Guide for window film and tinting companies ยท checked 17 November 2026
Window film software that knows every pane, every roll and every tint law
A window film company sells square feet of film on glass it did not make. The money is in the takeoff (panes, sizes, which way they face, what the glass is) and the risk is in what happens later: a cracked insulated unit, a warranty claim with no lot number, a school that was told 8 mil film stops bullets, or a car that fails inspection. This guide covers how flat glass and automotive tint jobs run, what to record on each, the standards and state laws behind them, and how to set the work up.
See your own jobs set up this way
A 30-minute call. We show you window film and tinting companies workflows running in Fieldproxy, built around how you work.
Short answer
Window film and tinting companies mostly use Tint Wiz, which is built for tint shops and measures flat glass by room, item and pane, or automotive shop systems such as Urable, OrbisX and Shopmonkey, alongside pattern cutting software like Film and Vinyl Designs, XPEL DAP or Eastman Core. Jobber, Housecall Pro and ServiceTitan do not list window film as an industry. What matters is whether the tool holds a pane-level takeoff with glass type and orientation, checks film against glass before the quote, ties roll and lot numbers to the manufacturer warranty form, and prints the label or certificate your state requires on a car. Fieldproxy is one option. Best for processes that don't fit a template, set up for you: commercial dealers running security film programs across many buildings get takeoffs, film-to-glass checks, anchoring records and warranty packets on one job.
6 feet
Minimum distance for inspecting applied film under the IWFA guideline, at right angles, in daylight but not direct sun, ignoring a 2 inch band at the edge
30 to 140 days
Typical visual cure time by film thickness: up to 4 mil 30 days, 4 to 8 mil 60, 8 to 12 mil 90, over 12 to 17 mil 140
2,500 sq ft
Installation size above which LLumar's warranty form requires documented pre-approval from the manufacturer
source: LLumar (Eastman) architectural warranty and installation record, form L2097 (06/16)
$1,000
Maximum fine in Texas for a business that installs automotive film without the required label between film and glass
source: Texas Transportation Code 547.613, Restrictions on Windows (public.law copy)
How a job runs
One window film and tinting job, from first call to paid
The order the work really happens in, and what has to be written down at each step so nothing is argued about later.
- 1
Sort the enquiry: flat glass or vehicle, and what the film is for
Ask why they want film before you ask how many windows. Heat and glare is solar control film. Fading is UV. A break-in, a school safety rule or a blast specification is safety and security film with an attachment system. Privacy and branding is decorative or frosted film. A vehicle is a separate line of work with its own law. The purpose decides the film family, whether an attachment system is needed, and who has to approve the job.
- 2
Survey the glass, pane by pane
Walk the building by elevation and room. For each opening record the pane count, width and height in inches, glass type (clear, tinted, low-E, laminated, tempered, wired, textured), single pane or insulated unit, thickness, the frame and gasket material, which way it faces, any shading on part of the glass, and existing chips, cracks or old film. Photograph the spacer stamp on insulated units and any damage. A pane you did not record as chipped today is a pane you will be blamed for later.
- 3
Run the film-to-glass check before you quote
Film raises the temperature of the glass, which can stress the glass or the seals of an insulated unit. Manufacturers publish which glass conditions their breakage and seal warranty will not cover. A Solar Gard sample warranty excludes, among others, panes over 100 square feet, insulated units over 40 square feet, glass 3/8 inch or thicker, wired or textured glass, damaged glass, partial film coverage and exterior application. Flag every pane that hits an exclusion and either change the film, get written approval or leave the pane out.
- 4
Lay the panes out on the roll and price the job
Architectural film usually comes 36, 48 or 60 inches wide, with some safety and dry adhesive films at 72 inches, priced per 100 linear feet. The width you pick sets the waste: a 29 inch pane cut from a 36 inch roll leaves a 7 inch strip down the whole length. Group panes by width, choose the roll for each group, and price from the linear feet you will actually cut, plus lift or ladder access, furniture moves, removal of old film and after-hours labor.
- 5
Get approvals in before film is ordered
Large jobs and risky glass need paper first. LLumar's warranty form says all installations over 2,500 square feet require documented pre-approval from the manufacturer. Utility rebates often need an application before installation: Austin Energy says rebates are not paid retroactively. A landlord or property manager may need to approve the exterior appearance. Hold the job at a pre-approval status until each one is attached.
- 6
Prep, install and anchor
Protect floors and sills, scrape and clean the glass, apply the film wet and squeegee it out. The IWFA guideline expects edge gaps of roughly 1/32 to 1/16 inch, up to 1/8 inch on 7 mil safety film, and a splice gap of no more than 1/64 inch. Security film is either daylight applied, edge to edge, or anchored. A wet glaze attachment is structural silicone run around the perimeter, and the IWFA guide says the sealant must extend 3/16 inch or more onto both the glass and the frame. Record which method went on each opening.
- 7
Inspect the same day and explain the cure
The IWFA guideline allows inspection within one day of installation, from at least 6 feet. Water bubbles, distortion and haze during cure are not defects. Walk the job with the customer, note anything obtrusive, and hand over the care sheet: do not clean the film for 30 days, no ammonia cleaners, no abrasive pads. Write the expected cure date on the job from the film thickness, so a call about haze in week three gets the right answer.
- 8
Register the warranty with roll and lot numbers
The manufacturer warranty is only as good as the installation record. LLumar's form asks for the product number, lot or run number and square footage of each film, plus glass type, thickness, coatings and pane type, signed by the customer and the installer. Solar Gard's form asks for film type, area and roll number by elevation (north, south, east, west), and says it is not valid unless signed. Fill these from the job record, not from memory a year later.
- 9
For vehicles: check the law, cut, install, label
Look up the customer's state and vehicle type, meter the factory glass, and pick a film whose combined reading stays legal. Cut the pattern on a plotter or by hand, install, and meter again. Then do the paperwork the state asks of the installer: Florida wants a label on the inside left door jamb, Washington a sticker on the driver's door post with your business name and tax number, Texas a label between the film and the glass, and California a signed certificate the driver carries.
- 10
Invoice, file the rebate and hold the warranty packet
Invoice from the installed square feet. Send the rebate paperwork with the film's performance data and the square feet per orientation, since utilities often pay only for certain elevations. Keep one packet per job: takeoff, glass check, approvals, photos, the signed inspection, the warranty form and the leftover roll balance. That packet is what answers a cracked pane claim three winters later.
What to record
The fields every window film and tinting job should capture
Per opening (flat glass)
- Building, elevation (N, S, E, W), floor, room and opening ID that matches the marked-up plan or photo
- Pane count, width and height in inches, item type (window, door, transom, sidelight, skylight) and square feet
- Glass: clear, tinted, reflective, low-E and which surface if known, laminated, tempered, wired or textured; single pane or insulated unit; thickness
- Frame and gasket material and condition, partial shading, existing film, and chips, cracks or scratches with a photo taken before work
- Film product, thickness in mil, roll width used, side applied (interior or exterior) and attachment method (daylight, edge to edge, wet glaze, mechanical)
Per job
- Purpose of the film (solar, UV, safety, security or delayed entry, decorative) and any specification or rule it is meant to meet
- Film-to-glass check result per pane, exclusions hit, and the manufacturer's written approval where one was needed
- Roll and lot or run number for each film, linear feet cut and balance returned to stock
- Install date, installers, the expected cure date by film thickness, and the day-one inspection signed by the customer
- Warranty form reference, rebate application number and status, and the care sheet sent
Per vehicle
- Year, make, model, body type (sedan or multipurpose vehicle) and state of registration
- Factory glass meter reading per window before film, film product and shade per window, and combined reading after
- Windshield strip position, pattern used, and any medical exemption document seen and copied
- Label, sticker or certificate issued, where it was fixed, and the customer's signature on any shade darker than the shop advised
Rules and standards
The rules that shape the work, with their sources
| Rule | What it means on the job |
|---|---|
| IWFA visual inspection guideline | Applied film is viewed from the room side at right angles, in natural daylight but not direct sun, from not less than 6 feet, ignoring a 2 inch band around the edge. It is acceptable if dirt, hairs, gels, fingerprints, bubbles, scratches, creases and edge lift are unobtrusive from there. Inspection can be made within one day of installation, and water bubbles, distortion and haze during cure are not defects. There are no numeric defect counts. source: IWFA, Architectural Visual Inspection Guideline For Applied Window Film (1 Jan 2020), including Table 1 Typical Cure Times |
| Cure time by film thickness | IWFA Table 1 gives typical visual cure times: up to 4 mil 30 days, 4 to 8 mil 60 days, 8 to 12 mil 90 days, and over 12 up to 17 mil 140 days, longer or shorter with climate. Solar Gard's bulletin says drying may vary from a few days to 6 months. source: IWFA, Architectural Visual Inspection Guideline For Applied Window Film (1 Jan 2020), including Table 1 Typical Cure Times |
| Safety glazing impact categories (16 CFR 1201) | The CPSC standard has two impact levels: Category I at 150 foot-pounds (an 18 inch drop of a 100 pound shot bag, equal to ANSI Class B) and Category II at 400 foot-pounds (a 48 inch drop, Class A), tested to ANSI Z97.1-2015. source: Federal Register 81 FR 15427 (23 Mar 2016), CPSC Safety Standard for Architectural Glazing Materials: Category I 150 ft-lb, Category II 400 ft-lb, ANSI Z97.1-2015 test |
| Where Category II applies, and where film sits in the rule | Category II (400 foot-pounds) covers shower and bathtub doors and enclosures, sliding patio doors, and doors with any single lite over 9 square feet. Category I covers storm doors and doors with no lite over 9 square feet. Glass with a polymeric film bonded to it falls under the rule's definition of organic-coated glass, so a film sold as a safety upgrade needs a test report for the film and glass combination you are installing on. source: 16 CFR 1201.2 Definitions (Cornell LII): Category I and II products, organic-coated glass, permanent label |
| Why film can break glass | NFRC's consumer guide says applied film increases the glass temperature and may cause thermal stress on the glass or on insulated glazing seals. This is the reason behind every manufacturer's film-to-glass list. source: NFRC Efficient Windows guide, Window Film (thermal stress on glass and insulated glazing seals) |
| Glass breakage and seal failure warranties exclude listed glass | A Solar Gard sample warranty gives 5 years for thermal glass breakage and 3 years for insulated unit seal failure, capped at $500 per window with a $25 deductible, and lists excluded conditions: wired, textured or skylight glass, panes over 100 square feet, insulated units over 40 square feet, glass 3/8 inch or thicker, damaged glass, partial coverage, triple pane units, and frames with failed gaskets. Terms differ by manufacturer and year, so check the current form for the film you sell. source: Solar Gard (Saint-Gobain), Limited Residential/Commercial Warranty SK0375PAN, sample form: glass breakage and IG seal failure terms and excluded glass |
| Manufacturer pre-approval over 2,500 square feet | LLumar's architectural warranty form states that all installations over 2,500 square feet require documented pre-approval from the manufacturer. Its warranties are not transferable from one purchaser to another, for residential and commercial alike. source: LLumar (Eastman) architectural warranty and installation record, form L2097 (06/16) |
| NFRC label on film | NFRC independently certifies window film performance. The label reports U-factor, solar heat gain coefficient, visible transmittance and air leakage, with a CPD number to look the product up in the Certified Products Database. Without the label, the product is not certified. source: NFRC fact sheet hosted by IWFA, The Basics About Window Films (label contents, CPD number) |
| California Title 24 acceptance | California's Title 24 acceptance procedure for window film requires a temporary NFRC label on the film box, kept on site for the enforcement agency. source: Energy Code Ace, California Title 24 Part 6 Reference Appendix NA7.4.2 Window Films |
| Security film is not bullet resistant | IWFA's delayed entry guidance says safety and security film is not bullet-resistant and should not be represented as stopping bullets, and that attachment systems are strongly recommended for best performance. source: IWFA, Specifying Safety and Security Window Film for Delayed Entry (2024) |
| ASTM F3561 is a test for whole assemblies | Intertek describes ASTM F3561 as a test where a window or door assembly is first weakened with 5.56 NATO rounds, then struck by a forced entry impactor delivering 400 foot-pounds, giving a Level of 1 to 8. source: Intertek, ASTM F3561 forced entry resistance of fenestration systems after simulated active shooter attack |
| IWFA: do not specify F3561 for retrofit film | IWFA's ballistics statement says F3561 was not designed to evaluate retrofit building window film, and that using the standard in a bid specification or submittal is not appropriate and likely misleading. In ballistic glazing, film mainly acts as a spall shield. source: IWFA, Statements on Protection from and against Ballistics (ASTM F3561 and retrofit film) |
| Attachment methods and wet glaze bite | IWFA's safety and security guide lists three install methods: daylight, edge to edge, and anchored (mechanical or wet glazed). For wet glaze, the sealant must extend onto the glass and the framing system 3/16 inch or more. source: IWFA, Safety and Security Education Guide (2026): impact test, install methods, wet glaze bite |
| Blast ratings depend on the anchoring | Under GSA TS01-2003, glazing is rated from condition 1 (does not break) through 3a (fragments land within 3.3 feet) and 3b (within 10 feet) to 5 (catastrophic failure). Solar Gard's summary reports an 8 mil film reaching 3a with wet glaze or mechanical anchoring, and says mechanical systems are typically used above 8 psi. source: Solar Gard, GSA Blast Testing Summary (GSA TS01-2003 performance conditions and anchoring systems) |
| Film is not accepted everywhere for blast | The National Glass Association's blast paper says ASTM F1642 results are defined by five hazard ratings under ASTM F2912, and that fragment retention film and blast curtains may not be used for Department of Defense buildings required to comply with UFC 4-010-01. source: National Glass Association, Glass Technical Paper FB12-07 (2023), Blast Resistant Glazing |
| Safety film splices and drying | Solar Gard's bulletin says full cure is typically reached about 30 days after installation but drying may vary from a few days to 6 months. Splices on safety film should be horizontal and at the top of the window, with a 2 to 3 inch overlap recommended. source: Solar Gard Tech Bulletin PDF0250, Visual Inspection and Maintenance of Window Film (05/22) |
| Care after installation | Avery Dennison's maintenance sheet says not to clean the windows for 30 days, not to use harsh ammonia based cleaners, and that vapor cleaners are not recommended. source: Avery Dennison, Solar Films Maintenance Recommendations |
| Roll widths and how film is bought | Architectural film comes in standard rolls 36, 48 or 60 inches wide, with some dry adhesive and clear safety films at 72 inches, priced per 100 linear feet. A 29 inch pane cut from a 36 inch roll wastes a 7 inch strip along the whole length. source: Tint Depot tinting school, Installing Film on Architectural Glass (roll widths, 100 linear feet, waste) |
| IWFA accreditation is per person | IWFA offers four accreditation tests: Automotive Film Specialist, Safety and Security Film Specialist, Solar Control Specialist and Advanced Solar Control Specialist. They are awarded to individuals, not companies, need 80 percent to pass, and cost $50 per test for members and $100 for non-members. source: IWFA, Accreditation Tests (four individual accreditations, 80 percent pass mark, $50 members and $100 non-members per test) |
| Austin Energy rebate: apply before you install | Austin Energy lists $1.80 per square foot for film or solar shading with a solar heat gain coefficient of 0.37 or less on existing buildings, excludes glass facing north or northeast or more than 50 percent shaded in summer, and says applications must be submitted before installation because rebates are not paid retroactively. source: Austin Energy, commercial window film and solar shading rebate |
| Colorado Efficiency Works rebate: by orientation | $1.50 per square foot for professionally installed film with a solar heat gain coefficient of 0.35 or less, on clear single or double pane windows within 45 degrees of west, south or east, in buildings with air conditioning or electric heat. Incentives over $10,000 need pre-approval. source: Efficiency Works Business (Colorado), Envelope rebate incentives and conditions (revised Jan 2026) |
| Georgia Power rebate | $1 per square foot for film with a solar heat gain coefficient of 0.24 or less on south, east or west facing windows, and the film must cover the entire window. source: Georgia Power, Commercial Energy Efficiency Program, Building Envelope sheet (2026) |
| Texas schools: 19 TAC 103.1215 | Texas requires that ground-level windows near exterior doors, of a size and position that would permit entry if broken, cannot be easily broken, and gives forced entry-resistant film as an example. The same applies to glass exterior doors and to windows beside a door that would let someone reach in and open it. The rule names no ASTM standard and no film thickness. It was moved from 19 TAC 61.1031 to 103.1215 in 2026, so older bid documents cite the old number. source: Texas Education Agency, adopted new 19 TAC 103.1215 School Safety Requirements (2026) |
| Federal law reaches the shop, not just the car | 49 U.S.C. 30122 says a manufacturer, distributor, dealer, rental company or motor vehicle repair business may not knowingly make inoperative a device or element of design installed to meet a federal safety standard. source: 49 U.S. Code 30122, Making safety devices and elements inoperative (Cornell LII) |
| Federal Standard No. 205 | 49 CFR 571.205 requires vehicle glazing to conform to ANSI/SAE Z26.1-1996 and windshield shade bands to follow SAE J100. California's statute describes Standard 205's minimum light transmittance as 70 percent, which is why factory front glass leaves little room for film in 70 percent states. source: 49 CFR 571.205, Standard No. 205, Glazing materials (Cornell LII) |
| California: 70 percent combined and a signed certificate | Vehicle Code 26708(d) allows clear film on front side windows only if the film is at least 88 percent visible light transmittance and glass plus film meets 70 percent. The driver must carry a certificate signed by the installing company, naming the installer and the film manufacturer by full name and street address. Film that tears or bubbles must be removed or replaced. source: California Vehicle Code 26708 (FindLaw copy, current as of 1 Jan 2026) |
| Texas: 25 percent and a label under the film | Transportation Code 547.613 requires front side windows to pass 25 percent or more light and reflect 25 percent or less, measured with the glass, and limits windshield film to above the AS-1 line or the top five inches. Section 547.609 requires a label permanently installed between the film and the glass. A business that installs film without it commits a misdemeanor with a fine up to $1,000. source: Texas Transportation Code 547.613, Restrictions on Windows (public.law copy) |
| Florida: 28 percent front, a door jamb label and a 3 percent tolerance | Front side windows must pass at least 28 percent, windows behind the driver at least 15 percent, or 6 percent on multipurpose passenger vehicles. The installer must fix a nonremovable label to the inside left door jamb with the film's trade name and the installer's business name. Every percentage carries a tolerance of plus or minus 3 percent. Selling or installing film in violation is a second degree misdemeanor. source: Florida Statutes 316.2955, installer label and plus or minus 3 percent tolerance |
| New York: 70 percent, checked at inspection | New York DMV says 70 percent or more of outside light must pass through the windshield, front side windows and, on sedans and similar cars, the rear side windows. Tinted windows have been examined during the vehicle inspection since 1 January 2017. IWFA reported in June 2026 that the legislature passed a bill allowing 50 percent film and sent it to the governor, so check the current law before quoting a shade. source: New York DMV, Tinted Windows (70 percent rule, checked at inspection since 1 Jan 2017) |
| New York medical exemption: form MV-80W | The registrant completes page 1 and a New York licensed physician, physician assistant or nurse practitioner completes page 2, from an examination within 60 days of submission. Listed conditions include albinism, lupus erythematosus, porphyria, xeroderma pigmentosum and photophobia. source: New York DMV, form MV-80W Application for Tinted Window Exemption (6/24) |
| Illinois: the installer keeps the medical statement | 625 ILCS 5/12-503 bars anyone from installing prohibited material, with a first violation a petty offense fined $50 to $500. An installer fitting tint under the medical exemption must obtain the physician's statement first and keep it in permanent records. The statute allows a 5 percent variance when an officer meters the glass. source: Illinois 625 ILCS 5/12-503 (FindLaw copy): installer liability, penalties, medical statement kept by installer |
Rules vary by state, council and contract. Checked 17 November 2026; confirm against the source for your area before relying on it.
Numbers
Automotive tint: what six states ask of the car and of the shop
Percentages are visible light transmittance for film and glass together. This is a snapshot for sedans as read on 17 Nov 2026; laws change and multipurpose vehicles often differ, so check the statute or the IWFA interactive tool before quoting a shade.
| State | Front side windows | What the installer must do |
|---|---|---|
| California | 70% combined, using clear film of at least 88% | Give a signed certificate naming the installing company and the film manufacturer with full name and street address |
| Texas | 25% or more, reflectance 25% or less | Install a label between the film and the glass; a business that does not faces a fine up to $1,000 |
| Florida | 28% or more, reflectance 25% or less; plus or minus 3% tolerance | Fix a nonremovable label on the inside left door jamb with the film trade name and the business name |
| New York | 70% or more (a 50% bill passed the legislature in June 2026; check whether it is in force) | Nothing on the car, but tint is checked at the safety inspection, so an illegal shade comes back to the shop |
| Washington | 24% or more, reflectance 35% or less | Put a sticker on the driver's door post showing the business name and state tax identification number |
| Georgia | 32%, plus or minus 3%; reflectance 20% or less | No label in the section read; installing film that breaks the limit is itself a misdemeanor |
source: California Vehicle Code 26708 (FindLaw copy, current as of 1 Jan 2026)source: Texas Transportation Code 547.613, Restrictions on Windows (public.law copy)source: Texas Transportation Code 547.609, Required Label for Sunscreening Devices (public.law copy)source: Florida Statutes 316.2953, side windows forward of the driversource: Florida Statutes 316.2955, installer label and plus or minus 3 percent tolerancesource: New York DMV, Tinted Windows (70 percent rule, checked at inspection since 1 Jan 2017)source: Florida Statutes 316.2954, windows behind the driversource: Florida Statutes 316.2956, penalty for selling or installing sunscreening material in violationsource: Washington RCW 46.37.430, safety glazing and sunscreening (installer sticker on the driver's door post)source: Georgia O.C.G.A. 40-8-73.1 (FindLaw copy): 32 percent plus or minus 3 percentsource: IWFA, Interactive Tint Laws (state by state, by vehicle type)source: IWFA, New York Passes Legislature Making 50% VLT Legal, Updating Current Law (3 Jun 2026; bill sent to the governor)
Where it breaks
Where spreadsheets and generic software fall over
The takeoff is a total square footage, so nobody knows which pane was which
Record each opening with its elevation, room, pane count, size and glass type. Quotes, roll layouts, rebate forms (which pay by orientation) and warranty forms (which ask by elevation) all read from the same rows.
Film goes on glass the manufacturer excludes, and the cracked unit is yours
Make the film-to-glass check a required step with the manufacturer's exclusions as fields: pane area, unit area, thickness, glass type, damage, shading. A pane that fails can't be quoted without a written approval attached or a signed customer waiver.
Roll and lot numbers were never written down, so the warranty form is guesswork
Scan or type the roll and lot number when the film is cut for a job. The warranty form fills from the job, and a batch complaint from the manufacturer finds every site that roll went to.
Sales promised what security film cannot do
Put the purpose, the tested standard and the attachment method on the quote, with the plain sentence that film is not bullet resistant. Store the manufacturer's test report on the job so the claim in the proposal matches a document.
The customer calls about haze in week two and the office does not know if it is normal
Set a cure date on the job from the film thickness (30, 60, 90 or 140 days) and send the care sheet at close. Anyone answering the phone sees the install date, the film and the cure date.
The car leaves without the label, sticker or certificate the state requires
Make the state and vehicle type required on a vehicle job, show the legal limits, require before and after meter readings, and block closing the job until the label or certificate step is ticked with a photo.
Checklist
The window film and tinting operations checklist
Print it, or hand it to whoever runs the office side.
- Every flat glass quote is built from openings with elevation, pane count, size and glass type
- Chips, cracks and failed seals are photographed before work and shown on the quote
- Each pane passes a film-to-glass check, or carries a manufacturer approval or a signed waiver
- Jobs over the manufacturer's size threshold (2,500 sq ft on the LLumar form) hold until pre-approval is attached
- Roll width is chosen per pane group and waste is priced, not absorbed
- Roll and lot numbers are recorded when film is cut, with the balance returned to stock
- Security film quotes state the purpose, the tested standard, the attachment method and that film is not bullet resistant
- Wet glaze and mechanical attachments are recorded per opening with photos
- The day-one inspection is done from 6 feet and signed by the customer
- The cure date is set from film thickness and the care sheet goes out at close
- Warranty forms are filled from the job record and signed by customer and installer
- Rebate applications are filed before installation where the utility requires it
- Vehicle jobs record state, body type, and meter readings before and after
- The state's label, sticker or certificate is issued and photographed before the car leaves
- Medical exemption documents are copied to the vehicle record before darker film is fitted
- Installer accreditations (IWFA solar control, safety and security, automotive) are tracked per person
Software options
What software window film and tinting companies actually use
Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.
Tint Wiz
Tint shops and flat glass film dealers that want one system for leads, measuring, proposals and scheduling
Built for tint and paint protection film businesses at $150 a month flat. Flat glass is measured by room, then item (window, door, transom, skylight, sidelight), with pane count and whole-inch width and height, and the area is calculated. It tracks what is left on each roll by weight or length. Its measurement help page does not describe choosing roll widths for you.
Urable
Automotive shops doing tint, paint protection film, wraps and detailing
Markets a CRM for window tinting shops, priced at $70, $110 and $183 a month across three plans. The pages read describe vehicle work; flat glass pane measuring is not mentioned.
OrbisX
Automotive detailers, tinters and wrap shops that want a visualizer and a warranty record
One plan at $100 a month, described on its site as limited-time pricing, with a wrap, tint and paint protection film visualizer and a warranty system.
Shopmonkey
Multi-location automotive tint and accessory shops
A general auto shop system. In 2020 it announced a partnership covering franchise owners at 80 Tint World locations for scheduling, inventory, payments and customer messages. It is not built around film or flat glass.
Film and Vinyl Designs, XPEL DAP, Eastman Core
Any shop cutting automotive patterns on a plotter
Pattern libraries, not business systems, and most shops run one beside their job software. Film and Vinyl Designs publishes $125 a month for tint patterns and $175 for tint plus paint protection film. XPEL says DAP holds over 80,000 patterns and adds nesting, quotes and invoicing. Core is Eastman's pattern software for LLumar and SunTek dealers.
Jobber and Housecall Pro
Small residential film installers who mainly need a calendar, quotes and invoices
Neither lists window tinting or window film among its industries (both list window cleaning and auto detailing). They will schedule and invoice a film job; pane takeoffs, glass checks and roll tracking would be notes and custom fields.
Published prices, compared:source: Tint Wiz, window tint and PPF business software ($150 a month flat)source: Tint Wiz Help Center, Adding and Editing Measurements (rooms, items, panes, whole inches)source: Urable, pricing (Express, Pro, Enterprise)source: OrbisX, CRM for automotive detailers and tinterssource: Shopmonkey, partnership with Tint World (20 Oct 2020)source: Film and Vinyl Designs, pricing (tint, PPF and combo pattern subscriptions)source: XPEL, DAP film cutting software (over 80,000 patterns)source: Eastman Performance Films, Core film installation software
Questions to ask any vendor
- Can I measure a building by elevation, room and opening, with pane count, size and glass type on each row?
- Can a pane be blocked from the quote when it fails a film-to-glass rule I define, until an approval is attached?
- Does the system choose or at least record the roll width per pane group, and price the waste?
- Can I record the roll and lot number at the cut and have the manufacturer warranty form fill from it?
- For security film, can each opening hold its attachment method and photos, and can the quote carry the test report?
- For vehicles, can it show the legal limit by state and body type, store meter readings and refuse to close without the label or certificate?
Bring one real window film and tinting job. We show it running in Fieldproxy.
Get DemoHow Fieldproxy is set up for this
Window film and tinting on Fieldproxy: built around how you already work
A Fieldproxy setup for a window film company is built on the opening: every pane group has its elevation, size, glass type and the film that went on it. The takeoff feeds the film-to-glass check, the roll layout, the quote, the install checklist and the warranty form, so nothing is typed twice. Vehicle work runs beside it with the state limits, meter readings and the label step on each car.
Module 1
Sites, elevations and openings
A film job is hundreds of panes, and every later document asks which ones.
- Record: Site, linked to Customer and Property Manager, with access hours, lift or ladder needs and parking
- Child record: Opening (elevation N, S, E or W, floor, room, opening ID, item type, pane count, width and height in inches, square feet calculated)
- Glass fields on each opening: type, single pane or insulated unit, thickness, low-E surface, frame and gasket material, partial shading, existing film
- Condition field with a required photo for any chip, crack, scratch or fogged unit found at survey
- Import from a spreadsheet or a marked-up plan for large buildings, and copy a typical floor to the floors above it
Module 2
Film-to-glass check
Thermal breakage and seal failure are the claims that wipe out a job's margin.
- Rule table per film product, entered from the manufacturer's current warranty: maximum pane area, maximum insulated unit area, maximum thickness, excluded glass types, shading and damage rules (e.g. the Solar Gard sample form's 100 sq ft, 40 sq ft and 3/8 inch limits)
- Each opening gets a status: pass, needs manufacturer approval, or excluded
- Block: an opening marked needs approval can't go on a quote until the approval letter is attached or the customer signs a waiver for that opening
- Job-level flag when total area passes the manufacturer's pre-approval threshold (e.g. 2,500 sq ft)
Module 3
Takeoff, roll layout and quote
Margin is decided by which roll width each pane is cut from.
- Film catalogue: product, thickness in mil, available roll widths (36, 48, 60, 72 inch), cost per linear foot, NFRC values and warranty term
- Quote lines group openings by film and width, show linear feet to cut and the waste strip, and price per square foot installed
- Add-on lines: old film removal, lift hire, after-hours labor, furniture moves, wet glaze or mechanical attachment per linear foot of perimeter
- Proposal PDF on your template with the opening schedule, film data sheet, the security film wording and the care instructions
- Statuses: surveyed, checked, quoted, pre-approval, approved, film ordered, scheduled
Module 4
Film stock by roll and lot
The warranty form and any batch recall both ask for the lot number.
- Record: Roll (product, width, lot or run number, received date, starting length, balance, location in shop or van)
- Cut log: job, openings, linear feet taken, installer, with the balance updated
- Rule: a film line on a job can't be marked installed without a roll selected
- Reorder point per product and width, and a report of offcuts by width that fit small panes
Module 5
Scheduling crews and access
Commercial film goes on after hours, floor by floor, around tenants.
- Job split into visits by floor or elevation, each with its openings, crew and access window
- Crew skills: safety and security film, wet glaze, exterior film, lift ticket, IWFA accreditation held
- Block on assigning an anchored security film visit to a crew with no one trained on attachment systems
- Tenant notice sent before each visit with the rooms affected and the 48 hour windows-closed note where your film's care sheet calls for it
Module 6
Install checklist in the field app
The proof that it was done right is made on the day or not at all.
- Per opening: before photo, glass cleaned, film and roll confirmed, side applied, edge gap within your tolerance, splice position, after photo
- Attachment record for security film: daylight, edge to edge, wet glaze (sealant product, bite onto glass and frame) or mechanical, with a close-up photo
- Day-one inspection step from 6 feet with the customer, with a list of any noted items and a signature
- Cure date set from film thickness (30, 60, 90 or 140 days) and shown on the job and to the customer
- Works offline in plant rooms and basements, and syncs when the phone is back in signal
Module 7
Warranty, rebate and close-out packet
Three different outside parties want the same facts in three different layouts.
- Manufacturer warranty form filled from the job: customer, dealer, install date, film product, lot or run number, square feet per film and per elevation, glass type and thickness, both signatures
- Rebate record: utility, programme, application number, submitted before install yes or no, qualifying elevations and square feet, film SHGC, amount expected and received
- Close-out PDF: opening schedule, before and after photos, inspection sign-off, warranty, data sheets and test reports
- Customer portal where a property manager with 40 buildings finds each packet by site
Module 8
Vehicle tint jobs
A car is a 90 minute job with a legal document attached.
- Record: Vehicle (year, make, model, body type, state, VIN optional) linked to Customer
- State rule table you maintain: limit per window position by body type, reflectance, tolerance, and the label, sticker or certificate the installer must issue
- Per window: factory meter reading, film and shade, combined reading after
- Block: the job can't close until the state's installer step is ticked with a photo, and a shade below the limit needs a medical exemption document or a signed customer acknowledgement, as your policy sets
- Bay calendar with pattern cut, install and handover times, and a text when the car is ready
Module 9
Multi-site programs
School districts, banks and retailers buy security film for every building at once.
- Program record over many sites with a standard film, attachment method and price per square foot
- Site statuses: surveyed, quoted, approved, scheduled, installed, inspected, packet sent
- For a Texas district: openings tagged as ground-level near an exterior door, glass door or door-adjacent, so the district sees which of the rule's cases each one answers
- Progress billing by site or by month, with retainage where the contract has it
Module 10
Callbacks, claims and reporting
Square feet per installer and remakes per job are the numbers that run this trade.
- Callback record tied to the opening: issue (bubble, edge lift, contamination, crack, seal failure), inside cure period or not, photo, outcome
- Glass breakage claim record with the pre-work photo, the film-to-glass check and the warranty reference pulled in
- Dashboard: square feet installed per installer per day, waste by film and width, remake rate, quote win rate by film family, rebates outstanding
- Installer record with IWFA accreditations and manufacturer training dates
The AI agents, set up for window film and tinting companies
| Agent | When | What it does | What you get |
|---|---|---|---|
| Vision agent | The surveyor photographs an opening, a spacer stamp or a chipped edge | Reads the photo for pane count, visible damage, wired or textured glass and any maker and date stamped on the spacer, and fills those fields on the opening | A draft opening row with glass fields and a damage flag for the surveyor to confirm before the film-to-glass check runs |
| Document intelligence agent | A general contractor or school district sends a window schedule, bid specification or purchase order as a PDF | Pulls out the openings with sizes and counts, the film specified, the attachment method and any standard named, and notes where a specification cites ASTM F3561 for retrofit film | A job with openings loaded, a quote draft, and a note to sales listing the specification points to query |
| Watcher agent | A job is about to be scheduled, or a film line is marked installed | Checks for openings still marked needs approval, a missing manufacturer pre-approval over the size threshold, a rebate that needed filing before install, a missing roll and lot number, or a vehicle job with no label photo | A block on the job with the exact missing item, and an alert to the project manager |
| Text agent | A customer texts or emails about bubbles, haze or cleaning after an install | Looks up the job, the film thickness, the install date and the cure date, and answers from your care sheet. If the cure date has passed or the message mentions a crack, it opens a callback against the site | A reply with the cure date and care steps, or a callback record with the customer's photo for the office to schedule |
| Autopilot | A quote sits unanswered, a warranty form is unsigned 7 days after install (e.g.), or a rebate has not paid | Drafts the follow-up with the opening count, the film and the amount, and attaches the form or proposal it refers to | A message for the office to approve and send |
| Scheduler agent | Every Monday morning (e.g.) | Compiles square feet installed per installer, waste by roll width, callbacks opened inside and outside cure, and program sites by status | A weekly email to the owner and each program's customer contact |
Straight answers
Window film and tinting: FAQ
What software do window film and tinting companies use?
Tint Wiz is the tool built for this trade and covers both flat glass and vehicles. Automotive shops also use Urable, OrbisX or Shopmonkey, and nearly all run pattern cutting software such as Film and Vinyl Designs, XPEL DAP or Eastman Core beside it. Jobber, Housecall Pro and ServiceTitan do not list window film as an industry. Larger commercial dealers often need more than a tint shop tool: pane-level takeoffs, film-to-glass checks, roll and lot tracking and multi-site programs.
How long does window film take to cure?
The IWFA guideline gives typical visual cure times by thickness: up to 4 mil 30 days, 4 to 8 mil 60 days, 8 to 12 mil 90 days, and over 12 up to 17 mil 140 days, varying with climate. Haze and water bubbles during that time are not defects. Manufacturer care sheets say not to clean the film for 30 days and not to use ammonia based cleaners.
How is window film inspected for defects?
Under the IWFA guideline, from the room side at right angles, from at least 6 feet, in natural daylight but not direct sun, ignoring a 2 inch band at the edges. The film passes if dirt, hairs, bubbles, scratches and creases are unobtrusive from there. Edge gaps are normally 1/32 to 1/16 inch. Inspection can happen within a day of installation.
Can window film crack glass?
It can contribute. NFRC's consumer guide says film increases the glass temperature and may cause thermal stress on the glass or insulated glazing seals. That is why manufacturers list glass they will not warrant, such as very large panes, thick or wired glass, damaged glass and partly shaded glass, and why a film-to-glass check on every pane comes before the quote.
Is security window film bulletproof?
No. The International Window Film Association says safety and security film is not bullet-resistant and should not be represented as stopping bullets. Its role is to hold broken glass together and delay entry, and attachment systems that tie the film to the frame are strongly recommended. IWFA also says ASTM F3561 was not designed to evaluate retrofit film.
What does Texas require for school windows?
19 TAC 103.1215 (formerly 61.1031) requires that ground-level windows near exterior doors that would permit entry if broken, glass exterior doors, and windows beside a door that would allow someone to reach in, cannot be easily broken. It gives forced entry-resistant film as an example and names no test standard or thickness. Windows inside an exterior secured area are excluded.
What does a manufacturer need to register a film warranty?
The forms read for this guide ask for the customer and dealer details, install date, film product, lot or run number or roll number, and square footage, with LLumar also asking for glass type, thickness, coatings and pane type, and Solar Gard asking for film and area by elevation. Both need signatures. LLumar's form requires pre-approval over 2,500 square feet and says the warranty is not transferable.
Can a tint shop be fined for installing illegal tint?
In several states, yes. Texas makes it a misdemeanor with a fine up to $1,000 for a business to install film without the required label. Florida makes selling or installing film in violation a second degree misdemeanor. Illinois and Georgia both bar the installation itself. Federal law also bars repair businesses from knowingly making safety equipment inoperative.
Do utilities pay rebates for window film?
Some do, with conditions. Austin Energy lists $1.80 per square foot for film with a solar heat gain coefficient of 0.37 or less, applied for before installation. Efficiency Works in northern Colorado lists $1.50 per square foot at 0.35 or less on windows facing within 45 degrees of west, south or east. Georgia Power lists $1 per square foot at 0.24 or less on south, east or west windows.
What widths does window film come in?
Architectural film is commonly sold in 36, 48 and 60 inch rolls, with some safety and dry adhesive films in 72 inch, priced per 100 linear feet. Because film is bought by the linear foot, the roll width chosen for each pane size decides how much is wasted.
Does Fieldproxy have a window film template?
No fixed template. Fieldproxy is set up around how your company runs: openings by elevation, your film-to-glass rules, roll and lot stock, the install and inspection checklist, warranty and rebate forms on your layouts, and vehicle jobs with your states' limits. It works offline in the field app and syncs to QuickBooks or Xero.
Related guides
All sources on this page (55)
- source: IWFA, Architectural Visual Inspection Guideline For Applied Window Film (1 Jan 2020), including Table 1 Typical Cure Times
- source: LLumar (Eastman) architectural warranty and installation record, form L2097 (06/16)
- source: Texas Transportation Code 547.613, Restrictions on Windows (public.law copy)
- source: Federal Register 81 FR 15427 (23 Mar 2016), CPSC Safety Standard for Architectural Glazing Materials: Category I 150 ft-lb, Category II 400 ft-lb, ANSI Z97.1-2015 test
- source: 16 CFR 1201.2 Definitions (Cornell LII): Category I and II products, organic-coated glass, permanent label
- source: NFRC Efficient Windows guide, Window Film (thermal stress on glass and insulated glazing seals)
- source: Solar Gard (Saint-Gobain), Limited Residential/Commercial Warranty SK0375PAN, sample form: glass breakage and IG seal failure terms and excluded glass
- source: NFRC fact sheet hosted by IWFA, The Basics About Window Films (label contents, CPD number)
- source: Energy Code Ace, California Title 24 Part 6 Reference Appendix NA7.4.2 Window Films
- source: IWFA, Specifying Safety and Security Window Film for Delayed Entry (2024)
- source: Intertek, ASTM F3561 forced entry resistance of fenestration systems after simulated active shooter attack
- source: IWFA, Statements on Protection from and against Ballistics (ASTM F3561 and retrofit film)
- source: IWFA, Safety and Security Education Guide (2026): impact test, install methods, wet glaze bite
- source: Solar Gard, GSA Blast Testing Summary (GSA TS01-2003 performance conditions and anchoring systems)
- source: National Glass Association, Glass Technical Paper FB12-07 (2023), Blast Resistant Glazing
- source: Solar Gard Tech Bulletin PDF0250, Visual Inspection and Maintenance of Window Film (05/22)
- source: Avery Dennison, Solar Films Maintenance Recommendations
- source: Tint Depot tinting school, Installing Film on Architectural Glass (roll widths, 100 linear feet, waste)
- source: IWFA, Accreditation Tests (four individual accreditations, 80 percent pass mark, $50 members and $100 non-members per test)
- source: Austin Energy, commercial window film and solar shading rebate
- source: Efficiency Works Business (Colorado), Envelope rebate incentives and conditions (revised Jan 2026)
- source: Georgia Power, Commercial Energy Efficiency Program, Building Envelope sheet (2026)
- source: Texas Education Agency, adopted new 19 TAC 103.1215 School Safety Requirements (2026)
- source: 49 U.S. Code 30122, Making safety devices and elements inoperative (Cornell LII)
- source: 49 CFR 571.205, Standard No. 205, Glazing materials (Cornell LII)
- source: California Vehicle Code 26708 (FindLaw copy, current as of 1 Jan 2026)
- source: Florida Statutes 316.2955, installer label and plus or minus 3 percent tolerance
- source: New York DMV, Tinted Windows (70 percent rule, checked at inspection since 1 Jan 2017)
- source: New York DMV, form MV-80W Application for Tinted Window Exemption (6/24)
- source: Illinois 625 ILCS 5/12-503 (FindLaw copy): installer liability, penalties, medical statement kept by installer
- source: Texas Transportation Code 547.609, Required Label for Sunscreening Devices (public.law copy)
- source: Florida Statutes 316.2953, side windows forward of the driver
- source: Florida Statutes 316.2954, windows behind the driver
- source: Florida Statutes 316.2956, penalty for selling or installing sunscreening material in violation
- source: Washington RCW 46.37.430, safety glazing and sunscreening (installer sticker on the driver's door post)
- source: Georgia O.C.G.A. 40-8-73.1 (FindLaw copy): 32 percent plus or minus 3 percent
- source: IWFA, Interactive Tint Laws (state by state, by vehicle type)
- source: IWFA, New York Passes Legislature Making 50% VLT Legal, Updating Current Law (3 Jun 2026; bill sent to the governor)
- source: Tint Wiz, window tint and PPF business software ($150 a month flat)
- source: Tint Wiz Help Center, Adding and Editing Measurements (rooms, items, panes, whole inches)
- source: Urable, pricing (Express, Pro, Enterprise)
- source: OrbisX, CRM for automotive detailers and tinters
- source: Shopmonkey, partnership with Tint World (20 Oct 2020)
- source: Film and Vinyl Designs, pricing (tint, PPF and combo pattern subscriptions)
- source: XPEL, DAP film cutting software (over 80,000 patterns)
- source: Eastman Performance Films, Core film installation software
Run window film and tinting work the way it actually runs.
A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.
Get a walkthroughOne price per company. Unlimited users.