Guide for stormwater BMP inspection and maintenance companies ยท checked 27 November 2026
Stormwater BMP inspection software built around the facility, the cleaning trigger and the county deadline
A stormwater maintenance company's real customer list is a list of facilities: a wet pond, a bioretention cell, an underground vault, a CDS unit in a parking lot. Each one has a recorded maintenance agreement, a local inspection cycle, a manufacturer cleaning trigger and a report form someone must file on time. This guide covers how the work runs from first inspection to certified closeout, the rules that shape it (Maryland's 3-year cycle, Wake County's June 30 deadline, Seattle's 60% catch basin rule), and what software these companies use.
See your own jobs set up this way
A 30-minute call. We show you stormwater BMP inspection and maintenance companies workflows running in Fieldproxy, built around how you work.
Short answer
Stormwater BMP inspection and maintenance companies need software that holds every facility with its type, as-built depths and recorded maintenance agreement, schedules inspections on the local cycle (every year by June 30 in Wake County NC, every 3 years in Maryland, at least every 5 years for Fairfax County's own inspections), records the measured sediment against the device's cleaning trigger, and closes the county's report with photos and a certification inside its deadline. MS4 platforms such as SwiftComply serve the city side; SWPPPTrack covers construction inspections; many contractors still run on spreadsheets and Survey123 forms. Fieldproxy is one option. Best for processes that don't fit a template, set up for you: each facility carries its jurisdiction's cycle and form, readings decide whether cleaning is due, and repairs stay open until the re-inspection passes.
Every 3 years
Maryland: stormwater systems inspected in the first year of operation, then at least once every 3 years
source: COMAR 26.17.02.11, Stormwater Management: Maintenance (Maryland)
June 30
Wake County NC: SCMs inspected every year by June 30 by the owner, HOA or site manager
75%
Contech CDS: clean when sediment fills 75% of the isolated sump
source: Contech, CDS Inspection and Maintenance Guide (New Jersey edition)
60%
Seattle: catch basin needs cleaning when sediment passes 60% of the depth to the lowest pipe invert
How a job runs
One stormwater BMP inspection job, from first call to paid
The order the work really happens in, and what has to be written down at each step so nothing is argued about later.
- 1
Take on the facility and read the paperwork
Get the recorded maintenance agreement, the as-built or record drawing and any manufacturer O&M manual. In Virginia the agreement is recorded in the land records, runs with the land and requires inspection and maintenance reports to the authority. Note which county or city the facility reports to, because neighbors use different cycles and forms.
- 2
Survey and tag every component
Walk the site and tag each part the form will ask about: inlet and outlet structures, forebay, emergency spillway, embankment, underdrain cleanouts, vault hatches, separator manholes, cartridge vaults. Record design depths from the as-built, because most cleaning triggers are a percentage of a design depth. Photograph the access route; North Carolina requires a maintenance access at least 10 feet wide to the nearest public right-of-way.
- 3
Schedule on the local cycle and the manufacturer interval
Set the inspection date from the jurisdiction (Wake County by June 30, Concord's 2026 window of March 15 to May 15) and the cleaning interval from the device. A StormFilter vault may need cartridges every year; Contech says replacement intervals across manufacturers run from more than once a year to up to 5 years. Book cartridges early: lead times can reach four weeks.
- 4
Inspect and measure
Measure sediment with a stadia rod or sludge judge, from the rim to the top of the pile and from the rim to the water surface, then compare with the as-built. Check vegetation or filter media, outlet clogging, embankment settlement, spillway rock, trash and oil. Seattle's tables flag pond sediment over 10% of designed depth, inlet pipes one third full, and embankments settled 4 inches.
- 5
Report findings and the needed work
Mark each component pass or fail with a photo and a plain description of the maintenance needed. Craven County NC wants a failed report filed within 48 hours, gives the owner 60 days to repair and certify, and treats an annual inspection 30 days past due as a violation.
- 6
Quote and get approval
Price the work by facility: vactor hours, cartridge count, sediment tons, mowing acres, rock or media replacement. Send it to the owner or HOA with the inspection photos and the county's deadline, because the deadline is what gets the quote approved.
- 7
Clean and repair
Clean separators and vaults in dry weather with no flow entering, usually with a vacuum truck from the surface. If anyone must enter a vault, OSHA's permit-required confined space rules apply: atmosphere testing, an entry permit and an attendant outside. Stop and call the authority if you find an oil or chemical spill.
- 8
Dispose and document
Haul solids and decant water as local rules require; Contech notes that separator sediment is often handled like catch basin sediment. Keep the disposal ticket and before and after photos of every cleaned component.
- 9
Re-inspect and certify
Re-inspect after the work and sign the certification. In Durham NC the post-construction inspection must be by a registered engineer, land surveyor or landscape architect, and the process repeats until no deficiencies remain. Fairfax County closes its notice only when the Maintenance Activity Report comes back with photos.
- 10
Invoice and set the next visit
Invoice against the contract or the approved quote, attach the certified report, and generate the next inspection from the completed one, not the scheduled one.
What to record
The fields every stormwater BMP inspection job should capture
Facility profile
- Facility type: wet pond, dry pond, stormwater wetland, bioretention cell, sand filter, permeable pavement, underground detention vault or pipe, hydrodynamic separator (CDS, Vortechs), media filter vault (StormFilter, Jellyfish), catch basin insert
- Jurisdiction, permit or plan number, recorded maintenance agreement book and page, local inspection cycle and due date, required report form and filing method
- As-built design depths: pond design depth, isolated sump height, vault diameter, ponding depth, media depth, cartridge count and height
- Manufacturer and model, O&M manual on file, cleaning trigger for that model (e.g. CDS 75% of sump; Vortechs 12 to 18 in below water surface)
- Access: hatch and manhole locations, lid weight, permit-required confined space yes/no, access route width, traffic control
- Owner, HOA or property manager, billing contact, who signs the certification
Each inspection
- Inspector, credential (PE, RLA, surveyor, NCSU SCM seminar certificate number, CESSWI), date and weather
- Per component: condition (pass, maintenance needed, repair needed), photo, description of work needed
- Sediment readings: rim to top of pile, rim to water surface, computed depth and percentage of the trigger
- Bioretention: ponding after storms, drawdown observed, mulch depth, plant coverage, underdrain cleanout caps
- Ponds: sediment in forebay and main pool, embankment settlement, spillway rock, outlet trash rack, woody vegetation on the dam
- Overall result: compliant, compliant with maintenance, non-compliant; date filed with the jurisdiction
Maintenance and closeout
- Work done per component, crew, truck, hours, confined space permit number if entered
- Cartridges replaced (count, type, lot), sediment removed (cubic yards or tons), decant water gallons
- Disposal facility and ticket number
- Before and after photos tied to the same component tags
- Re-inspection date and result, certification signed by, filed with the jurisdiction on
- Next inspection due and next cleaning forecast
Rules and standards
The rules that shape the work, with their sources
| Rule | What it means on the job |
|---|---|
| 40 CFR 122.34(b)(5): the MS4 must ensure long-term O&M | Small MS4 permits must require a post-construction program for new development and redevelopment that disturbs 1 acre or more, including smaller projects in a larger common plan. At a minimum the permittee must use an ordinance or other mechanism and ensure adequate long-term operation and maintenance of BMPs. This is where every local inspection program comes from; the federal rule sets no interval. source: 40 CFR 122.34, Permit requirements for regulated small MS4 permits (eCFR) |
| Maryland COMAR 26.17.02.11: first year, then every 3 years | Counties and municipalities must inspect all stormwater management systems in the first year of operation and then at least once every 3 years. Reports record the date, inspector, and the condition of vegetation or filter media, fences, spillways and valves, embankments, inlet and outlet structures, underground drainage, and sediment in storage and forebay areas. Owners get a deficiency notice with a repair time frame, followed by a re-inspection. source: COMAR 26.17.02.11, Stormwater Management: Maintenance (Maryland) |
| Virginia 9VAC25-875-535: recorded agreement that runs with the land | The operator submits a construction record drawing sealed by a Virginia registered professional. Long-term maintenance is set out in an instrument recorded in the local land records that runs with the land, grants access for maintenance and regulatory inspections, and requires inspection and maintenance reports to the VSMP or VESMP authority. Effective 1 July 2024. source: 9VAC25-875-535, Long-term maintenance of stormwater management facilities (Virginia) |
| Fairfax County VA: county inspection at least every 5 years, then a MAR with photos | The county inspects privately maintained facilities at least once every five years. Within 30 to 45 days it sends a Notice of Inspection by certified mail with a Condition Assessment Report; the owner closes it with a Maintenance Activity Report and photos for each item. The assessment does not include full confined space entry, and the county may ask the owner to pay for further investigation. source: Fairfax County VA, Private Stormwater Facility Maintenance |
| North Carolina 15A NCAC 02H .1050: access, dewatering, post-construction cleanout | Every SCM needs a way to draw down standing water for maintenance and inspection, must be cleaned out and returned to its approved design state after construction, and needs a maintenance access at least 10 feet wide, no steeper than 3:1, reaching the nearest public right-of-way. source: 15A NCAC 02H .1050, MDC for all stormwater control measures (North Carolina, Henderson County copy) |
| North Carolina 15A NCAC 02H .1052: bioretention media and drawdown | Maximum ponding for the design volume is 12 inches above the planting surface. The cell must be maintained so it drains at least one inch per hour at the planting surface. Triple shredded hardwood mulch 2 to 4 inches deep, at least one capped cleanout pipe on each underdrain line, and plantings designed for 75% coverage at five years. source: 15A NCAC 02H .1052, MDC for bioretention cells (North Carolina, Henderson County copy) |
| Wake County and Concord NC: owner-filed annual inspections with fixed windows | Wake County requires SCMs to be inspected every year by June 30 by the owner, HOA or site manager. Concord requires 2026 annual inspections between March 15 and May 15, filed only through its electronic map-based process; inspections on the old form are not accepted. source: City of Concord NC, SCM Inspections |
| Who may sign in North Carolina | Durham's ordinance (Sec. 14-160) requires the post-construction SCM inspection by a registered professional engineer, land surveyor or landscape architect, repeated until no deficiencies remain. Craven County's annual report form asks for the inspector's NCSU SCM Maintenance and Inspection Seminar certification number, wants a failed report within 48 hours, and allows 60 days to repair and certify. source: Craven County NC, SCM Annual Maintenance Inspection Report |
| Seattle Appendix G: maintenance standards by component | Catch basins need cleaning when sediment exceeds 60% of the depth from the bottom to the lowest pipe invert, or comes within 6 inches of it. Detention pipes and vaults when sediment exceeds 10% of the diameter for half the length, or 15% at any point. Wet ponds when sediment exceeds 10% of the designed pond depth. Inspection codes run annual, biannual, monthly, quarterly, wet season, plus extra checks after more than 1 inch of rain in 24 hours. source: City of Seattle, Stormwater Manual Appendix G, Operations and Maintenance Requirements (Directors' Rule 03-2026, July 2026) |
| Contech CDS: 75% of the isolated sump, dry weather | Measure the sediment pile against the as-built sump height and clean at 75% of capacity, or sooner if hydrocarbons and trash build up. Performance is not affected until 100% is exceeded. Clean with a vacuum truck in dry weather with no flow entering, and replace absorbent material when it is significantly discolored. source: Contech, CDS Inspection and Maintenance Guide (New Jersey edition) |
| Contech Vortechs: 12 to 18 inches below the water surface | Clean when sediment is within 12 to 18 inches of the dry-weather water surface: take one reading from the manhole rim to the top of the pile and one to the water surface, and clean if the difference is under 18 inches. Remove an oil or gasoline spill immediately. Anyone entering the unit follows confined space entry procedures. source: Contech, Vortechs Inspection and Maintenance Guide |
| OSHA 1910.146: vaults and separators as permit spaces | A permit-required confined space has, or could have, a hazardous atmosphere, an engulfment hazard, a trapping configuration, or another serious hazard. Entry needs the employer's permit space program, an entry permit and an attendant stationed outside who monitors the entrants. source: OSHA 29 CFR 1910.146, Permit-required confined spaces |
| EPA 2022 CGP: construction inspections and corrective action | Where EPA is the permitting authority, sites are inspected at least every 7 calendar days, or every 14 days and within 24 hours of a storm of 0.25 inches or more; sites discharging to sediment or nutrient-impaired or Tier 2, 2.5 or 3 waters need both. Routine fixes are due by the close of the next business day; a new or replacement control within 7 calendar days. Records are kept 3 years after coverage ends. Inspectors on projects covered from 17 Feb 2023 must pass EPA's course or hold a qualifying certification. source: US EPA, 2022 Construction General Permit, Parts 1 to 9 (as modified 2025) |
Rules vary by state, council and contract. Checked 27 November 2026; confirm against the source for your area before relying on it.
Numbers
Inspection cycles and cleaning triggers stormwater crews work to
Each row is one jurisdiction or one manufacturer. The recorded agreement or permit for a facility can be stricter, so put the rule on the facility, not in someone's head.
| Situation | Rule or number | Basis |
|---|---|---|
| Maryland county or municipal inspection | First year of operation, then at least every 3 years | COMAR 26.17.02.11 |
| Fairfax County VA private facilities | County inspects at least every 5 years; notice within 30 to 45 days | Fairfax County MSMD |
| Wake County NC | Owner inspection every year by June 30 | Wake County |
| Concord NC, 2026 | Annual inspection between March 15 and May 15, electronic only | City of Concord |
| Craven County NC failed inspection | Report within 48 h; repair and certify within 60 days; 30 days past due is a violation | Craven County form |
| Catch basin (Seattle) | Clean at 60% of sump depth or within 6 in of lowest invert | Seattle Appendix G, July 2026 |
| Detention vault or pipe (Seattle) | Clean at 10% of diameter over half the length, or 15% at any point | Seattle Appendix G |
| Wet pond (Seattle) | Clean when sediment exceeds 10% of designed pond depth | Seattle Appendix G |
| Contech CDS | Clean at 75% of isolated sump; e.g. CDS-6 top of pile 4.0 ft below water, 2.1 yd3 stored | Contech CDS guide, Table 1 |
| Contech CDS-10 / CDS-12 | Top of pile 7.0 ft / 8.5 ft below water at 75%; 5.8 / 8.4 yd3 | Contech CDS guide, Table 1 |
| Contech Vortechs | Clean when sediment is within 12 to 18 in of the dry-weather water surface | Contech Vortechs guide |
| Media filter cartridges | More than once a year to up to 5 years between maintenance; lead time up to 4 weeks | Contech |
| NC bioretention | 12 in max ponding; drain at least 1 in per hour at the planting surface | 15A NCAC 02H .1052 |
| EPA CGP construction site | Every 7 days, or 14 days plus within 24 h of 0.25 in of rain | 2022 CGP Part 4.2 |
source: COMAR 26.17.02.11, Stormwater Management: Maintenance (Maryland)source: Fairfax County VA, Private Stormwater Facility Maintenancesource: Wake County NC, Post-Construction Stormwatersource: City of Concord NC, SCM Inspectionssource: Craven County NC, SCM Annual Maintenance Inspection Reportsource: City of Seattle, Stormwater Manual Appendix G, Operations and Maintenance Requirements (Directors' Rule 03-2026, July 2026)source: Contech, CDS Inspection and Maintenance Guide (New Jersey edition)source: Contech, Vortechs Inspection and Maintenance Guidesource: Contech, Maintenance considerations for media-based stormwater filtration systemssource: 15A NCAC 02H .1052, MDC for bioretention cells (North Carolina, Henderson County copy)source: US EPA, 2022 Construction General Permit, Parts 1 to 9 (as modified 2025)
Where it breaks
Where spreadsheets and generic software fall over
The schedule says "annual" for every site. The Concord sites must be filed between March 15 and May 15, the Wake County ones by June 30, and the Maryland ones are on a 3-year county cycle, so the spring rush is missed for one county while crews inspect another early.
Put the jurisdiction's cycle, window and filing method on each facility, and show what is due by jurisdiction and by week.
Inspectors write "sediment heavy" instead of two rod readings. When the owner asks why a CDS unit needs a vactor clean-out, there is no record that the pile reached 75% of the sump.
Make the rim-to-pile and rim-to-water readings required, store the as-built sump height on the device, and compute the percentage against that model's trigger.
A failed inspection is emailed to the HOA and then nothing happens. Sixty days later the county's enforcement letter arrives, and the contractor gets blamed for not following up.
Open a repair item per failed component with the county's deadline, chase the approval, and keep it open until the re-inspection passes and the certification is filed.
Cartridges are ordered when the crew opens the vault. With lead times of up to four weeks, the vactor truck makes two trips and the owner pays mobilization twice.
Forecast cartridge replacements from the last change date and interval, and order before the job is scheduled.
Photos sit on a phone named IMG_4412. Fairfax wants each maintenance item tied to a photo; a county reviewer cannot tell which outlet structure was cleaned.
Tag every component on the facility and take before and after photos inside that component's record so the report builds itself.
Someone climbs into a vault because it was quicker. There is no permit, no gas reading and no attendant on record.
Flag permit-required spaces on the facility and block the job from closing without the entry permit, atmosphere readings and attendant name.
Checklist
The stormwater BMP inspection operations checklist
Print it, or hand it to whoever runs the office side.
- Every facility on file with type, jurisdiction, recorded agreement and as-built design depths
- Each jurisdiction's inspection cycle, filing window, form and who may sign recorded
- Manufacturer and model with its cleaning trigger and O&M manual attached
- Next inspection generated from the last completed inspection
- Inspector credentials current (PE, RLA, surveyor, NCSU SCM certificate, CESSWI) and matched to what each jurisdiction accepts
- Two sediment readings per sump or vault, compared with the as-built height
- Bioretention drawdown, ponding depth, mulch depth and plant coverage checked
- Pond forebay and pool sediment, embankment settlement, spillway rock and outlet rack checked
- Failed components photographed, described and turned into repair items with the county deadline
- Cartridge replacements forecast and ordered ahead of lead time
- Confined space permit, atmosphere readings and attendant logged for any entry
- Disposal ticket kept for every load of sediment and decant water
- Re-inspection done and certification filed with the jurisdiction
- Construction sites on the 7 or 14 day CGP cycle with corrective actions closed on time
Software options
What software stormwater BMP inspection and maintenance companies actually use
Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.
SwiftComply
MS4 permit holders: cities and counties running a stormwater program
Cloud stormwater platform listed as an Esri partner solution, with workflows, mapping and reporting for tracking assets and inspections. Built for the regulator side; contractors meet it when a city asks them to file through it.
SWPPPTrack
Construction SWPPP and erosion control inspectors, MS4s, DOTs, builders and consultants
Inspection apps for erosion, NPDES and MS4 compliance with issue tracking and action items. Strong on the construction phase; less about vactor crews, cartridge stock and quoting repairs.
ArcGIS Survey123 and Field Maps
Teams that already keep their facilities in GIS
Form-based inspections tied to mapped assets. Flexible for data collection, but scheduling, quotes, crews, disposal tickets and invoicing sit in other systems.
Jobber
Small landscape or maintenance firms adding pond and rain garden work
General field service software with recurring visits, checklists, photos, quotes and invoices. Not built for stormwater, so jurisdiction cycles, sediment triggers, certifications and county filings would be custom fields and manual steps.
Manufacturer maintenance networks
Owners of proprietary devices
Contech lists Certified Contech Maintenance Providers by state and product (CDS, Vortechs, StormFilter, Jellyfish, Filterra and others). Not software, but where much proprietary device work is routed, and the provider still needs its own records.
Published prices, compared:source: Esri Partner listing, SwiftComply stormwater platformsource: SWPPPTrack, inspection and compliance appssource: Contech, Stormwater Maintenance Services (Certified Maintenance Provider search)
Questions to ask any vendor
- Can each facility, not each customer, carry its own jurisdiction cycle, filing window, report form and who may sign?
- Will the app take two rod readings and compute the percentage against that device's as-built depth and manufacturer trigger?
- Can a failed component become a repair item with the county's deadline, a quote and a re-inspection, all linked?
- Can you print a report in the layout Fairfax, Craven County or Maryland expects, with photos tied to each component?
- Can cartridge replacements be forecast from the last change date so stock is ordered before the job?
- Will the job refuse to close on a confined space entry without the permit, gas readings and attendant?
Bring one real stormwater BMP inspection job. We show it running in Fieldproxy.
Get DemoHow Fieldproxy is set up for this
Stormwater BMP inspection on Fieldproxy: built around how you already work
A Fieldproxy setup for a stormwater BMP company is built around the facility and the jurisdiction, not the customer: every pond, cell, vault and separator carries its recorded agreement, as-built depths, local cycle, filing window and manufacturer trigger. Inspectors log rod readings and tagged photos on an offline app, failed components become repair items with the county's deadline, and the certified report and next inspection are created when the re-inspection passes.
Module 1
Facility register and jurisdiction rules
Two sites of one property manager can sit in counties with different cycles, forms and signers. The facility is the unit of work.
- Record: Facility, linked to Site, Owner or HOA and Property manager; fields: type (wet pond, dry pond, wetland, bioretention, sand filter, permeable pavement, vault, separator, media filter, insert), recorded agreement book and page, plan number, install date
- Record: Jurisdiction rule: cycle (e.g. 1 year, 3 years), filing window start and end, form template, filing method (portal, email, mail), accepted signers (PE, RLA, surveyor, NCSU SCM certificate), repair deadline in days, re-inspection required yes/no
- Record: Component tags per facility (forebay, riser, trash rack, spillway, embankment, underdrain cleanout, vault hatch, sump, cartridge bay) with design depth or count from the as-built
- Facility status: Active, Under construction, Converted (construction cleanout done), Abandoned, Removed
Module 2
Contracts and recurring inspection schedule
Inspections are due on a calendar the county sets, and cleaning on a device interval; both must run from the last completed visit.
- Record: Service agreement per owner with rate card (per inspection, per vactor hour, per cartridge, per cubic yard, per acre mowed), billing contact and term
- Next inspection = last completed inspection + jurisdiction cycle, pulled into the filing window where one exists (e.g. Concord March 15 to May 15)
- Next cleaning forecast per device from its last cleaning and trigger history
- Visit status: Due, Booked, Inspected, Report filed, Repairs open, Re-inspected, Certified, Closed
Module 3
Inspector app: the inspection
The rod readings, photos and component results are what the county and the owner will ask for, and ponds and vaults are often out of signal.
- Works offline; opens on the facility with its component tags, as-built depths and last readings
- Required per sump or vault: rim to top of pile, rim to water surface; app computes depth and percentage against that model's trigger (e.g. CDS 75%, Vortechs 18 in)
- Per component: pass, maintenance needed, repair needed, with a photo required on anything not passing
- Bioretention fields: ponding observed, drawdown, mulch depth, plant coverage; pond fields: forebay sediment, embankment settlement, spillway rock
- Overall result: Compliant, Compliant with maintenance, Non-compliant; inspector credential stamped from their profile
Module 4
County report builder
Each jurisdiction wants its own layout, and a late or incomplete report counts as no inspection.
- PDF templates per jurisdiction (e.g. Craven County annual report, Durham cover sheet plus one form per SCM, Fairfax Maintenance Activity Report)
- Photos placed against the component they belong to, captioned automatically
- Filing task per report with the jurisdiction's deadline (e.g. 48 hours for a failed Craven report) and Filed date and reference
- Block: a report cannot be marked Filed without the signer's credential matching the jurisdiction's accepted list
Module 5
Repairs, quotes and approvals
The money is in the repairs, and the county deadline is what gets them approved.
- Record: Repair item per failed component with photo, description, jurisdiction deadline and days left
- Quote built from the rate card: vactor hours, cartridges, sediment tons, rock or media, mowing, traffic control
- Quote status: Draft, Sent, Approved, Declined, Expired; declined items stay on the facility history for the next inspection
- Approval by the HOA or manager in the portal, with the inspection photos attached
Module 6
Crews, vactor trucks and confined space
A vault clean-out needs the right truck, a dry day and, if anyone goes in, a permit and an attendant.
- Record: Truck with tank capacity, hose reach and the disposal sites it may use; crew members with confined space entrant, attendant and supervisor training dates
- Block: a job on a facility flagged permit-required cannot close if entry = yes without permit number, atmosphere readings (O2, LEL, H2S, CO) and attendant name
- Weather hold: cleaning jobs on separators and vaults flagged dry weather only can be bumped in one click with the owner notified
- Disposal: ticket number, facility, tons or cubic yards and decant gallons per load
Module 7
Cartridge and media stock
Media filter cartridges can take weeks to arrive; ordering when the vault is open costs a second mobilization.
- Record: Cartridge type and height per vault, count installed, last change date, expected interval
- Forecast of replacements due in the next 90 days by cartridge type
- Stock: on hand, on order, exchange returns pending; job cannot be booked until cartridges are on hand
- Bioretention media, mulch and rock as stocked items with cost for margin by job
Module 8
Construction SWPPP inspections
Many BMP firms also inspect active sites, where the clock is 7 or 14 days and the next business day for fixes.
- Record: Construction site with permit (EPA CGP or state permit), frequency option (7 days, or 14 days plus 24 h after 0.25 in), impaired or Tier 2 water flag
- Rain trigger: a logged storm of 0.25 in or more creates an inspection due within 24 hours during working hours
- Corrective action log: routine fix due by close of next business day, new or replacement control within 7 days, SWPPP update within 7 days of finishing
- Records held at least 3 years after coverage ends
Module 9
Owner portal and management reporting
Property managers with dozens of facilities want to see what is due, what failed and what it will cost without calling.
- Portal: every facility, last inspection, open repairs with deadlines, quotes awaiting approval, certified reports to download
- Dashboard: facilities due by jurisdiction and month, reports late to file, repairs past deadline, revenue by inspection versus repair
- Invoice sync to QuickBooks or Xero with the certified report attached
The AI agents, set up for stormwater BMP inspection and maintenance companies
| Agent | When | What it does | What you get |
|---|---|---|---|
| Watcher agent | A facility enters its jurisdiction's filing window without a booked inspection, a reading passes the device's trigger, or a repair item reaches 7 days before the county deadline | Reads the jurisdiction rule, the last three readings and the repair status, and separates late inspections from devices filling faster than their interval | A due-and-late list by jurisdiction for the office, and a recommended shorter cleaning interval on the device with the readings attached |
| Vision agent | An inspector photographs a stadia rod in a sump, a cartridge vault, or a disposal ticket | Reads the rod depth, counts visible cartridges against the vault record, and reads the ticket number and tons from the receipt | The reading, cartridge count or disposal fields filled on the job, and a prompt if the count does not match the as-built |
| Document intelligence agent | An owner forwards a recorded maintenance agreement, an as-built drawing or a county notice of inspection PDF | Reads the facility type, design depths, agreement reference and any deficiency deadlines, and matches them to the right facility | The facility filled with depths and agreement details, and repair items created against the notice's deadline |
| Voice agent | An inspector walking a pond dictates what they see component by component | Turns the notes into component results (pass, maintenance, repair) and work descriptions | The inspection form filled per component, ready for photos and signature |
| Autopilot | A repair quote sits unapproved for 7 days with a county deadline approaching, or an invoice passes its terms | Drafts the follow-up with the failed components, photos and the days left before enforcement, or the payment chase with the certified report | A draft email a person approves before it is sent |
| Scheduler agent | First Monday of each month | Collects facilities due next month by jurisdiction, cartridge replacements due in 90 days, and repairs past deadline | A monthly briefing emailed to operations and sales |
Straight answers
Stormwater BMP inspection: FAQ
What software do stormwater BMP inspection and maintenance companies use?
Many run on spreadsheets plus Survey123 forms or a construction inspection app such as SWPPPTrack, while the cities they report to use MS4 platforms such as SwiftComply. Small firms sometimes use general field service tools like Jobber. Fieldproxy is one option, set up around each facility's jurisdiction cycle, cleaning trigger and county report.
How often do stormwater BMPs have to be inspected?
It depends on the state and the locality, not on federal law. Maryland inspects in the first year and then at least every 3 years. Fairfax County inspects private facilities at least every 5 years. Wake County NC requires owners to inspect every year by June 30, and Concord NC set a 2026 window of March 15 to May 15.
When does a hydrodynamic separator need cleaning?
Follow the manufacturer's trigger for the model. Contech says to clean a CDS unit when sediment fills 75% of the isolated sump, and a Vortechs unit when sediment is within 12 to 18 inches of the dry-weather water surface. Clean sooner after an oil spill.
How do you measure sediment in a vault or separator?
Lower a stadia rod or sludge judge carefully to the top of the sediment pile and read from the manhole rim, then read from the rim to the water surface. Compare the pile height with the sump or vault height on the as-built drawing.
When does a catch basin need cleaning?
Seattle's 2026 standards say when sediment exceeds 60% of the depth from the bottom of the basin to the invert of the lowest pipe, or is within 6 inches of that invert, or when trash exceeds 1 cubic foot.
Who can sign an SCM inspection in North Carolina?
It varies by locality. Durham requires the post-construction inspection by a registered engineer, land surveyor or landscape architect. Craven County's annual form records the inspector's NCSU SCM Maintenance and Inspection Seminar certification number. Check the local ordinance before sending an inspector.
Is entering a stormwater vault a permit-required confined space?
Often, yes. OSHA 1910.146 covers spaces with a possible hazardous atmosphere, engulfment or trapping hazard. Entry needs a permit space program, an entry permit and an attendant outside. Contech's guides say to follow confined space procedures if anyone enters a unit.
How fast must a bioretention cell drain?
North Carolina's rule says the cell must be maintained to drain at least one inch per hour at the planting surface, with ponding for the design volume no deeper than 12 inches.
How often are construction sites inspected under EPA's CGP?
At least every 7 calendar days, or every 14 days and within 24 hours of a 0.25 inch storm. Sites discharging to impaired or Tier 2, 2.5 or 3 waters need weekly inspections and storm inspections. Most states run their own construction permit with their own schedule.
What does a CESSWI certification cost?
EnviroCert lists an application fee of $370 and an 8 hour review course at $385 when it sponsors the course, with the review manual sold separately ($75 electronic, $175 hard copy).
Related guides
All sources on this page (31)
- source: COMAR 26.17.02.11, Stormwater Management: Maintenance (Maryland)
- source: Wake County NC, Post-Construction Stormwater
- source: Contech, CDS Inspection and Maintenance Guide (New Jersey edition)
- source: City of Seattle, Stormwater Manual Appendix G, Operations and Maintenance Requirements (Directors' Rule 03-2026, July 2026)
- source: 40 CFR 122.34, Permit requirements for regulated small MS4 permits (eCFR)
- source: 9VAC25-875-535, Long-term maintenance of stormwater management facilities (Virginia)
- source: Fairfax County VA, Private Stormwater Facility Maintenance
- source: 15A NCAC 02H .1050, MDC for all stormwater control measures (North Carolina, Henderson County copy)
- source: 15A NCAC 02H .1052, MDC for bioretention cells (North Carolina, Henderson County copy)
- source: City of Concord NC, SCM Inspections
- source: Craven County NC, SCM Annual Maintenance Inspection Report
- source: Contech, Vortechs Inspection and Maintenance Guide
- source: OSHA 29 CFR 1910.146, Permit-required confined spaces
- source: US EPA, 2022 Construction General Permit, Parts 1 to 9 (as modified 2025)
- source: Contech, Maintenance considerations for media-based stormwater filtration systems
- source: Esri Partner listing, SwiftComply stormwater platform
- source: SWPPPTrack, inspection and compliance apps
- source: Contech, Stormwater Maintenance Services (Certified Maintenance Provider search)
Run stormwater BMP inspection and maintenance work the way it actually runs.
A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.
Get a walkthroughOne price per company. Unlimited users.