Guide for propane and heating oil dealers ยท checked 19 November 2026
Propane and heating oil dealer software that runs deliveries, tank sets, leak checks and service
A fuel dealer runs two businesses on one customer: the truck that keeps the tank above empty, and the service department that sets tanks, checks for leaks and fixes the furnace. The delivery side is weather math and DOT paperwork. The service side is NFPA 54 and 58, and the out-of-gas call that ends in a lawsuit when nobody wrote down the leak check. This guide covers how degree-day delivery works, the out-of-gas rules in Iowa and Mississippi, bobtail hose and cargo tank intervals, the CETP to PEP training change, and how to set a dealer up so every tank, fill and leak check is on file.
See your own jobs set up this way
A 30-minute call. We show you propane and heating oil dealers workflows running in Fieldproxy, built around how you work.
Short answer
Propane and heating oil dealers mostly run on fuel-industry back-office systems: ADD Systems (ADD Energy E3 with RAVEN delivery handhelds and Pegasus for service technicians), PDI Propane and Commercial Fueling (the former Blue Cow Software products, bought by PDI in 2023), Cargas Energy (delivery, HVAC service and cylinder exchange, with the MyFuelPortal customer portal it bought in 2026) and Energy-Force. Tank monitors such as Anova feed tank levels into those systems. Whatever you use, check that it holds each tank's K-factor and fill history, every out-of-gas leak check with start and end pressures, tank set and piping test records, driver hazmat training dates and bobtail hose inspections. Fieldproxy is one option. Best for processes that don't fit a template, set up for you: often run alongside the delivery system for the service department, tank sets and compliance records.
NFPA 54 8.2.3
Leak check required immediately after gas is turned on into a system restored after an interruption of service
Tag and shut
Iowa rule for an out-of-gas fill: close the service valve and tag it until a qualified person leak checks the system
Every 3 years
Recurrent hazmat employee training for drivers under 49 CFR 172.704, with records kept
source: 49 CFR 172.704, Hazmat employee training requirements (via Cornell LII)
Monthly
Visual inspection of every bobtail delivery hose assembly while in service, 49 CFR 180.416
How a job runs
One propane and heating oil delivery job, from first call to paid
The order the work really happens in, and what has to be written down at each step so nothing is argued about later.
- 1
Sign up the customer and survey the site
Take the account, the address and the appliances: furnace or boiler, water heater, range, dryer, fireplace, generator, pool heater. For a new propane customer, walk the site for the tank location, distances to the building and property line, the regulator and the piping run. For oil, note the tank, its age, the supply line and whether it is sleeved or has an oil safety valve.
- 2
Set the tank and test the piping
Set the container, install first and second stage regulators, run and pressure test the line, then leak check after gas is introduced. Iowa's rule is a useful example of the test detail: piping above 20 psig is tested at 50 to 75 psi for at least half an hour per 500 cubic feet of pipe volume, 10 minutes for systems under 10 cubic feet, with air, nitrogen, carbon dioxide or inert gas and never oxygen. Systems at 20 psig or less follow NFPA 54.
- 3
Put the tank on automatic delivery
Give the tank a starting K-factor and a daily use figure for non-heating appliances. Degree days post every day; the system estimates how much is left and schedules the stop before the tank hits the reorder level. After each delivery the K-factor is recalculated from the gallons actually delivered. Will-call customers phone in instead, and they are the ones who run out.
- 4
Build routes and load the trucks
Pull the tanks due in the next few days, group them by area and truck capacity, and check access notes (gate codes, dogs, a plowed driveway). Drivers carry shipping papers for the load. A tank monitor on high-use or hard-to-reach tanks replaces the estimate with a real reading.
- 5
Make the delivery and print the ticket
The driver fills to the fixed maximum liquid level gauge, never past 80 percent for propane, records the meter reading and gallons, and leaves a ticket. If the gauge reads zero or the customer said they ran out, the delivery becomes an out-of-gas call and the next step applies before the system is turned back on.
- 6
Handle the out-of-gas or interruption of service
Close the service valve. If the customer is away, tag the valve as out of service. A qualified person leak checks the system: start and end pressures, how long the pressure held, date and time, and gas in the tank. Only then is the system put back in service, and appliances relit if company policy says so, with each appliance listed.
- 7
Run the service department
Heating season brings no-heat calls, annual tune-ups for oil burners and gas furnaces, regulator replacements, generator and pool heater hookups. Each call records the appliance, the work and any leak check. Oil customers in Massachusetts with lines that touch the floor need a sleeve or an oil safety valve certified by a licensed oil burner technician.
- 8
Run cylinder exchange and fills
Exchange cages at retail sites are restocked on a schedule. Cylinders filled at the plant are checked for the requalification date, valve condition and DOT marking before filling, and filled by weight or the fixed liquid level gauge.
- 9
Bill deliveries, budget plans and pre-buy contracts
Deliveries bill per gallon at the posted or contract price. Budget customers pay a fixed amount each month across the year, settled at the end of the plan year. Pre-buy customers locked in gallons at a set price before the season; each delivery draws down that balance. Some states regulate prepaid fuel contracts, so check yours before taking pre-buy money.
- 10
Close the year: renewals, tank swaps and training
Renew budget and pre-buy contracts before the season, swap or requalify cylinders that are due, pull tanks from customers who left, and check every driver's hazmat training, CDL endorsements and PEP or CETP certificates before winter.
What to record
The fields every propane and heating oil delivery job should capture
Tank and site, per customer
- Tank: owner (dealer or customer), serial, water capacity, ASME or DOT, manufacture date, aboveground or underground, install date and installer
- Location: distance to the building, property line and nearest opening, with a photo and sketch
- Regulators and piping: first and second stage regulator dates, line material, last pressure test with pressure and duration
- Appliances served, with BTU input, and whether the site has a generator or pool heater
- For oil: tank type and age, supply line sleeved or oil safety valve fitted, Massachusetts certification form where it applies
Delivery, per fill
- Meter start and end, gallons, gauge reading before and after, fill stopped at the fixed maximum liquid level gauge
- Degree days since the last fill and the recalculated K-factor
- Out-of-gas or interruption flag: gauge read zero, customer reported running out, or service was shut off
- Price basis: posted, budget, pre-buy draw or contract, with the balance left
- Driver, truck, time on site, customer note and access issues
Leak check and service call
- Reason: new system, out of gas, interruption of service, odor call, regulator or appliance change, new occupant
- Method (low, intermediate or high pressure, or vapor meter), gauge used, start and end pressures, time held, start and end times
- Gas in the tank at the time, result, what was repaired if it failed, and the tag left if the system was shut off
- Appliances present and relit, one line each, including electronic ignition units
- Customer present or not, customer acknowledgment, technician and their certification
Driver, truck and cylinder
- Driver: CDL class, H, N or X endorsement, hazmat training date and next due, PEP or CETP certificates
- Cargo tank: external visual and leakage test dates (yearly), internal visual and pressure test dates (every 5 years)
- Delivery hose: ID number, manufacturer, assembly and test date, monthly inspection with pass or fail and inspector
- Cylinder: DOT specification, manufacture or last requalification date, condition at fill, filled by weight or gauge
Rules and standards
The rules that shape the work, with their sources
| Rule | What it means on the job |
|---|---|
| NFPA 54 8.2.3: leak check after an interruption of service | As quoted from the 2012 edition: immediately after gas is turned on into a new system, or into a system that has been initially restored after an interruption of service, the piping system shall be checked for leakage; where leakage is indicated, the gas supply shall be shut off until repairs are made. Leaks are found with an approved gas detector or noncorrosive leak detection fluid, never a flame. Confirm the numbering in the edition your state adopts. source: Oil & Energy Online, Test for leaks when propane service is interrupted (quotes NFPA 54 8.2.3, 2014) |
| Placing a system in service is not the same as placing it in operation | John McCoy's reading of NFPA 54: putting a system back in service needs a leak check, which can be done from outside the house. Putting appliances in operation also needs the piping leak checked and purged and the appliances purged before lighting (8.2.4 and 8.3.3 in the edition he cites). Plaintiffs have argued purging is always required after an out-of-gas call; the wording is the defense. source: LP Gas magazine, John McCoy, Distinction exists between placing gas system into service, in operation (2013) |
| Iowa: out-of-gas customers and interruption of service | 661-226.5(4): when propane is delivered to a container that is out of gas, or service was interrupted, the delivery person shuts off the container service valve. If the customer is not present, a tag goes on the valve saying the container is out of service and a qualified person must leak check before it is turned on. If the customer is present, they are told the same. 226.5(2) applies the NFPA 54 Section 8.2 leak check after gas is turned on. source: Iowa Administrative Code 661-226.5 (pressure testing, leak check, out-of-gas start-up procedure) |
| Iowa: pressure tests for piping over 20 psig | 661-226.5(1): test with air, nitrogen, carbon dioxide or inert gas, never oxygen, at no less than 50 psi and no more than 75 psi, for at least half an hour per 500 cubic feet of pipe volume (10 minutes for systems under 10 cubic feet). Piping at 20 psig or less, and polyethylene piping, follows NFPA 54. Propane liquid may not be used to leak test high-pressure systems. source: Iowa Administrative Code 661-226.5 (pressure testing, leak check, out-of-gas start-up procedure) |
| Mississippi: leak check on interruption or first service, records on file | 19 Miss. Code R. 7-14.04 requires a leak check on any interruption of service to an existing system or first time service of a new customer. Records list the items checked and the results, are kept on file at the branch serving the customer and shown to LP gas inspectors on request. It recommends a customer aged 18 or over be present and sign. source: Mississippi 19 Miss. Code R. 7-14.04, Leak check procedures and requirements (via Cornell LII) |
| What an out-of-gas record has to show | Defense attorney John McCoy: do a leak check on every out-of-gas call and whenever the gauge reads zero at fill, even if the bleeder shows pressure. Record start and end test pressures, how long pressure held, date and time, and gas in the tank. A line saying 'leak check passed' on a delivery ticket is not enough. If staff relight appliances, list each one. source: LP Gas magazine, John McCoy, Servicing out-of-gas calls (2020) |
| When to leak check beyond out of gas | ThompsonGas's Benny Gay lists installing or replacing a container, meter, appliance, regulator or piping, any shutoff (seasonal or brief), running out of gas, and odor calls; and recommends a check when one occupant moves out and another moves in. Record beginning and ending gauge readings, start and end times and the customer's acknowledgment. source: LP Gas magazine, Benny Gay (ThompsonGas), Complete thorough system leak checks (2023) |
| Hazmat employee training (the HM-126F rule) | 49 CFR 172.704, the subpart created by the 1992 HM-126F rulemaking: general awareness, function-specific, safety and security awareness training, within 90 days of hire or a job change (supervised until then), repeated at least every three years. Records hold the employee's name, last completion date, materials, the trainer's name and address and a certification, kept while employed and 90 days after. source: 49 CFR 172.704, Hazmat employee training requirements (via Cornell LII) |
| CDL tank and hazmat endorsements | A tank vehicle is a commercial vehicle carrying liquid or gas in one or more tanks over 119 gallons each with an aggregate of 1,000 gallons or more (49 CFR 383.5). The licence shows N for tank vehicles, H for hazardous materials and X for the two combined (49 CFR 383.153). A placarded bobtail or transport driver needs both. source: 49 CFR 383.153, CDL endorsement codes H, N and X (via Cornell LII) |
| Cargo tank test intervals for propane bobtails (MC 331) | 49 CFR 180.407(c): external visual inspection and leakage test every year, internal visual inspection and pressure test every 5 years. Small tanks under 3,500 gallons water capacity in dedicated propane service made of NQT SA-612 steel can go 10 years on internal visual and pressure tests. Retest dates run from the most recent inspection. source: 49 CFR 180.407, Cargo tank test and inspection intervals (via Cornell LII) |
| Delivery hose and discharge system inspections | 49 CFR 180.416: visually inspect each delivery hose assembly and the piping every calendar month in service, actuate emergency discharge controls monthly, and check the internal self-closing stop valve for leakage (a meter creep test is allowed on metered tanks). New or repaired hoses are tested at 120 percent of maximum working pressure. Records hold date, inspector, hose ID, manufacturer, assembly and test date and pass or fail. source: 49 CFR 180.416, Discharge system inspection and maintenance for cargo tanks (via Cornell LII) |
| CETP is becoming PEP | New Jersey's DCA memo: through 2025 PERC phased out the Certified Employee Training Program and stopped offering CETP 1.0, 2.2 (bobtail) and 2.4 (cylinder delivery), replaced by PEP learning paths with on-the-job training worksheets signed by a PEP-recognized field trainer. In New Jersey, CETP 4.1 and 4.2 were archived on 30 Nov 2025; the 2026 bobtail path includes leak check OJTs by high, intermediate and low pressure and vapor meter. source: New Jersey DCA, LP-Gas education and training memo: CETP to PEP transition (2025, updated 2 Jan 2026) |
| Cylinder filling and requalification | Utah's fire marshal guidance: fill propane containers to 80 percent, by fixed liquid level gauge or by weight, never by a float gauge, and stop when liquid mist appears. Federal rule 49 CFR 180.209 sets requalification periods; Utah's sheet summarizes it as within 12 years of manufacture and every 5 years after, while 180.209 also allows longer periods for coated cylinders in non-corrosive service, so check the method used. source: Utah State Fire Marshal, LP-Gas basic filling procedures, general information |
| NORA oilheat technician certification | The National Oilheat Research Alliance runs three levels: Bronze for technicians learning the basics, Silver after at least three years of service experience and a comprehensive exam on the Oilheat Technicians Manual, and Gold for current Silver holders with five years on oilheat systems and four Advanced Training modules. Silver and Gold renew with 24 CEUs. Some states also license oil burner technicians separately. source: National Oilheat Research Alliance (NORA), Technician certification program |
| Massachusetts: oil supply lines that touch the floor | M.G.L. c. 148, s. 38J: owners of 1 to 4 unit homes whose oil supply or return lines touch concrete, earth or the floor must sleeve the supply line, fit an oil safety valve at the tank end, or use another approved method. Lines upgraded on or after 1 Jan 1990 to 527 CMR are exempt. A licensed oil burner technician inspects and certifies on the state form, filed with the local fire department. source: Massachusetts General Laws c. 148, s. 38J, oil safety valve or sleeved supply line (via Onecle) |
Rules vary by state, council and contract. Checked 19 November 2026; confirm against the source for your area before relying on it.
Numbers
Delivery math, test intervals and training dates at a glance
Regulation rows are from the rules linked; setbacks are a county's summary of NFPA 58 and should be checked against your adopted edition. The K-factor example is arithmetic from the Energy-Force definition (degree days per gallon), not a vendor claim.
| Item | Figure | Basis |
|---|---|---|
| Heating degree days | 65ยฐF minus the average of the day's high and low | Energy-Force help center |
| K-factor | Degree days to burn one gallon; recalculated after each delivery | Energy-Force help center |
| Worked example: 500 gal tank, deliver at 25% | 80% minus 25% = 275 usable gallons | Arithmetic |
| Same tank, K-factor 5, 30 HDD a day, 1.5 gal/day water heater | 6 + 1.5 = 7.5 gal/day, so about 36 days between fills | Arithmetic |
| Propane fill limit | 80% of container capacity | Utah fire marshal |
| Aboveground setback, 125 to 500 gal | 10 ft from structure | Larimer County |
| Aboveground setback, 501 to 2,000 gal | 25 ft from buildings and property lines | Larimer County |
| Relief valve discharge | At least 5 ft horizontally from openings below it | Larimer County |
| Piping test over 20 psig (Iowa) | 50 to 75 psi, 30 min per 500 cu ft | IAC 661-226.5 |
| Bobtail external visual and leakage test | Every year | 49 CFR 180.407 |
| Bobtail internal visual and pressure test | Every 5 years | 49 CFR 180.407 |
| Delivery hose visual inspection | Every calendar month in service | 49 CFR 180.416 |
| Hazmat training | Within 90 days of hire, then every 3 years | 49 CFR 172.704 |
| Households heating mainly with propane / heating oil, US 2026 | 6.36 million / 4.13 million (3.39 million of the oil homes in the Northeast) | EIA Winter Fuels Outlook |
source: Energy-Force Help Center, K-factors and degree days basicssource: Utah State Fire Marshal, LP-Gas basic filling procedures, general informationsource: Larimer County, Colorado, Liquid propane: general requirements (setbacks and relief valve discharge)source: Iowa Administrative Code 661-226.5 (pressure testing, leak check, out-of-gas start-up procedure)source: 49 CFR 180.407, Cargo tank test and inspection intervals (via Cornell LII)source: 49 CFR 180.416, Discharge system inspection and maintenance for cargo tanks (via Cornell LII)source: 49 CFR 172.704, Hazmat employee training requirements (via Cornell LII)source: 49 CFR 383.5, Definitions (tank vehicle) (via Cornell LII)source: 49 CFR 180.209, Requalification of specification cylinders (via Cornell LII)source: US EIA, Winter Fuels Outlook 2026 to 2027 (Short-Term Energy Outlook supplement)
Where it breaks
Where spreadsheets and generic software fall over
A driver fills a tank that read zero, writes 'leak check OK' on the ticket and leaves. A week later there is a fire and the dealer's only record is four words.
A delivery with a zero gauge reading or a reported run-out opens a leak check record that needs method, start and end pressure, time held, gas in tank and appliances relit. The ticket can't close until it is filled or the valve is marked shut and tagged.
The K-factor was set when the customer moved in. They added a pool heater and a generator, and the will-call style run-outs start in January.
K-factor is recalculated from gallons and degree days at every fill. A fill that comes in well above the forecast flags the account for review, and adding an appliance on a service call updates the daily use figure.
Delivery runs in the fuel ERP, service runs on paper. The tech on a no-heat call has no idea the tank was filled from empty yesterday without a leak check.
Service and delivery share one site record. The tech sees the last fill, the out-of-gas flag and the last leak check result before walking in.
A new driver starts in October and runs a bobtail alone in week two. His hazmat training is not done and his licence has H but not N.
Driver records hold endorsements and training dates. A route can only be assigned to a driver whose CDL shows X (or H and N) and whose hazmat training is current, or who is flagged as supervised.
Monthly hose inspections live on a clipboard in the truck. The DOT auditor asks for March and nobody can find it.
Each hose has an ID, and the monthly inspection is a checklist on the driver's phone with pass or fail. A truck whose hose check is overdue can't be loaded.
A customer leaves, the dealer-owned tank stays in their yard, and the new owner fills it from a competitor.
Tanks are assets with an owner field. Closing an account creates a pull or transfer task, and a dealer-owned tank with no active customer appears on the weekly list until it is picked up or leased.
Checklist
The propane and heating oil delivery operations checklist
Print it, or hand it to whoever runs the office side.
- Every tank has an owner, serial, capacity, location sketch and setback distances on file
- New systems pressure tested and leak checked, with test pressure, medium and duration recorded
- Every out-of-gas or interruption call has a leak check record with start and end pressures, or a tag left
- Appliances relit are listed one by one when company policy is to relight
- K-factor recalculated at every delivery; big misses flagged for review
- Tank monitors on high-use, hard-to-reach and run-out-history tanks
- Fills stop at the fixed maximum liquid level gauge, 80 percent for propane
- Drivers: CDL with X (or H and N), hazmat training within 90 days and every 3 years
- PEP or CETP certificates on file for drivers, cylinder fillers and service techs
- Bobtail hoses inspected monthly; cargo tanks tested yearly and every 5 years as due
- Cylinders checked for requalification date and condition before every fill
- Oil customers: sleeve or oil safety valve recorded where the state requires it
- Budget and pre-buy contracts renewed before the season, with balances reconciled
- Dealer-owned tanks at closed accounts pulled or leased
Software options
What software propane and heating oil dealers actually use
Judge each one on whether it fits the way your jobs run, not on the feature list. Bring a real job to every demo.
ADD Systems (ADD Energy E3, RAVEN, Pegasus)
Mid and large propane and heating oil marketers that want one fuel back office
ADD's site describes ADD Energy E3 for receivables, credit, delivery, service and inventory, RAVEN to take the system into the delivery truck, and Pegasus for wireless communication with service technicians. In business since 1973 (its site marks 50 years). Pricing is not published. Deep on fuel accounting and delivery; the service and compliance screens are what you get, not what you design.
PDI Propane and Commercial Fueling (formerly Blue Cow Software)
Fuel oil and propane dealers wanting ERP, in-truck delivery and service, routing and a customer app
PDI bought Blue Cow Software of Middleton, Massachusetts on 15 Feb 2023, with about 375 North American customers (LP Gas magazine). The product lists ERP, In-Truck Delivery, In-Truck Service, Routing, Analytics and a customer portal and app. Case studies still call it legacy Blue Cow Ignite. Now part of a large convenience store and fuel software company.
source: PDI Propane and Commercial Fueling (formerly Blue Cow Software)
Cargas Energy
Fuel delivery and HVAC service companies, including cylinder exchange
Cargas, an employee-owned software and consulting firm founded in 1988, describes Cargas Energy as covering fuel delivery, customer service, HVAC service and cylinder exchange. It bought Silverline's MyFuelPortal customer portal on 9 Feb 2026. Pricing on request.
Energy-Force
Propane and refined fuel distributors that want tank forecasting and reconciliation
Its help center documents degree day posting, a K-factor calculator, daily use gallons and K-factors recalculated from the last two deliveries. MFA Oil's propane division picked it in July 2020 after a pilot, citing daily reconciliation, routing, forecasting and tank tracking. Little public detail on pricing or company size.
Tank monitors (Anova and others)
Context, not a system of record: dealers replacing estimates with readings
Anova's Universal Tank Monitor reads tank level, pressure and meters, samples every half hour, reports daily over LTE-M with alarms, and claims a 15+ year battery, with API integration to ERP software. Monitors feed the delivery system; they don't run it.
General field service tools (ServiceTitan, Jobber and similar)
Dealers whose service department is a full HVAC business
Good at HVAC dispatch, estimates and invoices. They do not do degree day forecasting, gallons, pre-buy balances or cargo tank records, so they run next to the fuel system, not instead of it.
Published prices, compared:source: ADD Systems, ADD Energy E3, RAVEN and Pegasussource: PDI Technologies, PDI Propane and Commercial Fuelingsource: PDI Technologies, Stringer Oil and LP Gas case study (legacy Blue Cow Ignite)source: LP Gas magazine, PDI Technologies acquires Blue Cow Software (15 Feb 2023)source: Cargas, Cargas acquires Silverline's MyFuelPortal (9 Feb 2026)source: Energy-Force Help Center, K-factors and degree days basicssource: MFA Oil Bottom Line, BPLP division to transition to Energy-Force (2020)source: Anova, Universal Tank Monitor product page
Leaving ADD Systems? Our step-by-step guide covers why propane and heating oil dealersswitch, what to export, what doesn't export and how to run both during cutover: how to switch from ADD Systems.
Leaving PDI Propane? Our step-by-step guide covers why propane dealersswitch, what to export, what doesn't export and how to run both during cutover: how to switch from PDI Propane.
Questions to ask any vendor
- Does a fill with a zero gauge reading or a reported run-out force a leak check record (method, start and end pressure, time held, gas in tank) before the ticket closes?
- Is the K-factor recalculated after every fill, with daily use for water heaters and generators, and can a tank monitor reading override the estimate?
- Can service techs see the delivery history and last leak check for the site, and can drivers see open service issues?
- Can driver records block a route when hazmat training is over 3 years old or the CDL lacks the tank or hazmat endorsement?
- Where do monthly hose inspections and yearly and 5-year cargo tank tests live, and can I print them for a DOT audit?
- How are budget plans and pre-buy gallons tracked, reconciled at year end, and shown to the customer?
Bring one real propane and heating oil delivery job. We show it running in Fieldproxy.
Get DemoHow Fieldproxy is set up for this
Propane and heating oil delivery on Fieldproxy: built around how you already work
A Fieldproxy setup for a fuel dealer is built around the tank and the gas system behind it: each site carries its tank, regulators, piping tests and appliances, each fill its gauge readings and K-factor, each out-of-gas call its leak check, each driver and truck their DOT records. Gates stop a ticket closing on an out-of-gas fill without a leak check, a route going to a driver without current hazmat training, and a truck loading with an overdue hose check. Many dealers keep their fuel ERP for billing and use Fieldproxy for the service department, tank sets and compliance.
Module 1
Customer, site and tank survey
Every later dispute starts from where the tank is and what it feeds.
- Site record: address, access notes, appliances with BTU input, generator or pool heater, occupancy (owner or tenant)
- Tank asset: owner (dealer or customer), serial, water capacity, ASME or DOT, manufacture date, above or below ground, setbacks with photo and sketch
- Regulators and piping: stage, install date, line material, last pressure test
- Oil sites: tank age and type, supply line sleeved or oil safety valve, state certification form where required
- Status: Lead, Surveyed, Quoted, Tank set, Tested, In service, Out of service, Pulled
Module 2
Tank sets, piping tests and installs
A new system is only in service after the test is written down.
- Install job with checklist: container placement and distances, regulators, line run, pressure test, leak check after gas introduced
- Pressure test fields: medium (air, nitrogen, CO2, inert), test pressure, gauge range, start and end, duration against pipe volume (e.g. Iowa's 30 minutes per 500 cu ft)
- Rule: a tank can't be marked In service until the pressure test and the leak check are both recorded
- Permit number and inspection date where the county requires one
- Tank set quote with tank lease or purchase, regulator, line and labor lines
Module 3
Automatic delivery and K-factor forecast
Run-outs cost more than a wasted trip, because each one is a leak check and a liability.
- Per tank: K-factor, daily use gallons, reorder level (e.g. 25 percent), will-call or automatic
- Degree days posted daily; estimated percent left recalculated each day
- K-factor recalculated at each fill from gallons and degree days; a miss over a set margin (e.g. 20 percent) flags review
- Tank monitor readings imported where fitted, replacing the estimate for that tank
- Due list grouped by area and truck capacity for the dispatcher, exported to the routing or fuel system if it does the routes
Module 4
Driver app: delivery ticket and out-of-gas gate
The driver at the tank is the only one who knows it read zero.
- Ticket: meter start and end, gallons, gauge before and after, stopped at fixed maximum liquid level gauge
- Out-of-gas question on every fill: gauge at zero, customer reported run-out, or service shut off
- Rule: a yes needs either a leak check record or a 'valve shut and tagged' record with a tag photo before the ticket closes
- Customer-not-home path sends a text that the system is shut off and a tech must check it
- Offline in rural areas, synced later, with GPS and time stamps
Module 5
Leak checks and service calls
The leak check record is the dealer's defense; the service call is its margin.
- Leak check record: reason, method (low, intermediate, high pressure, vapor meter), gauge, start and end pressure, time held, gas in tank, result
- Appliance relight list, one line per appliance, including electronic ignition
- Service job types: no heat, tune-up, regulator change, odor call, generator or pool heater hookup, oil line upgrade
- Rule: an odor call is dispatched as emergency and can't be closed without a leak check
- Customer acknowledgment and signature, and a PDF leak check certificate to the customer
Module 6
Drivers, trucks and DOT records
A DOT audit asks for months of paper that usually lives in a cab.
- Driver: CDL class, endorsements (H, N, X), medical card expiry, hazmat training date and next due, PEP or CETP certificates
- Rule: a route only goes to a driver with X (or H and N) and training under 3 years old, or flagged as supervised in the first 90 days
- Cargo tank: external visual and leakage test yearly, internal visual and pressure test every 5 years, with due dates
- Hose: ID, manufacturer, assembly and test date, monthly inspection checklist with pass or fail
- Rule: a truck with an overdue hose inspection or cargo tank test can't be assigned a load
Module 7
Cylinder exchange and fills
Cylinders are small assets with federal dates on them.
- Exchange site: cage capacity, stock count, restock schedule, empties collected
- Cylinder fill record: DOT specification, last requalification date, condition, filled by weight or gauge
- Rule: a cylinder past its requalification date can't be marked filled; it goes to requalify or scrap
- Forklift and motor fuel cylinders on recurring swaps for commercial accounts
Module 8
Budget plans, pre-buy and billing
Prepaid gallons are money the dealer is holding, and customers check the balance.
- Contract: type (budget, pre-buy, capped, posted), price, gallons, monthly amount, start and end
- Each delivery draws down pre-buy gallons; balance shown on the ticket
- Year-end reconciliation for budget accounts, with the true-up invoice or credit
- Service invoices from the job, synced to QuickBooks or Xero, or posted to the fuel ERP
- Approval needed for a price below contract or a credit over a set amount (e.g. $250)
Module 9
Customer portal and management reporting
Customers want the tank level and the balance; owners want run-outs and compliance at a glance.
- Portal: tank level or estimate, next delivery window, pre-buy balance, invoices, request a fill or a service call
- Reports: run-outs by month and cause, K-factor misses, leak checks done vs out-of-gas fills, service revenue per tech
- Compliance view: drivers with training due in 60 days, hoses and cargo tanks due, cylinders due
- Dealer-owned tanks at closed accounts waiting to be pulled
The AI agents, set up for propane and heating oil dealers
| Agent | When | What it does | What you get |
|---|---|---|---|
| Watcher agent | A delivery ticket closes with a zero gauge reading or a run-out flag and no linked leak check record | Checks whether a leak check or a 'shut and tagged' record exists for the site within the same visit, and whether a service job is already booked | An alert to the service manager and a leak check job created for the site, marked urgent, with the fill details attached |
| Dispatch agent | A route for tomorrow is built, or an odor or no-heat call comes in | Reads each driver's endorsements, hazmat training date and truck inspection status, or each tech's certifications and distance | A proposed driver per route or tech per call, with the reason anyone closer was skipped (training lapsed, no N endorsement, hose check overdue) |
| Calling agent | A customer calls after hours saying they are out of gas or smell gas | Finds the account, asks whether they smell gas, gives the shut-off and leave-the-house script for odor calls, and checks the last fill and tank estimate | An emergency service job or out-of-gas delivery booked with the caller's answers, and the on-call tech paged |
| Scheduler agent | Every Monday 6 a.m. in heating season | Reads run-outs last week, tanks forecast under reorder level, K-factor misses, leak checks open, drivers and hoses due | A weekly email to the owner: run-outs and their cause, forecast load by area, compliance items due in 30 days |
| Autopilot | Pre-buy and budget renewal season opens, or a budget account falls behind | Drafts the renewal or reminder from last year's gallons, plan and balance, for a person to approve before it sends | An email or text draft with last season's usage, the new plan price and a link to sign |
| Vision agent | A tech photographs a tank data plate, a cylinder collar or a regulator | Reads serial, manufacturer, water capacity, manufacture or requalification date and DOT specification | A filled tank or cylinder record for the tech to confirm, with a flag if the requalification date has passed |
Straight answers
Propane and heating oil delivery: FAQ
What software do propane and heating oil dealers use?
Most use a fuel-industry back office: ADD Systems (ADD Energy E3 with RAVEN in the trucks and Pegasus for service), PDI Propane and Commercial Fueling (the former Blue Cow Software), Cargas Energy or Energy-Force, with tank monitors such as Anova feeding levels in. Dealers with big HVAC departments sometimes add a general field service tool. Fieldproxy is one option when you want the service department, tank sets, leak checks and DOT records built around how your company runs.
Is a leak check required after a propane customer runs out of gas?
NFPA 54 8.2.3 (as quoted from the 2012 edition) requires a leak check immediately after gas is turned on into a system restored after an interruption of service. States write it into their own rules: Iowa requires the driver to shut and tag the service valve on an out-of-gas fill until a qualified person leak checks, and Mississippi requires a leak check on any interruption of service and records kept on file. Check your state's rule.
What should an out-of-gas leak check record include?
Start and end test pressures, how long the pressure held, the date and time, the gas in the tank, the result, and any appliances relit, listed one by one. LP Gas magazine's legal columnist warns that 'leak check passed' on a delivery ticket is not enough.
What is a K-factor?
In the convention Energy-Force uses, the number of degree days it takes a home to burn one gallon. Heating degree days are 65ยฐF minus the day's average temperature. The software adds daily use for water heaters and other appliances, estimates what is left, and recalculates the K-factor after each delivery. Some dealers state it the other way round (gallons per degree day), so check which your system uses.
What CDL endorsements does a propane bobtail driver need?
A bobtail is a tank vehicle (tanks over 119 gallons each, 1,000 gallons or more in total) carrying hazardous materials, so the driver needs the N tank and H hazmat endorsements, shown as X when combined, per 49 CFR 383.5 and 383.153 (see the rules above). Hazmat employee training is also required within 90 days of hire and every three years.
What replaced CETP?
PERC's Education Program (PEP). Per New Jersey's DCA, CETP 1.0, 2.2 and 2.4 were phased out through 2025 and replaced by PEP learning paths with on-the-job worksheets signed by a recognized field trainer. Some states, like New Jersey, still name CETP modules in their rules, so check what your state accepts.
How often must bobtail hoses and cargo tanks be inspected?
Delivery hoses and piping are visually inspected every calendar month in service (49 CFR 180.416). MC 331 cargo tanks get an external visual inspection and leakage test every year and an internal visual inspection and pressure test every 5 years (49 CFR 180.407), with a 10-year option for some small dedicated propane tanks.
How far must a propane tank be from a house?
It depends on size and your adopted NFPA 58 edition. Larimer County, Colorado summarizes 10 feet from a structure for 125 to 500 gallon aboveground tanks and 25 feet from buildings and property lines for 501 to 2,000 gallons, with relief valve discharge at least 5 feet from openings below it. Confirm with your authority having jurisdiction.
What does Massachusetts require on oil tanks?
Under M.G.L. c. 148, s. 38J, 1 to 4 unit homes whose oil lines touch the floor or ground need a sleeved supply line or an oil safety valve at the tank, certified by a licensed oil burner technician. Lines upgraded on or after 1 Jan 1990 to 527 CMR are exempt.
How many homes heat with propane and heating oil?
EIA's 2026 to 2027 Winter Fuels Outlook counts about 6.36 million US households heating mainly with propane and 4.13 million with heating oil, about 3.39 million of those oil homes in the Northeast. It projects heating oil spending up about 21 percent this winter and propane down about 3 percent.
Related guides
All sources on this page (37)
- source: Oil & Energy Online, Test for leaks when propane service is interrupted (quotes NFPA 54 8.2.3, 2014)
- source: Iowa Administrative Code 661-226.5 (pressure testing, leak check, out-of-gas start-up procedure)
- source: 49 CFR 172.704, Hazmat employee training requirements (via Cornell LII)
- source: 49 CFR 180.416, Discharge system inspection and maintenance for cargo tanks (via Cornell LII)
- source: LP Gas magazine, John McCoy, Distinction exists between placing gas system into service, in operation (2013)
- source: Mississippi 19 Miss. Code R. 7-14.04, Leak check procedures and requirements (via Cornell LII)
- source: LP Gas magazine, John McCoy, Servicing out-of-gas calls (2020)
- source: LP Gas magazine, Benny Gay (ThompsonGas), Complete thorough system leak checks (2023)
- source: 49 CFR 383.153, CDL endorsement codes H, N and X (via Cornell LII)
- source: 49 CFR 180.407, Cargo tank test and inspection intervals (via Cornell LII)
- source: New Jersey DCA, LP-Gas education and training memo: CETP to PEP transition (2025, updated 2 Jan 2026)
- source: Utah State Fire Marshal, LP-Gas basic filling procedures, general information
- source: National Oilheat Research Alliance (NORA), Technician certification program
- source: Massachusetts General Laws c. 148, s. 38J, oil safety valve or sleeved supply line (via Onecle)
- source: Energy-Force Help Center, K-factors and degree days basics
- source: Larimer County, Colorado, Liquid propane: general requirements (setbacks and relief valve discharge)
- source: 49 CFR 383.5, Definitions (tank vehicle) (via Cornell LII)
- source: 49 CFR 180.209, Requalification of specification cylinders (via Cornell LII)
- source: US EIA, Winter Fuels Outlook 2026 to 2027 (Short-Term Energy Outlook supplement)
- source: ADD Systems, ADD Energy E3, RAVEN and Pegasus
- source: PDI Technologies, PDI Propane and Commercial Fueling
- source: PDI Technologies, Stringer Oil and LP Gas case study (legacy Blue Cow Ignite)
- source: LP Gas magazine, PDI Technologies acquires Blue Cow Software (15 Feb 2023)
- source: Cargas, Cargas acquires Silverline's MyFuelPortal (9 Feb 2026)
- source: MFA Oil Bottom Line, BPLP division to transition to Energy-Force (2020)
- source: Anova, Universal Tank Monitor product page
Run propane and heating oil dealers work the way it actually runs.
A 30-minute call. We set up one of your real jobs in Fieldproxy so you can judge it on your own work.