Guide for stormwater BMP inspection and maintenance companies ยท checked 27 November 2026

Stormwater BMP inspection software built around the facility, the cleaning trigger and the county deadline

A stormwater maintenance company's real customer list is a list of facilities: a wet pond, a bioretention cell, an underground vault, a CDS unit in a parking lot. Each one has a recorded maintenance agreement, a local inspection cycle, a manufacturer cleaning trigger and a report form someone must file on time. This guide covers how the work runs from first inspection to certified closeout, the rules that shape it (Maryland's 3-year cycle, Wake County's June 30 deadline, Seattle's 60% catch basin rule), and what software these companies use.

See your own jobs set up this way

A 30-minute call. We show you stormwater BMP inspection and maintenance companies workflows running in Fieldproxy, built around how you work.

Book your demo

A video call with our team

Number of employees

Short answer

Stormwater BMP inspection and maintenance companies need software that holds every facility with its type, as-built depths and recorded maintenance agreement, schedules inspections on the local cycle (every year by June 30 in Wake County NC, every 3 years in Maryland, at least every 5 years for Fairfax County's own inspections), records the measured sediment against the device's cleaning trigger, and closes the county's report with photos and a certification inside its deadline. MS4 platforms such as SwiftComply serve the city side; SWPPPTrack covers construction inspections; many contractors still run on spreadsheets and Survey123 forms. Fieldproxy is one option. Best for processes that don't fit a template, set up for you: each facility carries its jurisdiction's cycle and form, readings decide whether cleaning is due, and repairs stay open until the re-inspection passes.

Every 3 years

Maryland: stormwater systems inspected in the first year of operation, then at least once every 3 years

source: COMAR 26.17.02.11, Stormwater Management: Maintenance (Maryland)

June 30

Wake County NC: SCMs inspected every year by June 30 by the owner, HOA or site manager

source: Wake County NC, Post-Construction Stormwater

75%

Contech CDS: clean when sediment fills 75% of the isolated sump

source: Contech, CDS Inspection and Maintenance Guide (New Jersey edition)

60%

Seattle: catch basin needs cleaning when sediment passes 60% of the depth to the lowest pipe invert

source: City of Seattle, Stormwater Manual Appendix G, Operations and Maintenance Requirements (Directors' Rule 03-2026, July 2026)

How a job runs

One stormwater BMP inspection job, from first call to paid

The order the work really happens in, and what has to be written down at each step so nothing is argued about later.

  1. 1

    Take on the facility and read the paperwork

    Get the recorded maintenance agreement, the as-built or record drawing and any manufacturer O&M manual. In Virginia the agreement is recorded in the land records, runs with the land and requires inspection and maintenance reports to the authority. Note which county or city the facility reports to, because neighbors use different cycles and forms.

  2. 2

    Survey and tag every component

    Walk the site and tag each part the form will ask about: inlet and outlet structures, forebay, emergency spillway, embankment, underdrain cleanouts, vault hatches, separator manholes, cartridge vaults. Record design depths from the as-built, because most cleaning triggers are a percentage of a design depth. Photograph the access route; North Carolina requires a maintenance access at least 10 feet wide to the nearest public right-of-way.

  3. 3

    Schedule on the local cycle and the manufacturer interval

    Set the inspection date from the jurisdiction (Wake County by June 30, Concord's 2026 window of March 15 to May 15) and the cleaning interval from the device. A StormFilter vault may need cartridges every year; Contech says replacement intervals across manufacturers run from more than once a year to up to 5 years. Book cartridges early: lead times can reach four weeks.

  4. 4

    Inspect and measure

    Measure sediment with a stadia rod or sludge judge, from the rim to the top of the pile and from the rim to the water surface, then compare with the as-built. Check vegetation or filter media, outlet clogging, embankment settlement, spillway rock, trash and oil. Seattle's tables flag pond sediment over 10% of designed depth, inlet pipes one third full, and embankments settled 4 inches.

  5. 5

    Report findings and the needed work

    Mark each component pass or fail with a photo and a plain description of the maintenance needed. Craven County NC wants a failed report filed within 48 hours, gives the owner 60 days to repair and certify, and treats an annual inspection 30 days past due as a violation.

  6. 6

    Quote and get approval

    Price the work by facility: vactor hours, cartridge count, sediment tons, mowing acres, rock or media replacement. Send it to the owner or HOA with the inspection photos and the county's deadline, because the deadline is what gets the quote approved.

  7. 7

    Clean and repair

    Clean separators and vaults in dry weather with no flow entering, usually with a vacuum truck from the surface. If anyone must enter a vault, OSHA's permit-required confined space rules apply: atmosphere testing, an entry permit and an attendant outside. Stop and call the authority if you find an oil or chemical spill.

  8. 8

    Dispose and document

    Haul solids and decant water as local rules require; Contech notes that separator sediment is often handled like catch basin sediment. Keep the disposal ticket and before and after photos of every cleaned component.

  9. 9

    Re-inspect and certify

    Re-inspect after the work and sign the certification. In Durham NC the post-construction inspection must be by a registered engineer, land surveyor or landscape architect, and the process repeats until no deficiencies remain. Fairfax County closes its notice only when the Maintenance Activity Report comes back with photos.

  10. 10

    Invoice and set the next visit

    Invoice against the contract or the approved quote, attach the certified report, and generate the next inspection from the completed one, not the scheduled one.

What to record

The fields every stormwater BMP inspection job should capture

Facility profile

  • Facility type: wet pond, dry pond, stormwater wetland, bioretention cell, sand filter, permeable pavement, underground detention vault or pipe, hydrodynamic separator (CDS, Vortechs), media filter vault (StormFilter, Jellyfish), catch basin insert
  • Jurisdiction, permit or plan number, recorded maintenance agreement book and page, local inspection cycle and due date, required report form and filing method
  • As-built design depths: pond design depth, isolated sump height, vault diameter, ponding depth, media depth, cartridge count and height
  • Manufacturer and model, O&M manual on file, cleaning trigger for that model (e.g. CDS 75% of sump; Vortechs 12 to 18 in below water surface)
  • Access: hatch and manhole locations, lid weight, permit-required confined space yes/no, access route width, traffic control
  • Owner, HOA or property manager, billing contact, who signs the certification

Each inspection

  • Inspector, credential (PE, RLA, surveyor, NCSU SCM seminar certificate number, CESSWI), date and weather
  • Per component: condition (pass, maintenance needed, repair needed), photo, description of work needed
  • Sediment readings: rim to top of pile, rim to water surface, computed depth and percentage of the trigger
  • Bioretention: ponding after storms, drawdown observed, mulch depth, plant coverage, underdrain cleanout caps
  • Ponds: sediment in forebay and main pool, embankment settlement, spillway rock, outlet trash rack, woody vegetation on the dam
  • Overall result: compliant, compliant with maintenance, non-compliant; date filed with the jurisdiction

Maintenance and closeout

  • Work done per component, crew, truck, hours, confined space permit number if entered
  • Cartridges replaced (count, type, lot), sediment removed (cubic yards or tons), decant water gallons
  • Disposal facility and ticket number
  • Before and after photos tied to the same component tags
  • Re-inspection date and result, certification signed by, filed with the jurisdiction on
  • Next inspection due and next cleaning forecast

Rules and standards

The rules that shape the work, with their sources

RuleWhat it means on the job
40 CFR 122.34(b)(5): the MS4 must ensure long-term O&MSmall MS4 permits must require a post-construction program for new development and redevelopment that disturbs 1 acre or more, including smaller projects in a larger common plan. At a minimum the permittee must use an ordinance or other mechanism and ensure adequate long-term operation and maintenance of BMPs. This is where every local inspection program comes from; the federal rule sets no interval. source: 40 CFR 122.34, Permit requirements for regulated small MS4 permits (eCFR)
Maryland COMAR 26.17.02.11: first year, then every 3 yearsCounties and municipalities must inspect all stormwater management systems in the first year of operation and then at least once every 3 years. Reports record the date, inspector, and the condition of vegetation or filter media, fences, spillways and valves, embankments, inlet and outlet structures, underground drainage, and sediment in storage and forebay areas. Owners get a deficiency notice with a repair time frame, followed by a re-inspection. source: COMAR 26.17.02.11, Stormwater Management: Maintenance (Maryland)
Virginia 9VAC25-875-535: recorded agreement that runs with the landThe operator submits a construction record drawing sealed by a Virginia registered professional. Long-term maintenance is set out in an instrument recorded in the local land records that runs with the land, grants access for maintenance and regulatory inspections, and requires inspection and maintenance reports to the VSMP or VESMP authority. Effective 1 July 2024. source: 9VAC25-875-535, Long-term maintenance of stormwater management facilities (Virginia)
Fairfax County VA: county inspection at least every 5 years, then a MAR with photosThe county inspects privately maintained facilities at least once every five years. Within 30 to 45 days it sends a Notice of Inspection by certified mail with a Condition Assessment Report; the owner closes it with a Maintenance Activity Report and photos for each item. The assessment does not include full confined space entry, and the county may ask the owner to pay for further investigation. source: Fairfax County VA, Private Stormwater Facility Maintenance
North Carolina 15A NCAC 02H .1050: access, dewatering, post-construction cleanoutEvery SCM needs a way to draw down standing water for maintenance and inspection, must be cleaned out and returned to its approved design state after construction, and needs a maintenance access at least 10 feet wide, no steeper than 3:1, reaching the nearest public right-of-way. source: 15A NCAC 02H .1050, MDC for all stormwater control measures (North Carolina, Henderson County copy)
North Carolina 15A NCAC 02H .1052: bioretention media and drawdownMaximum ponding for the design volume is 12 inches above the planting surface. The cell must be maintained so it drains at least one inch per hour at the planting surface. Triple shredded hardwood mulch 2 to 4 inches deep, at least one capped cleanout pipe on each underdrain line, and plantings designed for 75% coverage at five years. source: 15A NCAC 02H .1052, MDC for bioretention cells (North Carolina, Henderson County copy)
Wake County and Concord NC: owner-filed annual inspections with fixed windowsWake County requires SCMs to be inspected every year by June 30 by the owner, HOA or site manager. Concord requires 2026 annual inspections between March 15 and May 15, filed only through its electronic map-based process; inspections on the old form are not accepted. source: City of Concord NC, SCM Inspections
Who may sign in North CarolinaDurham's ordinance (Sec. 14-160) requires the post-construction SCM inspection by a registered professional engineer, land surveyor or landscape architect, repeated until no deficiencies remain. Craven County's annual report form asks for the inspector's NCSU SCM Maintenance and Inspection Seminar certification number, wants a failed report within 48 hours, and allows 60 days to repair and certify. source: Craven County NC, SCM Annual Maintenance Inspection Report
Seattle Appendix G: maintenance standards by componentCatch basins need cleaning when sediment exceeds 60% of the depth from the bottom to the lowest pipe invert, or comes within 6 inches of it. Detention pipes and vaults when sediment exceeds 10% of the diameter for half the length, or 15% at any point. Wet ponds when sediment exceeds 10% of the designed pond depth. Inspection codes run annual, biannual, monthly, quarterly, wet season, plus extra checks after more than 1 inch of rain in 24 hours. source: City of Seattle, Stormwater Manual Appendix G, Operations and Maintenance Requirements (Directors' Rule 03-2026, July 2026)
Contech CDS: 75% of the isolated sump, dry weatherMeasure the sediment pile against the as-built sump height and clean at 75% of capacity, or sooner if hydrocarbons and trash build up. Performance is not affected until 100% is exceeded. Clean with a vacuum truck in dry weather with no flow entering, and replace absorbent material when it is significantly discolored. source: Contech, CDS Inspection and Maintenance Guide (New Jersey edition)
Contech Vortechs: 12 to 18 inches below the water surfaceClean when sediment is within 12 to 18 inches of the dry-weather water surface: take one reading from the manhole rim to the top of the pile and one to the water surface, and clean if the difference is under 18 inches. Remove an oil or gasoline spill immediately. Anyone entering the unit follows confined space entry procedures. source: Contech, Vortechs Inspection and Maintenance Guide
OSHA 1910.146: vaults and separators as permit spacesA permit-required confined space has, or could have, a hazardous atmosphere, an engulfment hazard, a trapping configuration, or another serious hazard. Entry needs the employer's permit space program, an entry permit and an attendant stationed outside who monitors the entrants. source: OSHA 29 CFR 1910.146, Permit-required confined spaces
EPA 2022 CGP: construction inspections and corrective actionWhere EPA is the permitting authority, sites are inspected at least every 7 calendar days, or every 14 days and within 24 hours of a storm of 0.25 inches or more; sites discharging to sediment or nutrient-impaired or Tier 2, 2.5 or 3 waters need both. Routine fixes are due by the close of the next business day; a new or replacement control within 7 calendar days. Records are kept 3 years after coverage ends. Inspectors on projects covered from 17 Feb 2023 must pass EPA's course or hold a qualifying certification. source: US EPA, 2022 Construction General Permit, Parts 1 to 9 (as modified 2025)

Rules vary by state, council and contract. Checked 27 November 2026; confirm against the source for your area before relying on it.

Numbers

Inspection cycles and cleaning triggers stormwater crews work to

Each row is one jurisdiction or one manufacturer. The recorded agreement or permit for a facility can be stricter, so put the rule on the facility, not in someone's head.

SituationRule or numberBasis
Maryland county or municipal inspectionFirst year of operation, then at least every 3 yearsCOMAR 26.17.02.11
Fairfax County VA private facilitiesCounty inspects at least every 5 years; notice within 30 to 45 daysFairfax County MSMD
Wake County NCOwner inspection every year by June 30Wake County
Concord NC, 2026Annual inspection between March 15 and May 15, electronic onlyCity of Concord
Craven County NC failed inspectionReport within 48 h; repair and certify within 60 days; 30 days past due is a violationCraven County form
Catch basin (Seattle)Clean at 60% of sump depth or within 6 in of lowest invertSeattle Appendix G, July 2026
Detention vault or pipe (Seattle)Clean at 10% of diameter over half the length, or 15% at any pointSeattle Appendix G
Wet pond (Seattle)Clean when sediment exceeds 10% of designed pond depthSeattle Appendix G
Contech CDSClean at 75% of isolated sump; e.g. CDS-6 top of pile 4.0 ft below water, 2.1 yd3 storedContech CDS guide, Table 1
Contech CDS-10 / CDS-12Top of pile 7.0 ft / 8.5 ft below water at 75%; 5.8 / 8.4 yd3Contech CDS guide, Table 1
Contech VortechsClean when sediment is within 12 to 18 in of the dry-weather water surfaceContech Vortechs guide
Media filter cartridgesMore than once a year to up to 5 years between maintenance; lead time up to 4 weeksContech
NC bioretention12 in max ponding; drain at least 1 in per hour at the planting surface15A NCAC 02H .1052
EPA CGP construction siteEvery 7 days, or 14 days plus within 24 h of 0.25 in of rain2022 CGP Part 4.2

source: COMAR 26.17.02.11, Stormwater Management: Maintenance (Maryland)source: Fairfax County VA, Private Stormwater Facility Maintenancesource: Wake County NC, Post-Construction Stormwatersource: City of Concord NC, SCM Inspectionssource: Craven County NC, SCM Annual Maintenance Inspection Reportsource: City of Seattle, Stormwater Manual Appendix G, Operations and Maintenance Requirements (Directors' Rule 03-2026, July 2026)source: Contech, CDS Inspection and Maintenance Guide (New Jersey edition)source: Contech, Vortechs Inspection and Maintenance Guidesource: Contech, Maintenance considerations for media-based stormwater filtration systemssource: 15A NCAC 02H .1052, MDC for bioretention cells (North Carolina, Henderson County copy)source: US EPA, 2022 Construction General Permit, Parts 1 to 9 (as modified 2025)

Where it breaks

Where spreadsheets and generic software fall over

The schedule says "annual" for every site. The Concord sites must be filed between March 15 and May 15, the Wake County ones by June 30, and the Maryland ones are on a 3-year county cycle, so the spring rush is missed for one county while crews inspect another early.

Put the jurisdiction's cycle, window and filing method on each facility, and show what is due by jurisdiction and by week.

Inspectors write "sediment heavy" instead of two rod readings. When the owner asks why a CDS unit needs a vactor clean-out, there is no record that the pile reached 75% of the sump.

Make the rim-to-pile and rim-to-water readings required, store the as-built sump height on the device, and compute the percentage against that model's trigger.

A failed inspection is emailed to the HOA and then nothing happens. Sixty days later the county's enforcement letter arrives, and the contractor gets blamed for not following up.

Open a repair item per failed component with the county's deadline, chase the approval, and keep it open until the re-inspection passes and the certification is filed.

Cartridges are ordered when the crew opens the vault. With lead times of up to four weeks, the vactor truck makes two trips and the owner pays mobilization twice.

Forecast cartridge replacements from the last change date and interval, and order before the job is scheduled.

Photos sit on a phone named IMG_4412. Fairfax wants each maintenance item tied to a photo; a county reviewer cannot tell which outlet structure was cleaned.

Tag every component on the facility and take before and after photos inside that component's record so the report builds itself.

Someone climbs into a vault because it was quicker. There is no permit, no gas reading and no attendant on record.

Flag permit-required spaces on the facility and block the job from closing without the entry permit, atmosphere readings and attendant name.

Checklist

The stormwater BMP inspection operations checklist

Print it, or hand it to whoever runs the office side.

  • Every facility on file with type, jurisdiction, recorded agreement and as-built design depths
  • Each jurisdiction's inspection cycle, filing window, form and who may sign recorded
  • Manufacturer and model with its cleaning trigger and O&M manual attached
  • Next inspection generated from the last completed inspection
  • Inspector credentials current (PE, RLA, surveyor, NCSU SCM certificate, CESSWI) and matched to what each jurisdiction accepts
  • Two sediment readings per sump or vault, compared with the as-built height
  • Bioretention drawdown, ponding depth, mulch depth and plant coverage checked
  • Pond forebay and pool sediment, embankment settlement, spillway rock and outlet rack checked
  • Failed components photographed, described and turned into repair items with the county deadline
  • Cartridge replacements forecast and ordered ahead of lead time
  • Confined space permit, atmosphere readings and attendant logged for any entry
  • Disposal ticket kept for every load of sediment and decant water
  • Re-inspection done and certification filed with the jurisdiction
  • Construction sites on the 7 or 14 day CGP cycle with corrective actions closed on time

Software options

What software stormwater BMP inspection and maintenance companies actually use

Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.

SwiftComply

MS4 permit holders: cities and counties running a stormwater program

Cloud stormwater platform listed as an Esri partner solution, with workflows, mapping and reporting for tracking assets and inspections. Built for the regulator side; contractors meet it when a city asks them to file through it.

source: SwiftComply

SWPPPTrack

Construction SWPPP and erosion control inspectors, MS4s, DOTs, builders and consultants

Inspection apps for erosion, NPDES and MS4 compliance with issue tracking and action items. Strong on the construction phase; less about vactor crews, cartridge stock and quoting repairs.

source: SWPPPTrack

ArcGIS Survey123 and Field Maps

Teams that already keep their facilities in GIS

Form-based inspections tied to mapped assets. Flexible for data collection, but scheduling, quotes, crews, disposal tickets and invoicing sit in other systems.

source: ArcGIS Survey123 and Field Maps

Jobber

Small landscape or maintenance firms adding pond and rain garden work

General field service software with recurring visits, checklists, photos, quotes and invoices. Not built for stormwater, so jurisdiction cycles, sediment triggers, certifications and county filings would be custom fields and manual steps.

source: Jobber

Manufacturer maintenance networks

Owners of proprietary devices

Contech lists Certified Contech Maintenance Providers by state and product (CDS, Vortechs, StormFilter, Jellyfish, Filterra and others). Not software, but where much proprietary device work is routed, and the provider still needs its own records.

source: Manufacturer maintenance networks

Published prices, compared:source: Esri Partner listing, SwiftComply stormwater platformsource: SWPPPTrack, inspection and compliance appssource: Contech, Stormwater Maintenance Services (Certified Maintenance Provider search)

Questions to ask any vendor

  • Can each facility, not each customer, carry its own jurisdiction cycle, filing window, report form and who may sign?
  • Will the app take two rod readings and compute the percentage against that device's as-built depth and manufacturer trigger?
  • Can a failed component become a repair item with the county's deadline, a quote and a re-inspection, all linked?
  • Can you print a report in the layout Fairfax, Craven County or Maryland expects, with photos tied to each component?
  • Can cartridge replacements be forecast from the last change date so stock is ordered before the job?
  • Will the job refuse to close on a confined space entry without the permit, gas readings and attendant?

Bring one real stormwater BMP inspection job. We show it running in Fieldproxy.

Get Demo

How Fieldproxy is set up for this

Stormwater BMP inspection on Fieldproxy: built around how you already work

A Fieldproxy setup for a stormwater BMP company is built around the facility and the jurisdiction, not the customer: every pond, cell, vault and separator carries its recorded agreement, as-built depths, local cycle, filing window and manufacturer trigger. Inspectors log rod readings and tagged photos on an offline app, failed components become repair items with the county's deadline, and the certified report and next inspection are created when the re-inspection passes.

Module 1

Facility register and jurisdiction rules

Two sites of one property manager can sit in counties with different cycles, forms and signers. The facility is the unit of work.

  • Record: Facility, linked to Site, Owner or HOA and Property manager; fields: type (wet pond, dry pond, wetland, bioretention, sand filter, permeable pavement, vault, separator, media filter, insert), recorded agreement book and page, plan number, install date
  • Record: Jurisdiction rule: cycle (e.g. 1 year, 3 years), filing window start and end, form template, filing method (portal, email, mail), accepted signers (PE, RLA, surveyor, NCSU SCM certificate), repair deadline in days, re-inspection required yes/no
  • Record: Component tags per facility (forebay, riser, trash rack, spillway, embankment, underdrain cleanout, vault hatch, sump, cartridge bay) with design depth or count from the as-built
  • Facility status: Active, Under construction, Converted (construction cleanout done), Abandoned, Removed
How this works

Module 2

Contracts and recurring inspection schedule

Inspections are due on a calendar the county sets, and cleaning on a device interval; both must run from the last completed visit.

  • Record: Service agreement per owner with rate card (per inspection, per vactor hour, per cartridge, per cubic yard, per acre mowed), billing contact and term
  • Next inspection = last completed inspection + jurisdiction cycle, pulled into the filing window where one exists (e.g. Concord March 15 to May 15)
  • Next cleaning forecast per device from its last cleaning and trigger history
  • Visit status: Due, Booked, Inspected, Report filed, Repairs open, Re-inspected, Certified, Closed
How this works

Module 3

Inspector app: the inspection

The rod readings, photos and component results are what the county and the owner will ask for, and ponds and vaults are often out of signal.

  • Works offline; opens on the facility with its component tags, as-built depths and last readings
  • Required per sump or vault: rim to top of pile, rim to water surface; app computes depth and percentage against that model's trigger (e.g. CDS 75%, Vortechs 18 in)
  • Per component: pass, maintenance needed, repair needed, with a photo required on anything not passing
  • Bioretention fields: ponding observed, drawdown, mulch depth, plant coverage; pond fields: forebay sediment, embankment settlement, spillway rock
  • Overall result: Compliant, Compliant with maintenance, Non-compliant; inspector credential stamped from their profile
How this works

Module 4

County report builder

Each jurisdiction wants its own layout, and a late or incomplete report counts as no inspection.

  • PDF templates per jurisdiction (e.g. Craven County annual report, Durham cover sheet plus one form per SCM, Fairfax Maintenance Activity Report)
  • Photos placed against the component they belong to, captioned automatically
  • Filing task per report with the jurisdiction's deadline (e.g. 48 hours for a failed Craven report) and Filed date and reference
  • Block: a report cannot be marked Filed without the signer's credential matching the jurisdiction's accepted list
How this works

Module 5

Repairs, quotes and approvals

The money is in the repairs, and the county deadline is what gets them approved.

  • Record: Repair item per failed component with photo, description, jurisdiction deadline and days left
  • Quote built from the rate card: vactor hours, cartridges, sediment tons, rock or media, mowing, traffic control
  • Quote status: Draft, Sent, Approved, Declined, Expired; declined items stay on the facility history for the next inspection
  • Approval by the HOA or manager in the portal, with the inspection photos attached
How this works

Module 6

Crews, vactor trucks and confined space

A vault clean-out needs the right truck, a dry day and, if anyone goes in, a permit and an attendant.

  • Record: Truck with tank capacity, hose reach and the disposal sites it may use; crew members with confined space entrant, attendant and supervisor training dates
  • Block: a job on a facility flagged permit-required cannot close if entry = yes without permit number, atmosphere readings (O2, LEL, H2S, CO) and attendant name
  • Weather hold: cleaning jobs on separators and vaults flagged dry weather only can be bumped in one click with the owner notified
  • Disposal: ticket number, facility, tons or cubic yards and decant gallons per load
How this works

Module 7

Cartridge and media stock

Media filter cartridges can take weeks to arrive; ordering when the vault is open costs a second mobilization.

  • Record: Cartridge type and height per vault, count installed, last change date, expected interval
  • Forecast of replacements due in the next 90 days by cartridge type
  • Stock: on hand, on order, exchange returns pending; job cannot be booked until cartridges are on hand
  • Bioretention media, mulch and rock as stocked items with cost for margin by job
How this works

Module 8

Construction SWPPP inspections

Many BMP firms also inspect active sites, where the clock is 7 or 14 days and the next business day for fixes.

  • Record: Construction site with permit (EPA CGP or state permit), frequency option (7 days, or 14 days plus 24 h after 0.25 in), impaired or Tier 2 water flag
  • Rain trigger: a logged storm of 0.25 in or more creates an inspection due within 24 hours during working hours
  • Corrective action log: routine fix due by close of next business day, new or replacement control within 7 days, SWPPP update within 7 days of finishing
  • Records held at least 3 years after coverage ends
How this works

Module 9

Owner portal and management reporting

Property managers with dozens of facilities want to see what is due, what failed and what it will cost without calling.

  • Portal: every facility, last inspection, open repairs with deadlines, quotes awaiting approval, certified reports to download
  • Dashboard: facilities due by jurisdiction and month, reports late to file, repairs past deadline, revenue by inspection versus repair
  • Invoice sync to QuickBooks or Xero with the certified report attached
How this works

The AI agents, set up for stormwater BMP inspection and maintenance companies

AgentWhenWhat it doesWhat you get
Watcher agentA facility enters its jurisdiction's filing window without a booked inspection, a reading passes the device's trigger, or a repair item reaches 7 days before the county deadlineReads the jurisdiction rule, the last three readings and the repair status, and separates late inspections from devices filling faster than their intervalA due-and-late list by jurisdiction for the office, and a recommended shorter cleaning interval on the device with the readings attached
Vision agentAn inspector photographs a stadia rod in a sump, a cartridge vault, or a disposal ticketReads the rod depth, counts visible cartridges against the vault record, and reads the ticket number and tons from the receiptThe reading, cartridge count or disposal fields filled on the job, and a prompt if the count does not match the as-built
Document intelligence agentAn owner forwards a recorded maintenance agreement, an as-built drawing or a county notice of inspection PDFReads the facility type, design depths, agreement reference and any deficiency deadlines, and matches them to the right facilityThe facility filled with depths and agreement details, and repair items created against the notice's deadline
Voice agentAn inspector walking a pond dictates what they see component by componentTurns the notes into component results (pass, maintenance, repair) and work descriptionsThe inspection form filled per component, ready for photos and signature
AutopilotA repair quote sits unapproved for 7 days with a county deadline approaching, or an invoice passes its termsDrafts the follow-up with the failed components, photos and the days left before enforcement, or the payment chase with the certified reportA draft email a person approves before it is sent
Scheduler agentFirst Monday of each monthCollects facilities due next month by jurisdiction, cartridge replacements due in 90 days, and repairs past deadlineA monthly briefing emailed to operations and sales

Straight answers

Stormwater BMP inspection: FAQ

What software do stormwater BMP inspection and maintenance companies use?

Many run on spreadsheets plus Survey123 forms or a construction inspection app such as SWPPPTrack, while the cities they report to use MS4 platforms such as SwiftComply. Small firms sometimes use general field service tools like Jobber. Fieldproxy is one option, set up around each facility's jurisdiction cycle, cleaning trigger and county report.

How often do stormwater BMPs have to be inspected?

It depends on the state and the locality, not on federal law. Maryland inspects in the first year and then at least every 3 years. Fairfax County inspects private facilities at least every 5 years. Wake County NC requires owners to inspect every year by June 30, and Concord NC set a 2026 window of March 15 to May 15.

When does a hydrodynamic separator need cleaning?

Follow the manufacturer's trigger for the model. Contech says to clean a CDS unit when sediment fills 75% of the isolated sump, and a Vortechs unit when sediment is within 12 to 18 inches of the dry-weather water surface. Clean sooner after an oil spill.

How do you measure sediment in a vault or separator?

Lower a stadia rod or sludge judge carefully to the top of the sediment pile and read from the manhole rim, then read from the rim to the water surface. Compare the pile height with the sump or vault height on the as-built drawing.

When does a catch basin need cleaning?

Seattle's 2026 standards say when sediment exceeds 60% of the depth from the bottom of the basin to the invert of the lowest pipe, or is within 6 inches of that invert, or when trash exceeds 1 cubic foot.

Who can sign an SCM inspection in North Carolina?

It varies by locality. Durham requires the post-construction inspection by a registered engineer, land surveyor or landscape architect. Craven County's annual form records the inspector's NCSU SCM Maintenance and Inspection Seminar certification number. Check the local ordinance before sending an inspector.

Is entering a stormwater vault a permit-required confined space?

Often, yes. OSHA 1910.146 covers spaces with a possible hazardous atmosphere, engulfment or trapping hazard. Entry needs a permit space program, an entry permit and an attendant outside. Contech's guides say to follow confined space procedures if anyone enters a unit.

How fast must a bioretention cell drain?

North Carolina's rule says the cell must be maintained to drain at least one inch per hour at the planting surface, with ponding for the design volume no deeper than 12 inches.

How often are construction sites inspected under EPA's CGP?

At least every 7 calendar days, or every 14 days and within 24 hours of a 0.25 inch storm. Sites discharging to impaired or Tier 2, 2.5 or 3 waters need weekly inspections and storm inspections. Most states run their own construction permit with their own schedule.

What does a CESSWI certification cost?

EnviroCert lists an application fee of $370 and an 8 hour review course at $385 when it sponsors the course, with the review manual sold separately ($75 electronic, $175 hard copy).

Related guides

All sources on this page (31)

Run stormwater BMP inspection and maintenance work the way it actually runs.

A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.

Get a walkthrough

One price per company. Unlimited users.