Guide for water treatment dealers ยท checked 16 November 2026
Water treatment dealer software that runs salt routes, rentals, exchange tanks and sizing
A water treatment dealer sells one box and then services it for ten years: salt drops, resin, membranes, rental billing, exchange tanks swapped on a schedule. The money is in the route and the contract, not the install. This guide covers how the sizing math works, the NSF/ANSI 44 efficiency numbers, who needs a licence in Texas, California and Minnesota, why some cities ban salt-regenerating softeners, and how to set a dealer up so every unit, tank and delivery is on file.
See your own jobs set up this way
A 30-minute call. We show you water treatment dealers workflows running in Fieldproxy, built around how you work.
Short answer
Water treatment dealers mostly use either a dealer-specific system or a general field service tool adapted for recurring work. Watertight is built for the industry and covers sales, routes, rentals and leases, recurring billing and inventory, and says many Culligan, EcoWater, Kinetico, RainSoft and WaterCare dealers use it. ServiceTitan publishes a Kinetico dealer playbook for salt delivery routes and automatic rental billing. Smaller dealers use QuoteIQ, Jobber, Housecall Pro or Google Workspace with QuickBooks. Whatever you pick, check that it holds the water test, the sizing sheet, the installed unit with its resin and salt settings, the rental contract and the tank exchange schedule. Fieldproxy is one option. Best for processes that don't fit a template, set up for you: each customer carries their water analysis, their units, their salt route stop and their contract.
3,350
Grains of hardness removed per pound of salt: the NSF/ANSI 44 minimum for an efficiency-rated softener (4,000 for California)
source: WaterWorld (NSF International), Water softening: evaluating efficiency (NSF/ANSI 44)
5 gallons
Or less of regeneration water per 1,000 grains removed, the water efficiency limit in the same rating
source: WaterWorld (NSF International), Water softening: evaluating efficiency (NSF/ANSI 44)
C-55
California licence class (or C-36 plumbing) that must sign the certification form filed with the permit office for a residential softener
source: California Health and Safety Code 116795 (installer certification form), via FindLaw
3 classes
Texas Water Treatment Specialist licence: Class I tank exchange only, Class II install and service, Class III adds RO and DI; 12 CE hours
source: Texas TCEQ, Water Treatment Specialist license (30 TAC Chapter 30, Subchapter H)
How a job runs
One water treatment dealers job, from first call to paid
The order the work really happens in, and what has to be written down at each step so nothing is argued about later.
- 1
Test the water, in the house and at the tap
Start with a hardness reading, then the things that change the sizing: iron, manganese, chlorine or chloramine, pH, TDS, and whether the supply is city or a well. Note the household: people, bathrooms, water heater, irrigation, whether there is a septic tank. A sales rep who only tests hardness will undersize on a well.
- 2
Size the softener from compensated hardness
Nelsen's method: convert ppm hardness to grains per gallon by dividing by 17.1, add 4 grains per ppm of iron, multiply by daily use (75 gallons per person is the figure it uses), then by the days you want between regenerations (3 to 5 is typical) and round up to the next tank size. Most softeners are rated for about 2 ppm of ferrous iron; above that the unit needs a different treatment first.
- 3
Quote the system, the install and the plan
Softener, pre-filter or iron filter, carbon for chlorine, a drinking water RO, bypass and fittings, drain run and electrical. Then the part that pays for years: a salt delivery plan, a filter and membrane schedule, or a rental. Show the customer the monthly number, because rentals and service plans are bought on the monthly figure.
- 4
Check the local rules before anything is ordered
Whether the town allows self-regenerating softeners at all, whether a permit or a licensed installer is needed, and what the drain must discharge to. California, for example, only allows a residential softener to discharge to the sewer if it is demand-initiated, certified for salt efficiency and installed with water-saving devices. A banned job is cheaper to find out about at the quote than at the install.
- 5
Install, set the valve, and record the settings
Plumb it in with a bypass, run the drain with an air gap, set the hardness, salt dose, regeneration trigger and reserve on the control valve, load the resin and salt. Record the serial numbers, the valve settings and the first hardness reading at the tap, because the first service call will start from them.
- 6
Start the recurring stops: salt, filters, membranes
The unit goes onto a route. Salt customers are sorted by how fast they burn it, not by the calendar. Filter and membrane changes follow the manufacturer's schedule and the customer's water. Each stop records bags delivered, the brine tank level, a hardness test at the tap, and anything unusual.
- 7
Bill the rental or contract every month
Rentals and service plans bill on a card or bank draft every month, with a contract start, a term, a price change date and an equipment owner. The dealer owns the equipment; the record has to say so, along with where it is. Failed payments need a path that ends in a recovered unit, not a silent write-off.
- 8
Swap exchange tanks for commercial and industrial customers
A portable exchange tank is delivered full and the exhausted one is taken back to a central regeneration facility. Puretec describes service teams that install, service and replace exhausted softening and deionization tanks on a schedule, with no capital cost to the customer. Each tank has an ID, a customer, a last swap date and a quality reading.
- 9
Service and re-test every year
Sanitize the resin bed, clean the brine tank, check the injector and the valve, test hardness before and after, replace carbon and sediment cartridges, and update the customer's analysis. A year-old analysis is the starting point for the upsell and for the warranty call.
What to record
The fields every water treatment dealers job should capture
Water analysis, per site
- Source: city, private well or both, and the date, the tester and the kit or meter used
- Hardness (ppm or gpg), iron, manganese, chlorine or chloramine, pH, TDS, nitrates where relevant
- Compensated hardness, with the iron factor used (e.g. 4 grains per ppm)
- Household: people, bathrooms, water heater type, irrigation, septic or sewer
- Photos of the incoming plumbing, the available floor space, the drain and the electrical outlet
Installed unit
- Model, serial number, tank size, resin type and age, valve type, install date, installer and their licence number
- Control settings: hardness, salt dose, regeneration trigger (demand or timer), reserve, backwash and rinse times
- Drain run, air gap photo, permit number where one was required
- Rated capacity and salt efficiency from the model's data sheet
- Warranty start, tank warranty and parts warranty terms
Route stop, per visit
- Bags delivered by salt type (sodium chloride pellets, potassium chloride, block), brine tank level before and after
- Hardness at the tap after the unit, in ppm or gpg
- Regeneration count or water meter reading from the valve, if it logs them
- Cartridges and membranes changed, with date and part numbers
- Customer note, photo, signature and the next due date
Rental and tank exchange
- Contract: start date, term, monthly rate, price change date, payment method, who owns the equipment
- Equipment tag, location, install date and the date it should be inspected or swapped
- Exchange tank ID, media type (softening, deionization, carbon), last swap date, outlet quality reading
- Failed payment log and the recovery steps taken
- End of contract: pickup, buyout or renewal, with the resin condition noted
Rules and standards
The rules that shape the work, with their sources
| Rule | What it means on the job |
|---|---|
| What NSF/ANSI 44 measures for a softener | Per an NSF International author in WaterWorld: the standard covers residential cation exchange softeners and the efficiency rating applies only to demand-initiated regeneration units. Salt efficiency must be at least 3,350 grains of hardness removed per pound of salt, or 4,000 for units rated for California, and water efficiency must be 5 gallons or less of regeneration water per 1,000 grains removed. The article is from 2015, so confirm the current edition. source: WaterWorld (NSF International), Water softening: evaluating efficiency (NSF/ANSI 44) |
| Why demand-initiated regeneration matters | EPA's WaterSense sheet says softeners that use demand-initiated regeneration are more efficient than ones on a fixed schedule, and that softeners are not necessary in all homes: they should be considered in areas of substantial hardness or where manufacturers, codes or utilities recommend them. It also notes some jurisdictions limit them. source: US EPA WaterSense, Water softeners technical fact sheet (EPA-832-F-23-016) |
| California: when a residential softener may be installed | Section 116785: either regeneration happens at a nonresidential facility, or it discharges to the community sewer with demand-initiated regeneration, third-party certified salt efficiency of at least 3,350 grains per pound for units installed from 2000 and 4,000 from 2002, and faucet flow restrictors, shower restrictors, toilet reservoir dams and an untreated outdoor hose-bib line installed at the same time. FindLaw notes its copy may not be current. source: California Health and Safety Code 116785 (residential softener conditions), via FindLaw |
| California: who signs the install | Section 116795: the installation certification must be completed by a contractor holding a Class C-55 water conditioning licence or a Class C-36 plumbing licence and filed with the local agency that issues plumbing permits. It lists the homeowner, the make and model, pounds of salt per regeneration, the salt efficiency rating, the water-saving devices and the licensee's licence number. source: California Health and Safety Code 116795 (installer certification form), via FindLaw |
| Texas: the Water Treatment Specialist licence | TCEQ: anyone who under contract installs, exchanges, connects, maintains or services equipment that alters potable water needs a licence, under 30 TAC Chapter 30, Subchapter H. Class I works under supervision and is limited to portable tank exchange and nonportable tank regeneration. Class II covers install, service and repair but not RO or DI unless supervised. Class III adds RO and DI. Licensed plumbers are exempt. Licences run three years with 12 CE hours. source: Texas TCEQ, Water Treatment Specialist license (30 TAC Chapter 30, Subchapter H) |
| Minnesota: licensed contractors and installers (2009 text) | Section 326B.55 as of 2009: in cities and towns of 5,000 or more, a licensed water conditioning contractor must be responsible for all work, and every installation other than a portable exchange must be done by a licensed contractor or installer. Check the current statute, because this is the 2009 version. source: Minnesota Statutes 2009, 326B.55 water conditioning contractors and installers (2009 text) |
| Why some cities ban salt-regenerating softeners | A dealer blog's account: brine puts chloride into wastewater that treatment plants cannot easily remove, so some cities and sanitation districts restrict or remove self-regenerating salt softeners, with rules that range from new-install bans to removal of existing units. The same sources say some agencies treat portable exchange tank services differently and do not give a rule. These are dealer blogs, not ordinance text, so read the local code. source: SoftPro Water Systems (dealer blog), Why some municipalities ban self-regenerating softeners |
| Where the bans are named | LifeSource Water's 2026 post names California (Santa Clarita, Dixon, parts of Los Angeles County), San Antonio in Texas, and several Arizona and New Mexico municipalities as restricting salt-based units. It cites no ordinance text, so confirm each one with the city or sanitation district before quoting a customer. source: LifeSource Water (dealer blog), Where are water softeners banned (Jul 2026) |
| Salt-free devices are not softeners | University of Nebraska-Lincoln: template-assisted crystallization changes hardness into microscopic crystals instead of removing it, so it does not remove most hardness, and ion exchange is needed for real removal of calcium and magnesium. It says no standardized test procedures exist for these residential devices and calls magnetic treatment unproven. source: University of Nebraska-Lincoln Water, Salt-free water softener alternatives |
| Reagent water grades for lab and industrial customers | ASTM D1193-06 as tabled by Xylem: Type I resistivity at least 18.0 megohm-cm and TOC 50 micrograms per liter or less with a 0.2 micron filter; Type II at least 1.0 megohm-cm, prepared by distillation; Type III at least 4.0 megohm-cm and TOC 200 or less with a 0.45 micron filter; Type IV at least 0.2 megohm-cm, pH 5.0 to 8.0. Deionization exchange tanks serve these customers. source: Xylem, Different types of pure water for the lab (ASTM D1193-06 table) |
| Product certification is separate from dealer credentials | WQA's Gold Seal is third-party testing and certification of products that contact household water, including softeners, to NSF/ANSI standards and others. It certifies the product, not the dealer. Dealer technician credentials are separate WQA titles. source: WQA, Gold Seal product certification |
| WQA technician titles | Titles are Certified Water Representative, Certified Water Specialist, Certified Installer, Certified Treatment Designer, Certified Service Technician and Master Water Specialist. Each needs experience and prerequisite courses, an exam included with training and the WQA Code of Ethics. MWS needs five years and a CWS in good standing. Recertification is every three years. A 2014 announcement set the modular scheme that began in March 2015. source: WQA, Professional certification (CWR, CWS, CI, CTD, CST, MWS requirements) |
Rules vary by state, council and contract. Checked 16 November 2026; confirm against the source for your area before relying on it.
Numbers
Sizing, salt efficiency and licence classes at a glance
Sizing figures follow Nelsen's method and are a guideline; the NSF figures come from an NSF International author's article and the licence rows from TCEQ and the California code. The worked example is arithmetic from those inputs, not a vendor claim.
| Item | Figure | Basis |
|---|---|---|
| ppm to grains per gallon | Divide ppm by 17.1 | Nelsen |
| Iron compensation | Add 4 grains per ppm of ferrous iron | Nelsen (other sources use 5; pick one and write it down) |
| Household use | 75 gallons per person per day | Nelsen |
| Days between regenerations | Typically 3 to 5 | Nelsen |
| Iron limit for a standard softener | About 2 ppm ferrous iron | Nelsen |
| Tank sizes, full salt vs efficient setting | 32k vs 24k grains (9 x 48 in); 48k vs 36k (10 x 54); 64k vs 48k (12 x 48) | Nelsen |
| NSF/ANSI 44 salt efficiency | At least 3,350 grains per pound; 4,000 for California | NSF author, WaterWorld |
| NSF/ANSI 44 water efficiency | 5 gallons or less per 1,000 grains removed | NSF author; EPA WaterSense sheet |
| California install conditions | Demand-initiated, 4,000 grains per pound from 2002, flow restrictors and dams | CA HSC 116785 |
| Texas WTS licence | $111 application, 3 year term, 12 CE hours | TCEQ |
| Type I reagent water | At least 18.0 megohm-cm, TOC 50 ug/L or less | ASTM D1193-06 via Xylem |
| Worked example: 200 ppm hardness, 3 ppm iron, family of 4 | 11.7 + 12 = 23.7 gpg; x 300 gal = 7,110 grains/day | Arithmetic from Nelsen |
| Same example over 4 days | 28,440 grains, so a 32,000 grain tank (efficient 24k is too small) | Arithmetic |
source: Nelsen Corporation, Softener sizing (compensated hardness, 75 gallons per person, regeneration interval)source: WaterWorld (NSF International), Water softening: evaluating efficiency (NSF/ANSI 44)source: US EPA WaterSense, Water softeners technical fact sheet (EPA-832-F-23-016)source: California Health and Safety Code 116785 (residential softener conditions), via FindLawsource: Texas TCEQ, Water Treatment Specialist license (30 TAC Chapter 30, Subchapter H)source: Xylem, Different types of pure water for the lab (ASTM D1193-06 table)
Where it breaks
Where spreadsheets and generic software fall over
The rep tests hardness only, sells a 24k unit to a house on a well with 3 ppm iron, and the resin fouls in a year. The service tech arrives to a customer who feels lied to.
A quote can't be sent until the water analysis has iron, manganese and chlorine filled in, and the sizing sheet shows compensated hardness. An iron reading above the unit's limit adds a pre-treatment line or blocks the quote.
A salt route runs on the calendar: every customer every four weeks. Big households run out in three, small ones have full tanks, and drivers burn fuel visiting the wrong houses.
Each unit has a burn rate from bags delivered and brine level at each stop. The next due date is set from that, and the route is built from what is due, grouped by zone.
A rental customer stops paying. Nobody knows which unit is in which house, so a $900 softener sits in a basement for two years.
Equipment tags are tied to the contract and the address. A failed payment starts a recovery path with dates, and the unit can only be marked written off by an owner after a pickup attempt is logged.
A dealer in California installs a timer softener in a town that restricts them. The customer is cited and wants it removed at the dealer's cost.
The site record carries the local rule. A job in a restricted area needs a demand-initiated or exchange option chosen, the certification form completed with the licensed signer, and the permit number stored before the install is scheduled.
A tech in Texas is sent alone to swap an RO membrane on a commercial system. His licence class is for tank exchange only.
Technician records hold licence class and expiry. Jobs carry a required class, and the Dispatch agent only offers technicians whose licence covers the work, with an alert before CE hours lapse.
Exchange tanks pile up at customers with no record of which is full, which was last swapped and which has dropped in quality. A lab customer finds out when a Type II result fails.
Each tank has an ID and a status (full, in service, exhausted, in regeneration). A swap closes one tank and opens another, with an outlet reading logged, and a missed swap date alerts the dispatcher.
Checklist
The water treatment dealers operations checklist
Print it, or hand it to whoever runs the office side.
- Water analysis on file with hardness, iron, manganese, chlorine and the source (city or well)
- Sizing sheet shows compensated hardness, household use, days between regenerations and the tank chosen
- Local rules checked: brine ban, permit, licensed installer, air gap and drain requirements
- Installer licence class and number recorded where the state requires one
- Control valve settings recorded: hardness, salt dose, trigger, reserve
- Serial numbers, resin type and install date recorded for every unit
- Salt route built from burn rate, not the calendar, and grouped by zone
- Hardness tested at the tap on every visit, before and after the unit
- Filter and membrane schedule set from the manufacturer's data and the customer's water
- Rental and contract records show start, term, rate, price change date and equipment owner
- Failed payment path ends in a recovered unit or an owner write-off, never silence
- Exchange tanks tracked by ID, status, last swap and outlet quality reading
- Annual service booked: resin sanitizing, brine tank clean, injector and valve check, re-test
- Technician licences and certifications tracked with expiry dates
Software options
What software water treatment dealers actually use
Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.
Watertight
Dealer groups running routes, rentals and retail, including many franchised brands
Positions itself as enterprise software for the water treatment industry: sales, field service and routes, retail, rentals and contracts, warehouse and back office, with route optimization, a mobile app, inventory and recurring billing for rentals, leases and service contracts. It says many Culligan, EcoWater, Kinetico, RainSoft and WaterCare dealers use it. Pricing is not published. A deep fit for the industry's own model, with less room to change the process.
ServiceTitan
Larger dealers that want a general platform with a published water playbook
Publishes a Kinetico dealer playbook that includes technician route optimization for salt deliveries and equipment rental memberships with automatic rental billing. A general field service platform adapted for the trade. Pricing is quote-based per technician.
QuoteIQ, Jobber, Housecall Pro, ServiceMonster, Kickserv
Small and mid dealers starting out on recurring jobs
QuoteIQ's own comparison lists prices from $29.99 a month for one user (QuoteIQ), Jobber Core at $49, Housecall Pro Basic at $79, ServiceMonster Basic at $99.99 and Kickserv Start at $60 for five users, all monthly billing. It ranks itself first, so weigh it. Good at quotes, schedules and invoices, thin on water analysis, valve settings and rental equipment ownership.
source: QuoteIQ, Jobber, Housecall Pro, ServiceMonster, Kickserv
Google Workspace plus QuickBooks
Very small dealers with a few hundred customers
A 2017 WaterWorld article says some dealers rely on lower-cost tools such as Google and QuickBooks rather than dealer software. Cheap and flexible; breaks at the point where a route and a rental book can't be kept in a spreadsheet.
MaintainX and asset tools
Industrial water service teams with equipment PMs
Listed in QuoteIQ's comparison with a free Basic plan and an Essential plan at $25 per user per month. A maintenance system for assets and work orders, not a sales, rental or salt route tool.
Published prices, compared:source: Watertight, Enterprise software for the water treatment industrysource: ServiceTitan, Kinetico dealer playbook (salt delivery routes, rental memberships)source: QuoteIQ, Top 8 software for water filtration businesses in 2026 (vendor comparison)source: WaterWorld, Choosing the right software for you (dealer software checklist, 2017)
Questions to ask any vendor
- Can I store a water analysis per site (hardness, iron, manganese, chlorine) and have the sizing calculate compensated hardness and show the tank it picks?
- Can each unit hold its valve settings, resin type and age, serial number and install permit number, and show them to the technician at the next visit?
- Can salt deliveries be scheduled from each customer's burn rate and brine tank readings, not a fixed calendar?
- Can rentals and leases bill monthly by card or bank draft, track equipment ownership by tag and address, and run a recovery path on a failed payment?
- Can portable exchange tanks be tracked by ID and status, with swap dates and outlet readings?
- Can technician licence class and expiry control who can be sent to a job, and can the install certification form be generated for a permit office?
Bring one real water treatment dealers job. We show it running in Fieldproxy.
Get DemoHow Fieldproxy is set up for this
Water treatment dealers on Fieldproxy: built around how you already work
A Fieldproxy setup for a water treatment dealer is built around the customer's water and the unit in their house: each site carries its analysis and sizing sheet, each unit its valve settings and rental contract, each salt stop its burn rate, and each exchange tank its swap history. Gates stop a quote on a well with too much iron, a job in a restricted town without the right option, and a technician whose licence class doesn't cover the work.
Module 1
Leads, water test and sizing sheet
The wrong size is a callback, so the quote starts from the analysis.
- Record: Water analysis per site with source (city or well), hardness, iron, manganese, chlorine or chloramine, pH, TDS, tester and date
- Household fields: people, bathrooms, water heater, irrigation, septic or sewer, floor space, drain location, electrical
- Sizing sheet calculates compensated hardness (ppm / 17.1 plus iron factor), daily grains, days between regenerations and recommended tank
- Rule: iron above the softener limit blocks the quote until a pre-treatment line is added or the lead is flagged
- Status: Lead, Tested, Sized, Quoted, Approved, Scheduled, Installed, On route, Closed
Module 2
Quote, finance and approvals
Customers buy on the monthly price, so the quote shows purchase, rental and plan side by side.
- Quote lines: softener, iron or sediment pre-filter, carbon, drinking water RO, bypass and fittings, drain and electrical, install labor, permit fee
- Three views of the same system: buy, rent (monthly rate and term) and buy with a service plan
- Discount over a set % or a rental under a set term needs an owner sign-off (e.g. 10%, 24 months)
- Quote follow-up through email and text with the sizing sheet attached
- Deposit or first month taken at approval, with card or bank draft stored for rentals
Module 3
Local rules and licensing
Brine bans, permits and licence classes decide whether a job is legal.
- Jurisdiction record: city or district, brine restriction yes or no, permit needed, licensed installer required, drain and air gap notes
- Rule: a job in a restricted area needs a demand-initiated or exchange option chosen before it can be scheduled
- Install certification form generated per job (make, model, pounds of salt per regeneration, salt efficiency, water-saving devices, licensee number) for permit offices that require it
- Technician record: licence class (e.g. Texas Class I, II, III), number, expiry, CE hours, WQA titles
- Rule: a job can only be assigned to a technician whose licence class covers the work
Module 4
Installed units and equipment
A unit is a thing you own or warranty for ten years, so it needs an identity.
- Asset record per unit: model, serial, tank size, resin type and age, valve, install date, location in the house, photo of the install and air gap
- Control settings: hardness, salt dose, regeneration trigger, reserve, backwash and rinse
- Rated capacity and salt efficiency from the data sheet, with the NSF/ANSI 44 claim noted
- Warranty start and term for tank, valve and parts, with the next inspection date
- Equipment owner field: customer or dealer, which drives rental billing and pickups
Module 5
Salt route and recurring service
The route is where a dealer makes or loses its margin.
- Recurring plans by type: salt delivery, filter change, membrane change, annual service, with a due date set from burn rate or the manufacturer's interval
- Burn rate per unit from bags delivered and brine tank levels over the last visits
- Route builder groups due stops by zone and truck load; the day-before text confirms access (gate, garage, dog)
- Salt stock per truck by type: sodium chloride pellets, potassium chloride, block
- Rule: a stop can't close without a brine level reading and a hardness test at the tap
Module 6
Field app: install and service checklists
Settings and readings in the house are the evidence in every later dispute.
- Install checklist: bypass, drain run and air gap photo, valve settings entered, resin loaded, first regeneration, hardness before and after
- Service checklist: sanitize resin, clean brine tank, check injector and valve, replace cartridges and membranes, re-test and update the analysis
- Capture serial numbers and part numbers by photo, signature from the customer, GPS and time stamps
- Offline in basements and rural areas, synced later
- Rule: an install can't close without the valve settings and the first reading entered
Module 7
Rentals, contracts and billing
Monthly recurring revenue needs a contract record and a collections path.
- Contract: start date, term, monthly rate, price change date, autopay method, equipment tags attached, owner
- Invoices monthly from the contract, with QuickBooks or Xero sync
- Failed payment path: retry, text, call task, pickup visit, owner-approved write-off only after a pickup attempt is logged
- Buyout and renewal records at end of term, with resin condition noted
- Retention view: customers by churn risk (late pay, skipped service, no salt drop in 90 days, e.g.)
Module 8
Commercial, exchange tanks and subcontractors
Industrial customers buy swapped tanks and water quality, not a box.
- Exchange tank records: ID, media (softening, deionization, carbon), size, status (full, in service, exhausted, in regeneration), last swap, customer
- Swap schedule by consumption or conductivity reading, with outlet quality logged on each swap (resistivity for DI)
- Customer spec carried on the account (e.g. ASTM D1193 Type II) and a certificate generated for the lab customer
- Drivers and regeneration facility staff as a team; subcontract installers or electricians managed with their own insurance and licence records
- Rule: an exhausted tank older than a set number of days at a customer raises a pickup task (e.g. 7 days)
Module 9
Customer portal and management reporting
Customers want to see their water and their plan; owners want to see margin per route.
- Portal: units, last hardness reading, next salt drop, invoices, a button to request an extra drop or a service visit
- Reports: route cost per stop and per bag, rental revenue and churn, cartridges and membranes due in 30 days, licence and CE expiry, quotes open over 7 days
- Weekly briefing per branch: due stops, open callbacks, failed payments, tanks exhausted
- Callback log by cause (undersized, iron, installation, valve setting, customer misuse) and technician
The AI agents, set up for water treatment dealers
| Agent | When | What it does | What you get |
|---|---|---|---|
| Dispatch agent | A membrane change, a Class III RO service or an exchange tank swap is booked | Reads the job's required licence class, the technician's licence and expiry, truck stock of the right cartridges and the distance from the previous stop | A proposed technician and slot for the dispatcher to approve, with the reason a closer technician was skipped (licence class or missing stock) |
| Watcher agent | A unit's burn rate says the brine tank empties before its next scheduled drop, or an exhausted exchange tank has sat at a customer for more than 7 days | Compares bags delivered and tank level readings with the next due date, and checks tank status and swap dates | An extra stop added to tomorrow's route with the reason, or a pickup task for the exchange tank driver |
| Autopilot | A quote has been open 5 days, a rental payment failed, or a service plan renewal is 30 days out | Drafts the follow-up from the quote, the sizing sheet or the contract history, for a person to approve before it sends | An email or text draft: a quote reminder with the monthly price, a failed payment note with a link to update the card, or a renewal offer |
| Vision agent | A tech photographs the data plate on a unit or a test strip result | Reads model, serial number and date from the plate, and the colour of a test strip against its chart, and fills the fields on the unit record | A filled asset record and hardness or chlorine reading for the technician to confirm |
| Document intelligence agent | A commercial customer sends a water quality report, a lab spec or a purchase order for tank exchanges | Pulls the specified water grade, flow rate, tank size and swap interval from the document and matches it to the media in your catalog | A draft exchange contract and tank schedule for review, with the page each number came from |
| Scheduler agent | Every Monday 7 a.m. and the first day of each month | Reads next week's route load, cartridge and membrane stock, rental invoices, failed payments and licence expiries | A weekly email to the owner with stops by zone, short stock, rentals at risk and licences expiring in 60 days |
Straight answers
Water treatment dealers: FAQ
What software do water treatment dealers use?
Larger dealers often use Watertight, which is built for the industry and says many Culligan, EcoWater, Kinetico, RainSoft and WaterCare dealers use it, or ServiceTitan, which publishes a Kinetico dealer playbook for salt routes and rental billing. Smaller dealers use QuoteIQ, Jobber or Housecall Pro, or Google Workspace with QuickBooks. Fieldproxy is one option when you want the water analysis, unit settings, route stops and contracts built around how your dealership runs.
How do you size a water softener?
Nelsen's method: divide ppm hardness by 17.1 to get grains per gallon, add 4 grains per ppm of iron, multiply by daily use (75 gallons per person) and by the days between regenerations (typically 3 to 5), then round up to the next tank size. For 200 ppm hardness and 3 ppm iron with four people, that is about 28,400 grains over four days, so a 32,000 grain tank.
What does NSF/ANSI 44 certify?
It covers residential cation exchange softeners. An efficiency-rated unit must be demand-initiated, achieve at least 3,350 grains of hardness removed per pound of salt (4,000 for California) and use 5 gallons or less of regeneration water per 1,000 grains removed, according to an NSF International author's article. Check the current edition of the standard.
Do you need a licence to install water softeners?
It depends on the state and sometimes the city. Texas requires a TCEQ Water Treatment Specialist licence with three classes and 12 CE hours, with licensed plumbers exempt. California requires the install certification to be completed by a Class C-55 or C-36 licensee. Minnesota's 2009 statute required licensed contractors or installers in cities of 5,000 or more, except portable exchanges. Check your own state.
Are salt water softeners banned anywhere?
Not statewide in California, but some cities and sanitation districts restrict self-regenerating salt softeners because of chloride in wastewater. Dealer blogs name Santa Clarita, Dixon and parts of Los Angeles County, San Antonio, and some Arizona and New Mexico municipalities. They do not cite ordinance text, so read your local code. California law sets conditions for installs that discharge to a sewer.
What is the difference between a softener and a salt-free conditioner?
A softener removes calcium and magnesium by ion exchange and regenerates with brine. Template-assisted crystallization turns hardness into microscopic crystals and does not remove most of it, according to University of Nebraska-Lincoln, which also says no standardized test procedures exist for these residential devices. If the customer needs real hardness removal, they need ion exchange.
How does a water softener rental business make money?
Through monthly recurring billing on equipment the dealer owns, plus salt, filter and service on the same customer. That makes the contract record, the equipment tag and the failed payment path important. If a unit can't be found when a customer stops paying, the dealer has lost the equipment as well as the revenue.
What are exchange tanks?
Portable softener, deionization or carbon tanks that a dealer delivers full and takes back exhausted for regeneration at a central facility. Puretec describes teams that install, service and replace exhausted tanks on a schedule with no capital investment for the customer. In Texas, tank exchange is the work a Class I specialist may do under supervision.
What water grades do labs ask for?
ASTM D1193-06 defines Type I through IV. Type I needs resistivity of at least 18.0 megohm-cm and TOC of 50 micrograms per liter or less, Type II at least 1.0, Type III at least 4.0 and Type IV at least 0.2, per a Xylem table. A deionization exchange tank program should log resistivity at each swap.
What WQA certifications should a dealer's technicians hold?
WQA offers Certified Water Representative, Certified Water Specialist, Certified Installer, Certified Treatment Designer, Certified Service Technician and Master Water Specialist titles, each with experience, courses, an exam and the Code of Ethics, with recertification every three years. Gold Seal is separate: it certifies products, not dealers.
Related guides
All sources on this page (26)
- source: WaterWorld (NSF International), Water softening: evaluating efficiency (NSF/ANSI 44)
- source: California Health and Safety Code 116795 (installer certification form), via FindLaw
- source: Texas TCEQ, Water Treatment Specialist license (30 TAC Chapter 30, Subchapter H)
- source: US EPA WaterSense, Water softeners technical fact sheet (EPA-832-F-23-016)
- source: California Health and Safety Code 116785 (residential softener conditions), via FindLaw
- source: Minnesota Statutes 2009, 326B.55 water conditioning contractors and installers (2009 text)
- source: SoftPro Water Systems (dealer blog), Why some municipalities ban self-regenerating softeners
- source: LifeSource Water (dealer blog), Where are water softeners banned (Jul 2026)
- source: University of Nebraska-Lincoln Water, Salt-free water softener alternatives
- source: Xylem, Different types of pure water for the lab (ASTM D1193-06 table)
- source: WQA, Gold Seal product certification
- source: WQA, Professional certification (CWR, CWS, CI, CTD, CST, MWS requirements)
- source: Nelsen Corporation, Softener sizing (compensated hardness, 75 gallons per person, regeneration interval)
- source: Watertight, Enterprise software for the water treatment industry
- source: ServiceTitan, Kinetico dealer playbook (salt delivery routes, rental memberships)
- source: QuoteIQ, Top 8 software for water filtration businesses in 2026 (vendor comparison)
- source: WaterWorld, Choosing the right software for you (dealer software checklist, 2017)
Run water treatment dealers work the way it actually runs.
A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.
Get a walkthroughOne price per company. Unlimited users.