Guide for hydrant flow testing and valve exercising contractors ยท checked 29 November 2026

Hydrant flow testing and valve exercising, hydrant by hydrant, turn by turn, for the utility and the ISO grader

A city with 2,500 hydrants and 9,000 valves hires a contractor to open every hydrant, flow test a share of them, paint the bonnets by class, and turn every valve in the system closed and back open while counting the turns. The output is not a pretty report. It is a GIS-ready record per asset that the utility, the fire department and the ISO grader all read. This guide covers NFPA 291 flow tests and color coding, NFPA 25 for private hydrants, AWWA valve exercising programs, ISO credit, real contract terms, and how to set up software around it.

See your own jobs set up this way

A 30-minute call. We show you hydrant flow testing and valve exercising contractors workflows running in Fieldproxy, built around how you work.

Book your demo

A video call with our team

Number of employees

Short answer

Hydrant flow testing and valve exercising contractors usually work to the utility's GIS (often Esri ArcGIS), a work order system the utility already owns such as Trimble Cityworks, and the valve machine's own logging software such as Wachs Vitals for torque and turn counts. Fire departments keep hydrant checks in tools like First Due. Fieldproxy is one option for the contractor's own system: a register of hydrants and valves imported from the utility's GIS, mobile screens for inspection, flow tests and exercising with the math built in, defects that become repair jobs, and weekly deliverables in the format the utility's GIS expects.

20 psi

Residual pressure at which a hydrant's rated flow is stated for NFPA 291 color coding and for ISO credit

source: University of Tennessee MTAS, Marking All Fire Hydrants (NFPA 291, 2025 edition, Table 5.1), reviewed Jul 2026

1,500 gpm

Flow at 20 psi that makes a hydrant Class AA, with a light blue bonnet and caps

source: University of Tennessee MTAS, Marking All Fire Hydrants (NFPA 291, 2025 edition, Table 5.1), reviewed Jul 2026

40 points

Share of a community's ISO Public Protection Classification grade based on water supply, including hydrant inspection and flow testing

source: Verisk ISO PPC, Water Supply Evaluations (FSRS)

1 in 5 years

Ohio EPA's recommended goal for exercising 100% of a system's valves, with critical valves every year

source: Ohio EPA Division of Drinking and Ground Waters, Valve Exercising Program Guidance (Sep 2024, citing AWWA G200-15 4.2.5 and M44)

How a job runs

One hydrant and valve service job, from first call to paid

The order the work really happens in, and what has to be written down at each step so nothing is argued about later.

  1. 1

    Load the asset list from the utility's GIS

    The utility hands over its hydrant and valve layers: IDs, locations, main size, valve size, type and last known condition. Wilmington, Delaware gave its contractor the data for about 400 miles of main, 2,500 hydrants and 9,000 valves, and warned that hydrants of certain makes were known to cause problems when operated. Lost valves, paved-over boxes and missing hydrants are flagged before the crews go out.

  2. 2

    Plan routes and warn customers

    Work is grouped by pressure zone and map grid so crews do not stir up the same main twice. Flushing a hydrant moves sediment and brings brown water complaints, so the utility and the affected customers are told before work starts. Wilmington's RFP made the contractor help with customer outreach for scheduled work and emergencies.

  3. 3

    Inspect and operate each hydrant

    Clear vegetation (Wilmington's contractor cleared a 3 foot radius), remove caps and check threads, lubricate, open the hydrant slowly and flow it until the water runs clear, check the stem and look for leaks under pressure, close slowly, then confirm the barrel drains. Under NFPA 25 the flow lasts at least 1 minute and a dry barrel must drain within 60 minutes. Mueller adds that the auxiliary valve tied to the hydrant should be exercised at the same time, and that a hand held over an open nozzle should feel slight suction as the barrel drains.

  4. 4

    Run the two-hydrant flow test

    Put a gauge on the residual hydrant and read static pressure. Open a flow hydrant nearby, read the pitot pressure at a 2.5 inch outlet, and read the residual pressure at the first hydrant while water flows. Convert pitot pressure to gpm with Q = 29.84 x c x d squared x the square root of p, then project the flow available at 20 psi. City contracts such as Woodstock, Georgia's name the two-hydrant method.

  5. 5

    Classify and paint

    Classify the hydrant from the flow at 20 psi, not the flow seen during the test: Class AA (1,500 gpm or more) light blue, A (1,000 to 1,499) green, B (500 to 999) orange, C (below 500) red, painted on the bonnet and caps. MTAS notes that skipping the projection to 20 psi can change the color on up to half the hydrants in a system.

  6. 6

    Exercise the valves

    Find and clean the valve box, then close the valve with a steady, low torque: five to 10 turns, back two or three, forward again, until it seats. Open it a few turns to scour the seat, close it again, then open fully, counting turns both ways. Truck-mounted machines record turns and torque per valve; Wachs Vitals stops or reverses automatically when a preset torque limit is hit.

  7. 7

    Log defects and repair what is in scope

    Broken stems, operating nuts that spin, hydrants that will not drain, cracked barrels, leaking gaskets, damaged breakaway flanges and valves that will not seat each become a defect with photos. Minor repairs (caps, gaskets, chains) are done on the spot; replacements and multi-valve shutdowns are quoted or done on the utility's time and materials schedule.

  8. 8

    Deliver the weekly GIS update

    Each week the utility gets the hydrants and valves worked, their condition, any found in non-normal condition, and recommended repairs, in a form its GIS can load. Wilmington asked for coordinates accurate to within 3 feet and data compatible with its ArcGIS system.

  9. 9

    Close out for ISO and the fire department

    At the end of the cycle, report hydrants inspected, flow tested, painted, and out of service, plus valves exercised, inoperable and replaced. ISO gives the same credit whether the fire department or the water provider does the work, so both want the same numbers. Invoice by unit or day rate, and set next year's routes from what is still open.

What to record

The fields every hydrant and valve service job should capture

Hydrant register and inspection

  • Hydrant ID, GIS ID, address or intersection, GPS point (e.g. within 3 feet), pressure zone, main size, lateral size
  • Make, model, year, dry or wet barrel, outlets (number and size, 2.5 inch and 4.5 inch), public or private, auxiliary valve ID
  • Caps and threads, lubrication done, operating nut condition, stem operation, leaks under pressure
  • Flushed minutes, water clear yes or no, discharge point (sanitary, dechlorinated storm, approved other)
  • Barrel drain time, water or ice found, drain plugged and marked for pumping
  • Height of lowest outlet above grade, breakaway flange or bolts condition, clearance cut, paint needed, photos

Flow test

  • Residual hydrant ID and flow hydrant ID(s), date, time, tester, gauge serials
  • Static pressure and residual pressure (psi) at the residual hydrant
  • Pitot reading (psi), outlet inside diameter (in), outlet coefficient (0.9, 0.8 or 0.7), flow (gpm)
  • Projected flow at 20 psi, NFPA 291 class and color, previous test date and result
  • Pressure zone, tank levels and pumps running if recorded by the utility

Valve exercise

  • Valve ID, GIS ID, size, type (gate, butterfly), opens left or right, critical yes or no, normal position
  • Box found, box condition, depth to nut, cleaned yes or no, paved over or buried
  • Turns to close and to open, expected turns, maximum torque, torque chart, machine or hand key
  • Result: operable, hard to turn, does not seat, broken stem or nut, leaking bonnet, left in what position
  • Defect raised, repair quoted, customers affected if isolated, photo

Rules and standards

The rules that shape the work, with their sources

RuleWhat it means on the job
NFPA 291 Table 5.1: hydrant classes and colorsBonnets and nozzle caps are coded by flow available at 20 psi residual: Class AA light blue at 1,500 gpm or more, Class A green at 1,000 to 1,499, Class B orange at 500 to 999, Class C red below 500. Reflective paint is recommended (5.2.1.3) and the rated capacity of high-volume hydrants can be stenciled on top (5.2.1.5). source: University of Tennessee MTAS, Marking All Fire Hydrants (NFPA 291, 2025 edition, Table 5.1), reviewed Jul 2026
NFPA 291 5.2.1.1: barrel colorsPublic hydrant barrels are chrome yellow unless the jurisdiction adopted another color. Private hydrants are painted to stand apart from municipal ones, most often red, and hydrants on non-potable supplies are violet. source: University of Tennessee MTAS, Marking All Fire Hydrants (NFPA 291, 2025 edition, Table 5.1), reviewed Jul 2026
NFPA 25: private hydrants inspected, flowed and lubricated every yearDry barrel and wall hydrants are inspected annually and after each operation (7.2.2.4, 2008 edition), tested annually by opening fully and flowing until clear for at least 1 minute (7.3.2.1 and 7.3.2.2), must drain within 60 minutes (7.3.2.4), and are lubricated annually (7.4.2.1). Where a barrel cannot drain, the drain is plugged, the barrel pumped after use, and the hydrant clearly marked (7.3.2.5 and 7.3.2.6). source: University of Colorado Boulder Fire and Life Safety, Inspection, Testing and Maintenance of Fire Hydrants (NFPA 25 2008, IFC 2009)
AWWA G200-15 4.2.5: written valve exercising programOhio EPA summarizes the standard: follow AWWA Manual M44 and the manufacturer's procedure, set annual goals for transmission and distribution valves, aim to test 100% of valves within a set period (recommended once every 5 years), identify critical valves for regular exercising, track results, set goals to cut the percentage of inoperable valves, and plan replacements. source: Ohio EPA Division of Drinking and Ground Waters, Valve Exercising Program Guidance (Sep 2024, citing AWWA G200-15 4.2.5 and M44)
Which valves count as criticalTransmission valves serving large groups of customers, distribution valves that keep hospitals, dialysis centers, nursing homes and key plants in service, areas prone to main breaks, infrastructure near the end of its life, and valves near road or utility reconstruction. Critical valves are exercised annually. source: Ohio EPA Division of Drinking and Ground Waters, Valve Exercising Program Guidance (Sep 2024, citing AWWA G200-15 4.2.5 and M44)
AWWA closing procedure for an unused valveBegin with steady torque for five to 10 rotations, reverse two or three, go forward five to 10 more, repeat to closure, open a few turns so flow scours the seat, then close fully again. Count turns down and up, use the lowest torque that works, and turn slowly to avoid water hammer. The brief recommends exercising valves annually where possible, or at least every two years. source: National Environmental Services Center (West Virginia University), Tech Brief: Valve Exercising, Summer 2007
ISO FSRS: water supply is 40 pointsTo earn Class 8 or better, a system must deliver at least 250 gpm for 2 hours beyond maximum daily use. Needed fire flows run from 500 to 12,000 gpm and are measured at 20 psi residual. Beyond the hydraulics, ISO grades hydrant type and installation and any program of hydrant inspections and flow testing for extra points. source: Verisk ISO PPC, Water Supply Evaluations (FSRS)
ISO credit does not care who does the workThe same credit for hydrant maintenance, inspection and flow testing is given whether the fire department or the water provider does it. With several water providers, credit is split by the share of hydrants each one supplies. source: ISO Mitigation newsletter, The critical relationship between fire departments and water providers (Spring 2017)
Two-hydrant tests onlyWoodstock, Georgia's contract asks for 20% of its roughly 2,100 hydrants to be flow tested each year using the two-hydrant method, alongside annual inspection, exercising, greasing, isolation valve operation and painting of every hydrant. source: ConstructConnect listing, City of Woodstock GA: Fire Hydrant Flow Testing and Inspections (May 2025)
What a big city valve and hydrant contract looks likeMetro Nashville's RFQ 772180 for a valve exercising program and hydrant flow testing drew three bids from $4,553,550 to $4,920,448. Hydromax USA scored highest (95.46 of 100) on approach, schedule and a detailed data management, database and QA/QC plan, ahead of Wachs Water Services and Utility Service Co., although its price was not the lowest. source: Metro Nashville Purchasing, RFQ 772180 Valve Exercising Program and Hydrant Flow, evaluation and cost sheet
Private hydrants: registered contractors and copies to the fire marshalIn Bellevue, Washington, private hydrants are the property owner's responsibility and may be maintained and tested only by a contractor registered with the fire department. Test records go to the Fire Prevention Bureau and the original stays with the owner. Flush water goes to sanitary sewer, or to storm sewer only if dechlorinated. source: Bellevue Fire Department, Confidence Testing for Fire Hydrants: maintenance, testing and marking of private hydrants
IFC 507.5: hydrants kept operable and visibleHydrant systems are subject to periodic tests the fire code official requires, kept in operating condition and repaired when defective (507.5.2), and nothing may be placed near a hydrant that stops it being immediately seen and reached (507.5.4). source: University of Colorado Boulder Fire and Life Safety, Inspection, Testing and Maintenance of Fire Hydrants (NFPA 25 2008, IFC 2009)
Utility contracts set the data formatWilmington's RFP required electronic records of hydrant ID, size, type and coordinates to within 3 feet, weekly reports listing hydrants and valves in non-normal condition with recommended fixes, and data compatible with the City's ArcGIS system. Valve work had to use a valve machine where needed, with hand keys allowed on free-turning valves. source: City of Wilmington DE, Ordinance 16-010 with RFP for fire hydrant inspection, testing and rehabilitation (Utility Service Co. proposal)

Rules vary by state, council and contract. Checked 29 November 2026; confirm against the source for your area before relying on it.

Numbers

Figures a hydrant and valve crew works to

From NFPA 291 (via MTAS), NFPA 25 (2008 wording via CU Boulder), ISO, Ohio EPA, the AWWA guidance in the NESC brief and real city contracts. Always work to the edition and contract the owner enforces.

ItemFigureSource note
Class AA (light blue)1,500 gpm or more at 20 psiNFPA 291 Table 5.1
Class A (green)1,000 to 1,499 gpmNFPA 291 Table 5.1
Class B (orange)500 to 999 gpmNFPA 291 Table 5.1
Class C (red)Below 500 gpmNFPA 291 Table 5.1
Pitot formulaQ = 29.84 x c x d squared x root pSome sources use 29.83
Outlet coefficient0.9 rounded, 0.8 square, 0.7 projectingFeel inside the outlet
Projection to 20 psiQR = QF x ((Ps minus 20) / (Ps minus Pr)) to the 0.54Hazen-Williams exponent
NFPA 25 flow on a private hydrant1 minute min, yearlyFlow until clear
Dry barrel drain time60 minutes maxElse plug, pump and mark
Bellevue private hydrant flush3 minutes min or until clearOne hydrant at a time
Critical valvesEvery yearOhio EPA
All valves100% within 5 yearsOhio EPA recommended goal
ISO minimum for Class 8 or better250 gpm for 2 hoursAbove max daily use
ISO needed fire flow range500 to 12,000 gpmAbove 3,500 graded per building

source: University of Tennessee MTAS, Marking All Fire Hydrants (NFPA 291, 2025 edition, Table 5.1), reviewed Jul 2026source: QRFS, Pitot gauges: how do I calculate the PSI to GPM conversion? (updated Feb 2026)source: NICET ITWBS study guide 8.4, Water supply flow testing and pitot tube calculationssource: University of Colorado Boulder Fire and Life Safety, Inspection, Testing and Maintenance of Fire Hydrants (NFPA 25 2008, IFC 2009)source: Bellevue Fire Department, Confidence Testing for Fire Hydrants: maintenance, testing and marking of private hydrantssource: Ohio EPA Division of Drinking and Ground Waters, Valve Exercising Program Guidance (Sep 2024, citing AWWA G200-15 4.2.5 and M44)source: Verisk ISO PPC, Water Supply Evaluations (FSRS)

Where it breaks

Where spreadsheets and generic software fall over

Hydrants are painted by the gpm the pitot gauge showed on test day, so a hydrant that would give 900 gpm at 20 psi gets a green bonnet and an engine company counts on 1,000.

Store static, residual and pitot readings and let the screen compute the flow at 20 psi and the NFPA 291 class, so the paint color comes from the projection, not the raw reading.

The valve crew writes 'exercised OK' on 400 valves in a week, and when a main breaks the valve that should isolate it turns 11 times and stops, because nobody recorded that a 12 inch valve needs far more.

Record turns to close and open against the expected count per valve size and make, and flag any valve that seats short as 'does not seat' rather than 'operable'.

A contractor over-torques a valve that has not moved in 20 years and snaps the stem, then the utility finds out from a customer with no water.

Set a torque limit per valve size on the machine and log the torque chart against the valve, so a stalled valve is stopped, recorded and raised as a defect before anyone forces it.

Field notes come back on paper with street names, the GIS team cannot match half of them to hydrant IDs, and the weekly deliverable slips a month.

Work from the utility's own hydrant and valve IDs with GPS points, capture new or misplaced assets with coordinates, and export the week in the layer format the utility loads.

A dry barrel hydrant with a plugged drain is flushed in November and freezes, because the crew that flushed it did not know it had to be pumped.

Keep 'drain plugged, pump after use' as a flag on the hydrant record, show it on the inspection screen, and block closing the visit until the pumped-out box is ticked.

The utility cannot show the ISO grader how many hydrants were inspected and flow tested in the last cycle because the fire department and the contractor kept separate lists.

Keep one hydrant register with every inspection and test dated, and give the fire department a read-only view so both report the same numbers.

Checklist

The hydrant and valve service operations checklist

Print it, or hand it to whoever runs the office side.

  • Hydrant and valve layers imported from the utility GIS with their own IDs
  • Known problem makes and models flagged before anyone operates them
  • Customer notice sent for each flushing or exercising area
  • Each hydrant opened and closed slowly, flowed until clear, drain checked
  • Plugged drains marked and pumped after use
  • Flow tests run with two hydrants, readings stored, flow projected to 20 psi
  • Bonnets and caps painted to the projected NFPA 291 class
  • Auxiliary valve exercised with each hydrant
  • Valve turns counted both ways against expected turns; torque recorded
  • Critical valves on an annual list; whole system on a 5 year cycle
  • Every defect photographed and raised as a repair or replacement
  • Flush water to sanitary sewer or dechlorinated before storm drains
  • Weekly deliverable in the utility's GIS format
  • Cycle summary for the utility, the fire department and the ISO grader

Software options

What software hydrant flow testing and valve exercising contractors actually use

Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.

Wachs Vitals (with Wachs valve exercisers)

Crews running truck-mounted or portable Wachs valve machines.

Vitals Mobile and Vitals Desktop control the machine, record turns and the torque chart per valve, set torque limits with auto shutdown or reverse, and sync to the desktop GIS.

source: Wachs Vitals (with Wachs valve exercisers)

Trimble Cityworks

Utilities that already run their work orders in Cityworks on top of Esri GIS.

Woolpert built a Cityworks configuration that standardizes hydrant flow test data to AWWA guidance and calculates results from a GIS hydrant inventory.

source: Trimble Cityworks

Paper hydrant record cards and spreadsheets

Small water systems, fire districts and private campuses.

State forms such as the North Carolina OSFM hydrant record card hold location, gpm at 20 psi, main size, static, residual and flowing pressures, date and tester. Cheap, but turn counts, defects and repairs end up in separate places.

source: Paper hydrant record cards and spreadsheets

First Due Hydrants

Fire departments that check hydrants and record flow tests themselves.

Records hydrant checks and flow tests, colors hydrants on the map by NFPA 291 after a test, and shows out of service hydrants for pre-planning.

source: First Due Hydrants

Fieldproxy

Contractors that test, flush, paint and exercise for several utilities, fire districts and private owners, and also do the repairs.

Set up for you around your hydrant and valve register, inspection, flow test and exercise screens, defect pricing and each utility's deliverable format; assets come in from the utility's GIS export or the open API.

source: Fieldproxy

Published prices, compared:source: Municipal Sewer and Water, Wachs Vitals software offers precise controlling and recording for valve maintenance (Oct 2023)source: Water Online, Using Trimble Cityworks and Woolpert for hydrant flow testing (May 2024)source: First Due, Hydrants modulesource: North Carolina Office of State Fire Marshal, Hydrant Inspection/Testing data requirements and hydrant record cardsource: Metro Nashville Purchasing, RFQ 772180 Valve Exercising Program and Hydrant Flow, evaluation and cost sheetsource: City of Wilmington DE, Ordinance 16-010 with RFP for fire hydrant inspection, testing and rehabilitation (Utility Service Co. proposal)

Questions to ask any vendor

  • Can it import the utility's hydrant and valve layers and keep their IDs, so the export loads back into their GIS?
  • Does the flow test screen calculate gpm from the pitot reading and project the flow to 20 psi, then set the NFPA 291 class?
  • Can a valve record hold turns both ways, expected turns, maximum torque and a torque chart from the machine?
  • Can it hold flags like 'drain plugged, pump after use' and 'known problem model' and show them to the crew?
  • Can a defect found on a hydrant or valve become a quoted repair or a time and materials job without retyping?
  • Can it produce a cycle summary of hydrants inspected, flow tested and painted, and valves exercised and inoperable, for ISO?

Bring one real hydrant and valve service job. We show it running in Fieldproxy.

Get Demo

How Fieldproxy is set up for this

Hydrant and valve service on Fieldproxy: built around how you already work

A Fieldproxy setup for a hydrant and valve contractor is built around the utility's own assets: every hydrant and valve is a record with its GIS ID, each inspection, flow test and exercise is logged against it with the readings that matter (static, residual, pitot, turns, torque), the 20 psi projection and paint class are calculated on the phone, and every defect carries through to a repair, so the weekly GIS file, the repair quote and the ISO summary come from the same register.

Module 1

Utility, zone and asset register

The utility, the fire department and ISO all talk about specific hydrant and valve IDs.

  • Record: Utility or owner (public utility, fire district, private campus), contract, GIS format, coordinate accuracy required (e.g. 3 feet)
  • Child record: Hydrant (GIS ID, location, zone, main and lateral size, make, model, barrel type, outlets, public or private, auxiliary valve)
  • Child record: Valve (GIS ID, size, type, opens left or right, critical yes or no, normal position, expected turns)
  • Flags: known problem model, drain plugged (pump after use), paved over, lost, out of service
  • Import from the utility's hydrant and valve layers; new assets captured with GPS
How this works

Module 2

Contracts, routes and day rates

City contracts mix per-unit work, day rates and time and materials repairs, often over three to five years.

  • Contract per utility: scope (inspect all, flow test a share such as 20%, exercise critical valves yearly), term and renewals
  • Unit prices per hydrant inspected, flow test, valve exercised, plus crew day rates and repair rate sheets
  • Routes by pressure zone and map grid, with customer notice dates per area
  • Public work flags: prevailing wage, small business participation, certified payroll
How this works

Module 3

Hydrant inspection screen

Most visits are a fixed sequence that must be done the same way every time.

  • Steps: clearance cut, caps and threads, lubrication, open slowly, flow until clear (minutes), stem and leaks, close slowly, drain check
  • Drain time with a 60 minute rule for private hydrants under NFPA 25; plugged drains must show 'pumped' before close
  • Outlet height, breakaway parts, paint needed, photos; auxiliary valve exercised yes or no
  • Discharge point recorded (sanitary, dechlorinated storm, approved other); works offline
How this works

Module 4

Flow test and paint class

The class and color must come from the flow at 20 psi, and ISO wants two-hydrant tests.

  • Residual hydrant and one or more flow hydrants picked on the map; gauge serials recorded
  • Static, residual and pitot readings; outlet diameter and coefficient (0.9, 0.8, 0.7)
  • Calculated flow, projected flow at 20 psi, NFPA 291 class and paint color set automatically
  • Rule: a single-hydrant test cannot be saved as a rated flow test; paint task opens when the class changes
How this works

Module 5

Valve exercise log

Turn counts and torque are the only proof a valve will isolate a break.

  • Box located, cleaned, depth; machine or hand key
  • Turns to close and open versus expected; maximum torque and torque chart from the machine file
  • Result: operable, hard, does not seat, broken stem or nut, leaking bonnet; position left in
  • Rule: a valve that seats short of expected turns is saved as 'does not seat', not 'operable'
How this works

Module 6

Defects, repairs and replacements

Broken hydrants and valves are where the contract grows, and the utility needs a fix list.

  • Defect per asset: type, severity, photo, out of service yes or no
  • Minor repairs done on site from van stock (caps, gaskets, chains, nozzles)
  • Replacement quotes and multi-valve shutdown plans with affected customers listed
  • Repair closes only with a re-operation of the hydrant or a re-exercise of the valve
How this works

Module 7

Weekly deliverable and utility portal

The utility's GIS team needs the week's results in its own format, on time.

  • Weekly export per utility: assets worked, condition, non-normal list, recommended fixes, coordinates
  • Portal: progress by zone, open defects, out of service hydrants, flow test results by class
  • Read-only view for the fire department so hydrant status matches
  • Private hydrant reports sent to the fire marshal where the city requires a copy
How this works

Module 8

Cycle reporting for ISO and capital plans

ISO credit and the utility's replacement budget both come from the cycle numbers.

  • Hydrants inspected, flow tested and painted this cycle; date of last test per hydrant
  • Valves exercised, critical valves done, percent inoperable versus last cycle
  • Inoperable valves and failed hydrants ranked for replacement
  • Exports for the utility's annual report and the ISO review
How this works

The AI agents, set up for hydrant flow testing and valve exercising contractors

AgentWhenWhat it doesWhat you get
Document intelligence agentA utility sends its hydrant and valve export, old inspection sheets or a prior contractor's PDF report.Reads asset IDs, sizes, makes, last test dates and known defects, and matches them to the register.Draft hydrant and valve records with duplicates, missing coordinates and unmatched IDs flagged for review.
Watcher agentA day's results sync from the field.Checks for valves that seated short of expected turns, torque above the set limit (e.g. by valve size), hydrants with drain times over 60 minutes, and painted classes that do not match the projected flow.A list of suspect records on the job for the supervisor to review before the weekly export goes out.
Vision agentThe crew photographs a hydrant's bonnet casting or a valve box lid.Reads make, model and year from the casting, and the current bonnet color.Hydrant make, model and year filled in, with a paint task raised when the color does not match the stored class.
Voice agentThe operator talks at the valve box: 'Valve 4471, twelve inch, 38 turns, hard last five, seats.'Matches the valve, records the turns and result, and notes it against the expected count.The valve exercise record filled in for review, with a 'hard to turn' defect drafted.
Text agentA resident replies to the flushing notice or texts about brown water.Looks up which zone and streets were flushed that day and the planned finish.A reply with the area, the date and advice to run the cold tap, logged on the zone's job.
Scheduler agentEvery Friday afternoon.Gathers each utility's week: hydrants and valves worked, defects found, out of service hydrants, and progress against the contract's share.A weekly summary emailed to the utility contact and the account manager, with the GIS export attached.

Straight answers

Hydrant and valve service: FAQ

What software do hydrant flow testing and valve exercising contractors use?

Most work to the utility's GIS (often Esri ArcGIS) and its work order system, such as Trimble Cityworks, with the valve machine's own software, such as Wachs Vitals, recording turns and torque. Fire departments often use First Due for hydrant checks. Fieldproxy is one option for the contractor's own system: asset register, inspection, flow test and exercise screens, defects into repairs, and weekly GIS deliverables.

What do fire hydrant colors mean?

Under NFPA 291 Table 5.1, the bonnet and caps show the flow available at 20 psi residual: light blue Class AA (1,500 gpm or more), green Class A (1,000 to 1,499), orange Class B (500 to 999) and red Class C (below 500). Barrels are usually chrome yellow for public hydrants, red for private and violet for non-potable supplies.

How is a hydrant flow test done?

With two hydrants. A gauge on the residual hydrant reads static pressure, a nearby hydrant is opened and its pitot pressure read, and the residual pressure is read while it flows. Flow is Q = 29.84 x c x d squared x the square root of p, then projected to 20 psi with the 0.54 exponent. City contracts such as Woodstock, Georgia's specify the two-hydrant method.

How often should hydrants be flow tested?

NFPA 291 sets no interval. NFPA 25 calls for private hydrants to be flowed every year. Utilities set their own share; Woodstock, Georgia flow tests 20% of its hydrants each year while inspecting all of them. ISO grades documented flow testing programs as part of water supply.

How often should water valves be exercised?

Ohio EPA, following AWWA G200, recommends critical valves every year and a goal of 100% of valves within 5 years, with the program tracking and reducing the percentage of inoperable valves. The NESC brief recommends annually where possible, or at least every two years.

How many turns should a gate valve take?

It depends on size and make, so the expected count belongs on each valve record from the manufacturer's data. What matters in the field is counting turns both ways and flagging any valve that seats well short of its expected count, which often means a broken gate or buildup.

Why does hydrant flushing turn tap water brown?

Normal flow moves mostly in the center of the main. High flow from a hydrant stirs up sediment from the pipe walls, which stays suspended until the velocity drops. That is why utilities warn customers and open hydrants one at a time and slowly.

Who maintains private fire hydrants?

The property owner. In Bellevue, Washington, only contractors registered with the fire department may test and maintain them, and copies of the test records go to the Fire Prevention Bureau. NFPA 25 sets the annual inspection, flow and lubrication.

How does hydrant work affect a town's ISO rating?

Water supply is 40 points of the ISO Public Protection Classification. ISO measures available flow at 20 psi against needed fire flow, and adds credit for hydrant type and installation and for documented inspection and flow testing programs, whoever does the work.

Can Fieldproxy produce our utility's GIS deliverable?

Yes. The weekly export is built in each utility's format from the hydrant and valve records, with their own IDs and coordinates, plus the non-normal list and recommended repairs. Asset layers and old reports can be imported.

Related guides

All sources on this page (30)

Run hydrant flow testing and valve exercising work the way it actually runs.

A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.

Get a walkthrough

One price per company. Unlimited users.