Guide for sewer camera inspection and hydro jetting companies ยท checked 20 November 2026
Sewer camera and hydro jetting software built around the segment, the PACP code and the city's spec
A sewer cleaning and CCTV contractor is paid by the linear foot of pipe the owner accepts, manhole to manhole. Acceptance depends on a spec: camera speed, counter accuracy, how long to stop at each lateral, the file name of the video, and a PACP database coded by someone whose NASSCO card has not expired. This guide covers how a clean-and-televise job runs, the NASSCO, OSHA and city rules behind it, private lateral certificates, jetter numbers and published bid prices, and what software the trade uses.
See your own jobs set up this way
A 30-minute call. We show you sewer camera inspection and hydro jetting companies workflows running in Fieldproxy, built around how you work.
Short answer
Sewer CCTV contractors code inspections in NASSCO-certified inspection software, most often WinCan VX, ITpipes, CUES GraniteNet, POSM or PipeTech, because city specs require a PACP exchange database with the video. That software does not run the business: crews and trucks, hydrant permits, confined space records, debris disposal tickets, re-televise punch lists, per-foot billing and private lateral certificates sit in spreadsheets or a general field service tool. Fieldproxy is one option for that operations side. Best for processes that don't fit a template, set up for you: each pipe segment carries its owner's spec, its cleaning and inspection status, its deliverables and its billable footage, next to the PACP software rather than replacing it.
30 ft/min
Maximum camera travel speed in the Corpus Christi, Wauwatosa and San Francisco PUC specs (SFPUC writes it as 0.5 ft per second)
source: City of Corpus Christi TX, Section 027611, Cleaning and Televised Inspection of Conduits
3 years
How long a NASSCO PACP, LACP or MACP certification lasts. There is no grace period: lapse and you retake the initial class
source: NASSCO Policy 14, PACP/LACP/MACP Recertification (January 2024)
5 seconds
Minimum time Toronto requires the camera to stop and view each defect or service connection
source: City of Toronto TS 409, CCTV inspection of sewers (September 2019)
95%
Internal pipe height Columbus requires cleaning to restore in sewers up to 60 in (98% above that)
How a job runs
One sewer camera and hydro jetting job, from first call to paid
The order the work really happens in, and what has to be written down at each step so nothing is argued about later.
- 1
Load the segment list and the owner's spec
The work arrives as a list of pipe segments, each named upstream manhole to downstream manhole with a diameter, material and mapped length. Read the spec before the first setup: PACP version required, camera speed, stop time at defects, counter tolerance, video format and the file name pattern. San Francisco PUC allows only one asset per video survey, and Wauwatosa names each inspection [Upstream Manhole]_[Downstream Manhole].
- 2
Sort out water, traffic and notices
A jet truck needs water. Most utilities want a hydrant meter permit and an approved air gap or backflow preventer on the truck; Windsor no longer allows hydrant taps at all. Pick the MUTCD temporary traffic control layout for each manhole. Where residents have had a toilet blow-back before, Ottawa hand delivers a notice 24 to 48 hours ahead and lowers the cleaning pressure at those addresses.
- 3
Check the manhole before anyone leans in
Sewer manholes are permit-required confined spaces. Most cleaning and CCTV is done from the surface, but if anyone enters, OSHA 1910.146 requires the air to be tested with a calibrated direct-reading instrument for oxygen, then flammable gases, then toxics, in that order, and a retrieval system with a chest or full body harness.
- 4
Clean the segment and catch the debris
Jet from the downstream manhole so debris is drawn back to the vacuum tube. Columbus describes a step process, each step at most 50 ft longer than the last; one full sequence is a pass, and a line still dirty after three passes is reclassified as heavy cleaning. Debris has to come out at the downstream manhole. Passing it to the next segment is not allowed in the Columbus or Corpus Christi specs.
- 5
Televise within the spec
Check the footage counter first: Wauwatosa wants it checked daily against a walking meter and accurate to 1% over the segment. Run the camera no faster than the spec allows, stop and pan at every lateral and defect, and keep the lens clear of flow. Regina caps the water level at 20% of the pipe during inspection, and Wauwatosa bans televising during rainfall.
- 6
Code it in PACP, and handle the abandoned survey
A certified operator fills the header and codes each observation by distance. When the camera cannot pass (debris, high water, an obstruction, a collapsed pipe) the survey is abandoned and coded as such (MSA in PACP), and a reverse setup from the other manhole is attempted. Toronto requires a reversal for every abandonment, with a database comment and a photograph.
- 7
Report what cannot wait
Some findings go to the owner the same day, not in the final package. Toronto's emergency notification list includes a pipe blocked 90% or more, and Corpus Christi requires the contractor to report a sanitary sewer overflow immediately. On a private lateral, a yellow or orange plastic pipe crossing the sewer is a suspected gas cross bore: stop and call the gas utility.
- 8
Decant and dispose
Decanted water goes back to the sewer; solids go to the plant or a landfill the owner accepts. Miami-Dade takes debris at its Class I landfill only when it is at least 20% solids with no visible moisture, and charges the contractor $500 per load for improper disposal. Keep the weigh ticket for every load: Windsor asks for logs and weigh tickets as proof of legal disposal.
- 9
QC and hand over the deliverables
Before submission, check the coding. Ontario's provincial spec requires accuracy verification on at least 10% of inspection reports, with header accuracy of 95% and detail accuracy of 85%. Then deliver the PACP exchange database, the videos with the required file names, and the PDF reports. Ontario gives 10 business days, and non-compliant submissions are corrected at the contractor's expense.
- 10
Bill the accepted footage
Payment is per linear foot actually cleaned and verified through television inspection, usually measured center of manhole to center of manhole. Reverse setups and re-televising are normally not paid again. Prince Albert pays 75% on completion and holds 25% until the deliverables are accepted, so the invoice follows acceptance, not the day the truck left.
What to record
The fields every sewer camera and hydro jetting job should capture
Each pipe segment
- Owner's pipe segment reference, upstream manhole ID and downstream manhole ID
- Street and nearest address, diameter, material, shape, mapped length, sanitary, storm or combined
- Owner spec that applies: PACP version, speed limit, stop time, counter tolerance, video format, file name pattern
- Status: To clean, Cleaned, Televised, Abandoned (reverse needed), QC passed, Delivered, Accepted, Rejected
- Light or heavy cleaning classification, passes made, root cut or deposit cut used
- Access notes: manhole in traffic lane, buried or not found, easement, hydrant used
Each inspection run
- Operator name and NASSCO certificate number, expiry date, PACP version certified
- Date, time, weather, direction of survey (upstream or downstream), pre-cleaning yes/no
- Counter check that day: measured distance versus counter, pass or fail
- Each observation: distance, PACP code, clock position from and to, continuous defect start and end, grade, still photo
- Lateral taps found, with distance and clock position; feet of each lateral televised where the spec asks (Wauwatosa: at least 30 ft)
- Total footage surveyed versus mapped length, abandonment reason and reverse setup result
- Video file name, exchange database export and PDF report reference
Cleaning, safety and disposal
- Truck, pump flow and pressure used, nozzle type, hose in the pipe, water source and hydrant meter reading
- Confined space entry permit if anyone entered: oxygen, LEL, H2S and CO readings with times, attendant, retrieval gear
- Traffic control layout used and any lane closure permit number
- Resident notices delivered, addresses on the blow-back list, blow-back or backup reports received
- Debris load: estimated cubic yards, disposal site, date, weigh ticket number and weight
- Damage or incident notes: stuck nozzle or camera, broken tap, sewer overflow, time the owner was told
Private lateral job
- Property address, parcel number, owner or agent, reason: sale, remodel permit, backup, city notice
- Cleanout location and type, lateral length, material, connection to the main confirmed
- Gas cross bore check done before any cutting tool: gas utility called yes/no, ticket number
- Findings with footage: roots, offset joint, belly, break; repair or replacement recommended
- Verification test type and result (water level or air pressure), witnessing inspector, certificate number and expiry
Rules and standards
The rules that shape the work, with their sources
| Rule | What it means on the job |
|---|---|
| NASSCO certification: 3 years, no grace period | PACP, LACP and MACP certification is valid for three years from issue. NASSCO no longer offers a one-year grace period: recertification must be completed before expiry, and a lapsed operator has to attend the initial class again. Reminder emails start six months before expiry. As of January 2024 the online recertification was $375 and the two-day trainer-led PACP initial class $925. source: NASSCO Policy 14, PACP/LACP/MACP Recertification (January 2024) |
| PACP Version 8 is the version being taught | NASSCO now trains only on Version 8. Version 7 certifications stay valid until they expire, and Versions 6 and earlier are being retired. Version 8 clarifies coding definitions, separates defects in new pipe from existing pipe, updates condition grades and adds code sets for pressure pipe, stormwater and perforated pipe. Owner specs lag: Wauwatosa's still asks for PACP 7.0 and San Francisco's for Version 6 or greater. source: NASSCO, PACP Version 8 information sheet (January 2024) |
| Four code families, three programs | PACP codes observations in four families: Structural, Operation and Maintenance, Construction and Miscellaneous. LACP applies the same codes to laterals, except that the only tap code used is Tap Break-In. MACP applies them to manhole components. The combined class runs 24 hours (PACP 16, LACP 3, MACP 5) and the open-book exam needs 85% to pass, with one retake. source: NASSCO, PACP/LACP/MACP 8.0 syllabus, 3-day class |
| Grades 1 to 5 no longer mean years to failure | Before Version 6 (2010), Grade 5 meant the pipe had failed or would likely fail within 5 years and Grade 4 that it would probably fail in 5 to 10 years. NASSCO withdrew that: remaining useful life is not defined for any PACP grade, because owners were planning renewals by querying Grade 4 and 5 observations without wider context. A report that promises a failure date from a grade is quoting withdrawn guidance. source: NASSCO Tech Tips, Edition 59 (June 2020): PACP condition grades and remaining useful life |
| Quick Rating and Pipe Rating Index | Each observation's grade is either structural or O&M. The PACP Quick Rating reports the peak severity grade seen in the pipe, and the Pipe Rating Index reports the average severity grade. Both are reported separately for structural, O&M and overall. source: NASSCO Tech Tip, PACP Quick Rating and Pipe Rating Index |
| Exchange database: Access is giving way to SQLite | With Version 8, NASSCO moved the PACP, LACP and MACP exchange database from Microsoft Access to SQLite. Owner specs written earlier still name Access: Wauwatosa asks for a NASSCO-PACP Certified Access Database. Check which file the owner's asset system can import before the first delivery. source: NASSCO, PACP Version 8 Exchange Database moves from Microsoft Access to SQLite |
| Corpus Christi 027611: speed, counter, rejection | The camera moves at no more than 30 ft per minute and must have pan and tilt. The footage counter is accurate to plus or minus 1% of actual length. Too high a water level or a submerged camera is grounds for rejection, and distortion, poor lighting or a dirty lens means repeating the work at no cost to the City. For new pipe an inclinometer is required and the belly tolerance is 5% or less. source: City of Corpus Christi TX, Section 027611, Cleaning and Televised Inspection of Conduits |
| Toronto TS 409: 5 seconds, 0.5%, a reversal for every abandonment | The operator must stop and view each defect or service connection clearly for at least five seconds. The counter must be within 0.5% of an above-ground steel tape measurement. Abandonment categories run from loose debris and high water level to manhole inaccessible and asset not found, and each abandonment needs a reversal. source: City of Toronto TS 409, CCTV inspection of sewers (September 2019) |
| Ontario OPSS.PROV 409: speed by diameter and weekly operator checks | Camera speed is 0.10 m/s for pipe up to 200 mm, 0.15 m/s from over 200 to 310 mm and 0.20 m/s above that. At least 80% of the pipe height must be visible. QC is verification of at least 10% of reports and two accuracy checks per operator per week; an operator who fails twice is barred from coding. Deliverables are due within 10 business days. source: Ontario OPSS.PROV 409, Closed-Circuit Television Inspection of Pipelines (June 2024 file) |
| Regina 2997: 20% water level and neighbors of a failed inspection | The maximum water level during inspection is 20% of the pipe. Video is MPEG-4 at 720 x 480, named PipeID_StartStructureID_Datetime.mp4. When an inspection fails QC (header 95%, data 85%), the five inspections done immediately before and after it are checked too. source: City of Regina SK, Section 2997, Sewer Cleaning and CCTV Inspection (April 2017) |
| San Francisco PUC: 1080p and one asset per video | Speed may not exceed 0.5 ft per second, and the operator stops, pans and zooms around all joints and lateral connections. Video is at least 1920 x 1080. Data is delivered in the NASSCO exchange database format so the City can import it whatever software the contractor used. Final CCTV of new work happens only after backfill, compaction and paving. source: San Francisco PUC, CCTV inspection specifications (December 2022) |
| NASSCO cleaning guideline: light versus heavy, and what is not paid | Light cleaning removes settled deposits up to 25% of pipe diameter in pipes up to 12 in, 15% in 13 to 24 in and 10% in 25 to 30 in; more than that is heavy cleaning. Cleaning is paid per linear foot actually cleaned and verified by television inspection, with reported footage within 2 ft of the measured manhole-to-manhole distance. Debris disposal, bypass pumping and re-televising after a point repair are incidental and not paid separately. source: NASSCO Specification Guideline, Sewer Cleaning |
| Columbus SS-4: 95%, three passes, minimum jetter | Cleaning must restore at least 95% of internal pipe height in sewers up to 60 in and 98% in larger ones. A line still needing work after three passes is heavy cleaning. The jet unit carries at least 600 ft of 3/4 in hose and nozzles of at least 30 gpm at 1,000 to 1,500 psi. All material is removed at the downstream manhole and hauled off at the end of each workday. source: City of Columbus OH, SS-4, Sewer Cleaning |
| OSHA 1910.146: the air limits for a manhole entry | A hazardous atmosphere includes flammable gas above 10% of its lower flammable limit and oxygen below 19.5% or above 23.5%. Testing order is oxygen, then flammables, then toxics. Retrieval systems are required for entry unless they would increase the overall risk. source: OSHA 29 CFR 1910.146, Permit-required confined spaces |
| Hydrogen sulfide limits | Sewer gas is the toxic the monitor is there for. OSHA lists a general industry ceiling of 20 ppm for hydrogen sulfide, a construction 8-hour limit of 10 ppm, and NIOSH's immediately dangerous to life or health level of 100 ppm. source: OSHA, Hydrogen Sulfide: Hazards (exposure limits) |
| MUTCD Part 6: manhole work is short-term stationary or short duration | The MUTCD (2009 edition, Section 6G.02) defines short duration work as up to 1 hour at a location and short-term stationary as daytime work of more than 1 hour, and says most maintenance and utility operations are short-term stationary. Vehicles with high-intensity flashing lights may stand in for signs and channelizing devices on short duration work, but safety should not be compromised by using fewer devices. source: FHWA MUTCD 2009 edition, Part 6, Chapter 6G (work duration, utility operations) |
| OSHA 1926.1204(e): sewers cannot be isolated | On construction work, where a space cannot be isolated because it is part of a continuous system such as a sewer, the employer must continuously monitor entry conditions where entrants are working and provide an early-warning system for engulfment hazards coming from upstream. source: OSHA 29 CFR 1926.1204, Permit-required confined space program (construction) |
| Hydrant water: permit, meter and air gap | Fayetteville PWC requires every tank truck drawing from a hydrant to have an inspected air gap at least double the supply pipe diameter above the tank's overflow rim, never less than 1 in, with no quick disconnects. source: Fayetteville NC Public Works Commission, Air Gap for Tanker Trucks |
| Debris: decant to the sewer, solids to an approved site | Miami-Dade's UC-290 says debris may never be dumped into streets, ditches, storm drains or other sanitary sewers, but water decanted from the solids is returned to the sewer. Solids go straight to the County's Class I landfill only if at least 20% solids with no visible moisture. Improper disposal is charged at $500 per load, and disposal records show site, date, amount and a description. source: Miami-Dade Water and Sewer Department, specification UC-290 (sewer cleaning debris disposal) |
| Blow-backs: Ottawa's notice list and claims route | Ottawa explains that high pressure water creates air pockets in the sewer, and if the vent path is blocked the air can escape through a toilet or drain, on rare occasions with sewage. Properties with a past blow-back go on an advance notification list, get a hand delivered notice 24 to 48 hours ahead, and are cleaned at lowered pressure. Residents who hire a cleaner can claim reasonable documented costs from the City. source: City of Ottawa, Sewer cleaning (blow-backs, advance notification, claims) |
| EPA CMOM: no fixed frequency, but records are the program | EPA's CMOM guide sets no cleaning interval: a restaurant district may need cleaning every six months while new PVC may go five years. It expects records of date, time, location, cleaning method, cause of stoppage, crew, follow-up and weather, and suggests tracking stoppages per mile of sewer. Its checklist asks whether contractors take video before and after cleaning. source: US EPA, Guide for Evaluating CMOM Programs at Sanitary Sewer Collection Systems (EPA 305-B-05-002) |
| Consent decrees turn footage into a legal quota | Under the 2014 East Bay consent decree, Oakland must inspect by CCTV or an equally effective method no less than 10% of its sewer mains each fiscal year (at least 485,760 ft) and clean at least 971,520 ft a year from July 2018. After an overflow it must CCTV immediately downstream of the location. A contractor's weekly footage is evidence in that count. source: US v. EBMUD et al., consent decree (Case 3:09-cv-05684-RS, filed 8 Sept 2014) |
| EBMUD private sewer laterals: 20 years or 7 | In Alameda, Albany, Emeryville, Oakland, Piedmont and the Stege Sanitary District, a compliance certificate is needed when a property is sold, when building or remodeling exceeds $100,000, or when the water meter size changes. A fully replaced lateral earns a 20-year certificate, a repaired one 7 years. The witnessed test passes with no water level loss in a 5 ft standpipe after 5 minutes, or an air drop of no more than 1 psi in 5 minutes from at least 3.5 psi. source: EBMUD, Private Sewer Lateral Program: Guidelines for Contractors (August 2019) |
| Pittsburgh: dye test before a sale | Anyone selling property in Pittsburgh needs evidence of compliance with the dye testing ordinance: the test is done by a certified plumber or general contractor, the processing fee is $20 and the certificate lasts three years. source: Pittsburgh Water, Dye Testing (Evidence of Compliance) |
| Santa Barbara 14.46: CCTV lateral inspection tied to permits | Santa Barbara is not point of sale. A building permit for an addition over 400 sq ft of habitable space, or for two or more new plumbing fixtures, triggers a lateral inspection, as does an overflow. Nonresidential and common interest properties are inspected once every 10 years. The inspection must, at a minimum, use a closed-circuit television device. Laterals replaced within 20 years or inspected within 3 are exempt. source: Santa Barbara Municipal Code Chapter 14.46, Sewer Lateral Inspection Program |
| Gas cross bores: call before you clear | PG&E tells plumbers to assume every obstruction involves a cross bore, to clear without a cutting tool, to check the blades for yellow or orange plastic when the cable is withdrawn, and to watch for bubbles in the toilet. If a gas cross bore is found, PG&E covers the associated sewer line repair. source: PG&E, Sewer cleaning safety (cross bore instructions for plumbers) |
| Washington Gas: stop, call 811, say "cross bore" | If a cross bore is suspected, Washington Gas says to stop all work, not to try clearing the blockage with any mechanical cutting device, and to call 811 for an emergency ticket using the phrases Sewer Clearing or Cross Bore. It has documented about 47 cross bores system-wide, and warns gas can migrate into a building that has no gas service. source: Washington Gas, Call Before You Clear |
| Root foam is a pesticide application | Razorooter II is 37.3% diquat dibromide, mixed at 2 quarts per 100 gallons of water and foamed at 20 gallons of foam per gallon of solution; the label says 100 gallons treats 800 ft of 8 in pipe and tells the applicator to notify the wastewater agency before use. source: US EPA accepted label, Razorooter II (diquat dibromide), EPA Reg. No. 64898-8 |
| Florida Category 7C: Sewer Root Control applicators | Florida's applicator rule has a dedicated category, 7C Sewer Root Control, for people using or supervising restricted use pesticides to control or prevent root growth in sewer lines. It is valid for both commercial and public applicators. Other states set their own categories, so check before quoting foam work across a state line. source: Fla. Admin. Code R. 5E-9.021, applicator categories (7C Sewer Root Control) |
| CIPP lining: CCTV before, CCTV after, robotic cutter for taps | Corpus Christi's CIPP spec requires a pre-installation TV inspection video after cleaning and an acceptance TV inspection after lining. Service connections are reopened from inside with a camera and a robotic cutter to not less than 100% capacity, and cutters that use high pressure water are banned because they may damage the service. Two complete working cutter units must be on site before each insertion. source: City of Corpus Christi TX, Section 027614, Cured-in-Place Pipe (CIPP) |
| UK: MSCC5 and a 5-year certificate | In the UK the WRc Manual of Sewer Condition Classification is the standard; MSCC5 (2013) is the current edition and MSCC6 is in development. From 1 April 2024 MSCC5 certificates are required and all CCTV training certificates carry a 5-year expiry; the OS19X course is 5 days. source: Water UK IGN 4-00-04, Issue 1 (April 2026), CCTV survey training and MSCC5 |
| Australia: WSA 05-2020 | Australia codes inspections to WSA 05-2020, the Conduit Inspection Reporting Code of Australia, Version 4.1, a uniform coding system for defects and features seen when inspecting conduits and maintenance structures. source: WSA 05-2020 Conduit Inspection Reporting Code of Australia, Version 4.1 (ABLIS listing) |
Rules vary by state, council and contract. Checked 20 November 2026; confirm against the source for your area before relying on it.
Numbers
Jetter sizing, spec tolerances and published prices
Equipment rows are from manufacturer and NASSCO documents; spec rows are one owner each, so check your contract; price rows are real bid tabulations and one consumer survey, not a market average.
| Item | Number | Basis |
|---|---|---|
| Trailer jetter, low flow | 1/2 to 3/4 in hose; a 15 gpm machine uses 300 gal in 20 minutes | NASSCO Tech Tips, Aug 2016 |
| Truck jetter, high flow | 1 to 1 1/4 in hose; an 80 gpm machine uses 1,500 gal in 19 minutes | NASSCO Tech Tips, Aug 2016 |
| Pressure lost in the hose | 80 gpm at 2,500 psi through 500 ft of 1 in hose loses 870 psi: 1,630 psi at the nozzle | NASSCO Tech Tips, Aug 2016 |
| Hose ID by pipe size | 1/2 in: 4 to 6 in pipe, 8 to 20 gpm; 3/4 in: 4 to 8 in, 20 to 60 gpm; 1 in: 4 to 10 in, 30 to 70 gpm | Dultmeier chart E3262 |
| Combination truck | Up to 100 gpm at 2,000 psi; 1,000 to 1,500 gal water; 5 to 15 cu yd debris; up to 1,000 ft of hose | Vactor 2100i brochure |
| Rotating nozzle, 4 to 8 in pipe | 1,200 to 5,000 psi, 9 to 21 gpm, 300 to 500 rpm | StoneAge Warthog WS manual |
| Pressure ceilings by pipe | CIPP liner: never over 2,000 psi; plastic: 1,400 psi at the tool; fiberglass: 870 to 1,450 psi | Plumber magazine, Nov 2020, quoting Insituform, Enz and Amiblu guides |
| Camera speed | 30 ft/min (Corpus Christi, Wauwatosa, SFPUC); Ontario 0.10 to 0.20 m/s by diameter | Owner specs |
| Counter accuracy | 1% (Corpus Christi, Wauwatosa, Ontario); 0.5% (Toronto); 0.2% (Prince Albert) | Owner specs |
| Stop at a defect | At least 5 seconds (Toronto); 10 to 15 seconds (Prince Albert) | Owner specs |
| Hydrant meter, DC Water | $80 permit; $3,000 deposit for a 3 in meter with backflow preventer; $300 under 15 days, then $20 a day | DC Water fees |
| Lateral compliance certificate, EBMUD | $270 including one verification test (fee schedule effective 1 July 2020) | EBMUD PSL fees |
| Routine cleaning cycle | Oro Loma CA: about 50,000 ft a month to cover the system every 30 months; hot spots on 1, 3, 6 and 12 month lists | Oro Loma Sanitary District |
| Normal cleaning, 8 to 12 in | $0.62 to $3.00 per linear ft across seven bidders (engineer's estimate $1.00) | Ann Arbor ITB 4409 bid tab |
| Video inspection, 8 to 12 in | $0.85 to $4.50 per linear ft across seven bidders | Ann Arbor ITB 4409 bid tab |
| Heavy cleaning, 8 to 12 in | $1.50 to $6.00 per linear ft; extra heavy $142 to $350 per hour | Ann Arbor ITB 4409 bid tab |
| Residential hydro jetting | Most homeowners pay $350 to $600, average $475; camera inspection $275 to $1,800 | Angi, Oct 2026 |
source: NASSCO Tech Tips (August 2016), jetter flow, pressure and hose losssource: Dultmeier catalog page E3262, sewer jetter hose and nozzle selection chartsource: Vactor 2100i brochure (April 2025)source: StoneAge Warthog WS Classic manualsource: Plumber magazine (November 2020), Avoiding Damage: jetting pressure limits by pipe materialsource: City of Corpus Christi TX, Section 027611, Cleaning and Televised Inspection of Conduitssource: City of Wauwatosa WI, Section 614, Sewer Televisingsource: Ontario OPSS.PROV 409, Closed-Circuit Television Inspection of Pipelines (June 2024 file)source: City of Toronto TS 409, CCTV inspection of sewers (September 2019)source: City of Prince Albert SK, Section 02800, CCTV Sewer Inspectionsource: DC Water, fees (fire hydrant permit and meter rental)source: EBMUD, Private Sewer Lateral Program fees (effective 1 July 2020)source: City of Windsor ON, S-19, Cleaning of Gravity Sewers, Manholes and Catchbasins (January 2015)source: Oro Loma Sanitary District CA, sewer cleaning schedulessource: City of Ann Arbor MI, ITB 4409 detailed bid tabulation, Sanitary Sewer Cleaning and Televisingsource: Angi, How much does hydro jetting cost? (updated 23 Oct 2026)
Where it breaks
Where spreadsheets and generic software fall over
The job is one line in the schedule: "Elm St, clean and TV, 4,200 ft". Nobody can say which of the 19 segments were cleaned but not televised, which were abandoned at 60 ft and still need a reverse setup, and which the city has accepted.
Make the segment the unit of work, with its own status from To clean through Accepted, and bill only from segments at Accepted.
An operator's PACP card expired in March. He kept coding until the city's reviewer checked the certificate number in June, and three months of inspections were rejected for re-televising at the contractor's cost.
Hold each operator's certificate number, version and expiry, warn six months out the way NASSCO does, and block an expired operator from being assigned to a coded inspection.
Each city wants a different file name, video format and database, and the crew uses the one they remember. Regina's PipeID_StartStructureID_Datetime.mp4 gets delivered to an owner that wanted upstream and downstream manhole IDs, and the submission bounces.
Store the owner's spec on the contract (file name pattern, format, speed, stop time, tolerance, deliverable deadline) and show it on the crew's phone at every setup.
Invoiced footage comes from the map, inspected footage from the counter, and the two differ. NASSCO's guideline lets the owner reject payment when reports are more than 2 ft off the measured distance.
Record mapped length, counter length and the daily counter check per segment, and flag any segment outside the spec's tolerance before it goes on an invoice.
Debris loads are tipped and the weigh tickets stay in the cab. At closeout the owner asks for disposal documentation for every load and half are missing.
Log each load against the segments it came from with the site, date, ticket number and a photo of the ticket, and hold the closeout package until every load has one.
A drain tech runs a root cutter down a blocked lateral without asking about gas, or a resident's basement toilet blows back during main cleaning and the claim arrives a month later with no record of the pressure used or the notice given.
Put the cross bore questions in front of any cutting tool step, keep a blow-back address list with reduced pressure notes, and record notices delivered and pressure used on each segment.
Checklist
The sewer camera and hydro jetting operations checklist
Print it, or hand it to whoever runs the office side.
- Every operator's PACP, LACP and MACP certificate number, version and expiry on file, with renewal started six months out
- Owner spec summarized per contract: PACP version, speed, stop time, counter tolerance, water level limit, video format, file name pattern, deliverable deadline
- Segment list loaded with owner asset IDs, upstream and downstream manholes, diameter, material and mapped length
- Hydrant meter permit in hand, air gap or backflow device inspected, meter readings logged
- Traffic control layout chosen per manhole; lane closure permits where needed
- Resident notices delivered where required; blow-back addresses flagged for lower pressure
- Gas monitor calibrated and bump tested; entry permit, attendant and retrieval gear ready before any manhole entry
- Footage counter checked against a measured distance each day and the result recorded
- Debris removed at the downstream manhole, never passed to the next segment
- Every abandoned survey followed by a reverse setup, with comment and photo
- Urgent findings (overflow, blockage near 90%, collapse, suspected cross bore) reported to the owner the same day
- Weigh ticket or disposal record for every debris load
- QC review of coding before submission, at least the share the spec requires (10% in Ontario)
- Exchange database, videos and PDF reports delivered inside the deadline with the owner's file names
- Invoice built from accepted footage, with re-televising and reverse setups not billed twice
Software options
What software sewer camera inspection and hydro jetting companies actually use
Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.
WinCan VX
CCTV contractors and utilities that need coded inspections in many national standards
Inspection data capture and reporting software; WinCan says it has been in this market since 1990 and supports over 100 standards. WinCan VX 17.7 is on NASSCO's list of software certified for PACP Version 8. It is the inspection record, not a dispatch or billing system.
ITpipes (and PipeLogix Phoenix)
Municipal crews and contractors who want inspection software with AI-assisted coding
Inspection capture and review with an AI coding product (AiDetect, price on request) and export in the NASSCO exchange format. NASSCO lists ITpipes 2.0 as certified for Version 7 and PipeLogix Phoenix 1.2.8, listed under ITpipes OpCo, for Version 8.
CUES GraniteNet
Fleets running CUES camera trucks
Inspection and asset or task management software from the camera maker CUES, sold in Basic and Advanced editions with add-on modules. GraniteNet 6.x is NASSCO certified for PACP Version 8.
POSM
Contractors and cities inspecting sewer, storm and manholes with mixed camera brands
Pipeline inspection data management software. POSM 11 is NASSCO PACP Version 8 certified.
PipeTech
Contractors who want planning, capture, review and delivery in one inspection product
Field inspection software with a hub for planning and delivering projects; PipeTech 2.x is certified for PACP and LACP Version 8.
SewerAI
Utilities and contractors with a backlog of video to code
Cloud platform with AI defect coding. Pricing models are published without amounts: Pioneer is an annual seat-based subscription and AutoCode is usage-based. NASSCO lists SewerAI Pioneer as certified for Version 7, and notes that it does not currently certify automated defect recognition software.
General field service software (ServiceTitan, Jobber, Housecall Pro)
Drain cleaning and plumbing firms doing residential jetting and lateral inspections
Good at calls, dispatch, estimates and invoices for residential drain work. None appears on NASSCO's certified software list, so a firm that also takes municipal CCTV work still needs a PACP tool beside it, and segment status, per-foot billing and deliverable tracking would be custom fields or spreadsheets.
Published prices, compared:source: NASSCO, PACP certified software vendorssource: WinCan, sewer inspection softwaresource: ITpipes, pipe inspection softwaresource: CUES, GraniteNet softwaresource: POSM Softwaresource: PipeTech, pipeline inspection softwaresource: SewerAI, pricing models
Questions to ask any vendor
- Is the pipe segment (upstream manhole to downstream manhole) a record with its own status, or just a note on a job?
- Can each contract hold the owner's CCTV spec (speed, stop time, counter tolerance, file name pattern, deadline) and show it to the crew on site?
- Will it stop me assigning an operator whose NASSCO certificate has expired, and warn me six months before?
- How does it sit next to WinCan, ITpipes, GraniteNet or POSM: can I attach the exchange database, videos and PDF to each segment and see what has not been delivered?
- Can it invoice per linear foot from accepted segments only, with separate rates for light cleaning, heavy cleaning, root cutting and CCTV by diameter band?
- Can a private lateral job carry the test result, the witnessing inspector and the certificate expiry (7 or 20 years at EBMUD, 3 years in Pittsburgh)?
Bring one real sewer camera and hydro jetting job. We show it running in Fieldproxy.
Get DemoHow Fieldproxy is set up for this
Sewer camera and hydro jetting on Fieldproxy: built around how you already work
A Fieldproxy setup for a sewer CCTV and jetting contractor is built around the segment, not the job: every manhole-to-manhole run carries its owner's spec, its cleaning passes, its inspection run, its abandonment and reverse setup, its debris load and its accepted footage. The PACP coding stays in WinCan, ITpipes, GraniteNet or POSM. Fieldproxy runs everything around it: crews and certificates, water and traffic permits, confined space records, QC, deliverables, per-foot billing and the lateral certificates on the plumbing side.
Module 1
Contracts and owner spec sheets
Two cities ten miles apart want different speeds, file names and databases, and the spec decides whether you are paid.
- Record: Contract, linked to Owner (city, utility, district, general contractor); fields: PACP version required, max camera speed, stop time at defects, counter tolerance, water level limit, video format and resolution, file name pattern, exchange database type (Access or SQLite), deliverable deadline in business days, retainage (e.g. 25% until deliverables accepted)
- Rate card per contract: light cleaning, heavy cleaning, root cut, deposit cut, CCTV, each by diameter band and per linear foot; hourly extra heavy cleaning; items the spec makes incidental marked Not billable (reverse setup, re-televise, disposal)
- Spec summary card shown on the crew app at every setup, e.g. "30 ft/min, stop 5 s at each tap, counter within 0.5%"
- Emergency notification rules per owner: blockage at or above a set percent, overflow, collapse, with who to call
Module 2
Segment register
The owner accepts and pays by segment, so the segment has to be the thing with a status.
- Record: Segment, linked to Contract and Work order; fields: owner pipe reference, upstream and downstream manhole IDs, street, diameter, material, mapped length, sewer type
- Segment status: To clean, Cleaned, Televised, Abandoned, Reverse done, QC passed, Delivered, Accepted, Rejected (re-televise)
- Bulk import of the owner's segment list from a spreadsheet or GIS export, matched on asset ID
- Map view by status so a supervisor can see the street that still has two abandoned runs
- Block: a segment cannot move to Televised without a counter check logged that day and a certified operator on the run
Module 3
Crews, trucks and certificates
A CCTV van without a current PACP operator, or a jet truck without an inspected air gap, cannot do billable work.
- Record: Operator certificate with program (PACP, LACP, MACP), NASSCO number, version, issue and expiry date; UK operators hold MSCC5 with a 5-year expiry instead
- Other credentials per person: confined space entrant, attendant or supervisor training, traffic control, pesticide applicator category for root foam (e.g. Florida 7C)
- Record: Truck with type (combination jet/vac, CCTV van, trailer jetter, lateral launch), pump gpm and psi, hose size and length, water tank and debris body size, air gap inspection date
- Blocks: expired PACP operator cannot be assigned to a coded inspection; LACP required for lateral launch work; truck with a lapsed air gap inspection cannot be routed to a hydrant-fill job
Module 4
Pre-work: water, traffic and notices
The day is lost if the hydrant permit, lane closure or resident notice was not sorted the week before.
- Record: Hydrant permit with utility, meter serial, deposit paid, rental start, daily meter readings and return date, so deposits such as DC Water's $3,000 come back
- Traffic control plan per manhole: layout reference, lane closure permit number, flagger needed yes/no
- Resident notice task per street with delivered date; blow-back address list carried on the segment with a reduced pressure note
- A segment cannot be scheduled until its water source, traffic plan and required notices are marked ready
Module 5
Crew app: cleaning
Light versus heavy cleaning is a price difference, and the proof is how many passes it took and what came out.
- Works offline in the cab and syncs later; opens on the day's segments in upstream order
- Per segment: nozzle used, pump pressure and flow, passes made, step lengths, root cut or deposit cut, debris type (grit, grease, roots, rock), estimated volume
- Heavy cleaning request: after the spec's pass limit (e.g. three passes), the foreman submits photos or a clip for the owner's inspector to approve before more time is spent
- Material check prompts a pressure ceiling for lined or plastic pipe (e.g. 2,000 psi for CIPP)
- Confined space entry form when anyone enters: readings in OSHA order with times, attendant, retrieval gear, permit closed
Module 6
Crew app: inspection run log
The PACP file holds the defects. What gets lost is everything around it: the counter check, the abandonment, the reverse setup and which file belongs to which segment.
- Daily counter check: measured distance, counter reading, percent error against the contract tolerance, pass or fail
- Per run: operator, direction, start and end footage, weather, pre-cleaned yes/no, water level acceptable yes/no
- Abandonment: reason from the owner's list (debris, high water, obstruction, manhole inaccessible, asset not found), footage reached, photo; creates a Reverse setup task automatically
- Urgent finding button: collapse, overflow, blockage over the owner's threshold, suspected cross bore; notifies the office with the owner's contact
- File slots: video, exchange database export and PDF report attached to the segment, with the expected file name generated from the contract's pattern
Module 7
QC and deliverables tracker
Specs set an accuracy bar (95% header, 85% detail) and a deadline, and a failed inspection can pull its neighbors into review.
- Record: QC review, sampled at the contract's rate (e.g. 10% of reports, two per operator per week); fields: header score, detail score, reviewer, pass or fail
- A failed review reopens the segment and adds the inspections before and after it to the review queue where the spec says so
- Record: Submission, grouping segments delivered together; fields: due date from the contract's business-day deadline, sent date, owner response, rejected segments with reason
- Rejected segments return to the schedule as Re-televise, flagged Not billable
Module 8
Debris loads and disposal
Owners ask for proof of legal disposal per load, and some fine per load when it is missing.
- Record: Load, linked to Truck and the segments it came from; fields: disposal site, date, weigh ticket number, weight or cubic yards, ticket photo, decant location
- Dewatering note where the site sets a solids threshold (e.g. Miami-Dade's 20% solids)
- Closeout check: every cleaned segment maps to a load, every load has a ticket
Module 9
Per-foot billing and pay applications
Billing is footage times a rate by diameter and cleaning class, minus everything the spec says is incidental.
- Invoice lines built from Accepted segments: counter footage where the spec pays actual length, center-to-center mapped length where it pays that
- Footage check: flags segments where counter and mapped length differ by more than the tolerance (e.g. 2 ft) before invoicing
- Retainage held until the Submission is accepted; progress billing per month or per pay application
- Quantities against bid items so the office sees heavy cleaning footage used versus the allowance
- Sync to QuickBooks or Xero
Module 10
Lateral inspections, certificates and repair quotes
The residential side sells an inspection today and a lining or replacement next week, with a city certificate at the end.
- Record: Lateral inspection, linked to Property; fields: reason (sale, permit, backup, city notice), cleanout, length, material, findings with footage and stills, video link for the homeowner or agent
- Cross bore step before any cutter: gas service nearby, trenchless gas work known, utility called, ticket number; a cutter cannot be logged until it is answered
- Record: Compliance certificate with program (e.g. EBMUD, Pittsburgh dye test), test type and result, witnessing inspector, fee paid, certificate number and expiry (7 or 20 years, or 3 years)
- Quote for spot repair, lining or replacement from the findings, with pre-lining and post-lining CCTV as line items
- Report PDF from your own template for the buyer, seller and agent
The AI agents, set up for sewer camera inspection and hydro jetting companies
| Agent | When | What it does | What you get |
|---|---|---|---|
| Document intelligence agent | A city emails a work order, task order or segment list as a PDF or spreadsheet | Reads each line's asset ID, upstream and downstream manholes, diameter, length and the work asked for (clean, televise, root cut) and matches it to the contract | One Segment per line under a new Work order at To clean, with lines it could not match listed for the office to check |
| Watcher agent | An operator's NASSCO certificate reaches six months from expiry, a Submission is 3 business days from its deadline, a segment sits at Abandoned for more than e.g. 5 days, or a counter check fails | Reads certificates, contract deadlines and segment statuses and separates what blocks billing from what is only late | A daily list for the operations manager: who to book on recertification, which segments need a reverse setup, which deliverables are due, and which run to hold because the counter was out of tolerance |
| Dispatch agent | Next week's segments are released to the board | Matches segments to crews by certificate (PACP for mains, LACP for laterals), truck type and pump size against pipe diameter, hydrant permit area and distance, and keeps the cleaning truck one segment ahead of the camera | Draft daily runs per truck in upstream order, and a list of segments with no ready water source, traffic plan or certified operator |
| Vision agent | A driver photographs a landfill or plant weigh ticket, or a hydrant meter | Reads the ticket number, date, site and weight, or the meter serial and reading | The Load or Hydrant permit record filled in, with a prompt to retake the photo if the ticket number cannot be read |
| Video agent | A drain tech records a clip at the cleanout after a residential lateral inspection and talks through what the camera found | Takes the footage marks, findings and recommendation from what was shown and said. It does not assign PACP codes: coded municipal work stays with a certified operator in the PACP software | The Lateral inspection record filled in with findings by footage and a draft homeowner report for the tech to review |
| Autopilot | A lateral repair quote is unanswered after e.g. 4 days, a sale closing date is within 14 days with no certificate, or a pay application passes its terms | Drafts the follow-up with the inspection stills and the certificate deadline, or the payment chase with the accepted segment list attached | A draft email or text a person approves before it is sent |
Straight answers
Sewer camera and hydro jetting: FAQ
What software do sewer camera inspection and hydro jetting companies use?
For the inspection itself, NASSCO-certified software such as WinCan VX, ITpipes, CUES GraniteNet, POSM or PipeTech, because cities require a PACP exchange database with the video. For the business around it (crews, permits, disposal tickets, per-foot billing, lateral certificates), contractors use spreadsheets, a general tool such as ServiceTitan or Jobber on the residential side, or a configured platform such as Fieldproxy that tracks each segment next to the PACP software.
What is PACP certification and how long does it last?
PACP is NASSCO's Pipeline Assessment Certification Program, the standard way to code sewer main defects in North America. LACP covers laterals and MACP covers manholes. Certification lasts three years. NASSCO no longer gives a grace period, so an operator who lets it lapse must take the initial class again. The combined three-day class is 24 hours and the exam pass mark is 85%.
What do PACP grades 1 to 5 mean?
They rank the severity of each coded observation, from 1 (minor) to 5 (most significant), separately for structural and for operation and maintenance defects. Before 2010 the grades were tied to years to failure, for example Grade 5 as likely to fail within 5 years. NASSCO removed that, and remaining useful life is no longer defined for any grade.
How fast can a sewer camera travel during a CCTV inspection?
It depends on the owner's spec. Corpus Christi and Wauwatosa set a maximum of 30 ft per minute, and San Francisco PUC sets 0.5 ft per second, which is the same speed. Ontario's provincial spec varies it by diameter, from 0.10 m/s in pipe up to 200 mm to 0.20 m/s above 310 mm. The camera also has to stop at defects and laterals: at least 5 seconds in Toronto.
Why would a city reject a CCTV inspection?
Common grounds in real specs are a submerged camera or water level too high, a dirty or fogged lens, poor lighting, footage that does not match the measured length, wrong file names, header or coding accuracy below the bar (95% and 85% in Ontario, Toronto and Regina), and an operator without a current certificate. Rejected work is re-televised at the contractor's cost.
How is sewer cleaning and CCTV work paid?
Usually per linear foot, by diameter band, for footage actually cleaned and verified by television inspection. In Ann Arbor's ITB 4409 bid tab, seven bidders priced normal cleaning of 8 to 12 in sewer from $0.62 to $3.00 per foot and video inspection from $0.85 to $4.50 per foot. Disposal, reverse setups and re-televising are typically included in those prices, not paid on top.
What is the difference between light and heavy sewer cleaning?
NASSCO's specification guideline defines light cleaning as removing settled deposits up to 25% of the diameter in pipes up to 12 in, 15% in 13 to 24 in and 10% in 25 to 30 in. Anything beyond that is heavy cleaning. Columbus defines it by effort instead: a line still dirty after three passes of the jetter is heavy cleaning.
What pressure and flow does a sewer jetter use?
Trailer jetters for laterals run higher pressure and lower flow on 1/2 to 3/4 in hose, around 15 gpm. Truck units for mains run lower pressure and higher flow on 1 in hose: a Vactor 2100i can be configured up to 100 gpm at 2,000 psi, and Columbus requires at least 30 gpm at 1,000 to 1,500 psi. Hose length eats pressure: NASSCO's example loses 870 psi over 500 ft of 1 in hose.
Can hydro jetting damage a pipe?
Yes. A National Clay Pipe Institute test described in Plumber magazine showed punctures after 10 seconds at 60 gpm and 2,000 psi with the nozzle held still. Manufacturer guidance quoted there caps CIPP liners at 2,000 psi and plastic pipe at 1,400 psi at the tool. Jetting a main can also push air up a house lateral and cause a toilet blow-back, which is why Ottawa keeps an advance notice list.
What is a cross bore and what should a drain cleaner do about it?
A cross bore is a utility line, most dangerously a gas line, that was bored through a sewer lateral during trenchless installation. A root cutter can sever it. PG&E tells plumbers to assume every obstruction involves a cross bore, to call before clearing, to avoid cutting tools, and to check the blades for yellow or orange plastic. Washington Gas says to stop work and call 811 for an emergency ticket.
Do I need a sewer lateral inspection to sell a house?
In some places. In EBMUD's program area (including Oakland, Alameda and Emeryville) a sale requires a private sewer lateral compliance certificate, valid 20 years for a replaced lateral and 7 for a repaired one. Pittsburgh requires a dye test with a certificate valid three years. Santa Barbara ties its CCTV lateral inspection to building permits and a 10-year cycle for commercial property, not to sales.
How often do cities clean and televise their sewers?
EPA's CMOM guide sets no fixed interval. Oro Loma Sanitary District in California cleans about 50,000 ft a month to cover its system every 30 months, with trouble spots on 1, 3, 6 and 12 month lists. Under the East Bay consent decree, Oakland must inspect at least 10% of its mains a year.
Related guides
All sources on this page (59)
- source: City of Corpus Christi TX, Section 027611, Cleaning and Televised Inspection of Conduits
- source: NASSCO Policy 14, PACP/LACP/MACP Recertification (January 2024)
- source: City of Toronto TS 409, CCTV inspection of sewers (September 2019)
- source: City of Columbus OH, SS-4, Sewer Cleaning
- source: NASSCO, PACP Version 8 information sheet (January 2024)
- source: NASSCO, PACP/LACP/MACP 8.0 syllabus, 3-day class
- source: NASSCO Tech Tips, Edition 59 (June 2020): PACP condition grades and remaining useful life
- source: NASSCO Tech Tip, PACP Quick Rating and Pipe Rating Index
- source: NASSCO, PACP Version 8 Exchange Database moves from Microsoft Access to SQLite
- source: Ontario OPSS.PROV 409, Closed-Circuit Television Inspection of Pipelines (June 2024 file)
- source: City of Regina SK, Section 2997, Sewer Cleaning and CCTV Inspection (April 2017)
- source: San Francisco PUC, CCTV inspection specifications (December 2022)
- source: NASSCO Specification Guideline, Sewer Cleaning
- source: OSHA 29 CFR 1910.146, Permit-required confined spaces
- source: OSHA, Hydrogen Sulfide: Hazards (exposure limits)
- source: FHWA MUTCD 2009 edition, Part 6, Chapter 6G (work duration, utility operations)
- source: OSHA 29 CFR 1926.1204, Permit-required confined space program (construction)
- source: Fayetteville NC Public Works Commission, Air Gap for Tanker Trucks
- source: Miami-Dade Water and Sewer Department, specification UC-290 (sewer cleaning debris disposal)
- source: City of Ottawa, Sewer cleaning (blow-backs, advance notification, claims)
- source: US EPA, Guide for Evaluating CMOM Programs at Sanitary Sewer Collection Systems (EPA 305-B-05-002)
- source: US v. EBMUD et al., consent decree (Case 3:09-cv-05684-RS, filed 8 Sept 2014)
- source: EBMUD, Private Sewer Lateral Program: Guidelines for Contractors (August 2019)
- source: Pittsburgh Water, Dye Testing (Evidence of Compliance)
- source: Santa Barbara Municipal Code Chapter 14.46, Sewer Lateral Inspection Program
- source: PG&E, Sewer cleaning safety (cross bore instructions for plumbers)
- source: Washington Gas, Call Before You Clear
- source: US EPA accepted label, Razorooter II (diquat dibromide), EPA Reg. No. 64898-8
- source: Fla. Admin. Code R. 5E-9.021, applicator categories (7C Sewer Root Control)
- source: City of Corpus Christi TX, Section 027614, Cured-in-Place Pipe (CIPP)
- source: Water UK IGN 4-00-04, Issue 1 (April 2026), CCTV survey training and MSCC5
- source: WSA 05-2020 Conduit Inspection Reporting Code of Australia, Version 4.1 (ABLIS listing)
- source: NASSCO Tech Tips (August 2016), jetter flow, pressure and hose loss
- source: Dultmeier catalog page E3262, sewer jetter hose and nozzle selection chart
- source: Vactor 2100i brochure (April 2025)
- source: StoneAge Warthog WS Classic manual
- source: Plumber magazine (November 2020), Avoiding Damage: jetting pressure limits by pipe material
- source: City of Wauwatosa WI, Section 614, Sewer Televising
- source: City of Prince Albert SK, Section 02800, CCTV Sewer Inspection
- source: DC Water, fees (fire hydrant permit and meter rental)
- source: EBMUD, Private Sewer Lateral Program fees (effective 1 July 2020)
- source: City of Windsor ON, S-19, Cleaning of Gravity Sewers, Manholes and Catchbasins (January 2015)
- source: Oro Loma Sanitary District CA, sewer cleaning schedules
- source: City of Ann Arbor MI, ITB 4409 detailed bid tabulation, Sanitary Sewer Cleaning and Televising
- source: Angi, How much does hydro jetting cost? (updated 23 Oct 2026)
- source: NASSCO, PACP certified software vendors
- source: WinCan, sewer inspection software
- source: ITpipes, pipe inspection software
- source: CUES, GraniteNet software
- source: POSM Software
- source: PipeTech, pipeline inspection software
- source: SewerAI, pricing models
Run sewer camera inspection and hydro jetting work the way it actually runs.
A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.
Get a walkthroughOne price per company. Unlimited users.