cleaning and disinfection. Not producing a required record on request is treated as evidence it does not exist.

How is the UK different?

HSE's L8 Approved Code of Practice and HSG274 Part 1 apply. HSE expects routine Legionella testing of cooling towers at least quarterly, sampled to BS 7592 with biocide neutralised where possible and tested by a UKAS-accredited lab.

Related guides

All sources on this page (28)

Run cooling tower water treatment work the way it actually runs.

A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.

Get a walkthrough

One price per company. Unlimited users.